BS EN ISO 25745-1:2012
$142.49
Energy performance of lifts, escalators and moving walks – Energy measurement and verification
Published By | Publication Date | Number of Pages |
BSI | 2012 | 26 |
1.1 General
This part of ISO 25745 specifies:
-
methods of measuring actual energy consumption of lifts, escalators and moving walks on a single unit basis;
-
methods of carrying out periodic energy verification checks on lifts, escalators and moving walks in operation.
This part of ISO 25745 only considers the energy performance during the operational portion of the life cycle of the lifts, escalators or moving walks.
1.2 Lifts
For lifts, this part of ISO 25745 does not cover energy aspects, such as:
-
hoistway lighting;
-
heating and cooling equipment in the lift car;
-
machine room lighting;
-
machine room heating, ventilation and air conditioning;
-
non-lift, display systems, closed circuit television security cameras, etc.;
-
non-lift, monitoring systems (building management systems, etc.);
-
the effect of lift group dispatching on energy consumption;
-
consumption through the power sockets.
1.3 Escalators and moving walks
For escalators and moving walks, this part of ISO 25745 covers energy aspects of the ancillary equipment, such as:
-
lighting with the exception of comb plate lighting and step gap lighting and traffic light;
-
cooling and heating;
-
alarm devices and emergency battery supplies equipment, etc.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | Foreword |
7 | Introduction |
9 | 1 Scope 1.1 General 1.2 Lifts 1.3 Escalators and moving walks 2 Terms and definitions |
11 | 3 Measurement and verification of lift, escalator and moving walk energy usage 3.1 General |
12 | 3.2 Lift energy measurements or escalator and moving walk power measurements 3.3 Lift, escalator and moving walk energy verification check |
13 | 3.4 Multiple lift, escalator and moving walk installations 4 Measurement procedures for a lift installation 4.1 Preliminaries |
14 | 4.2 Procedures for the energy measurements |
15 | 4.3 Procedures for the energy verification check |
17 | 5 Measurement procedures for an escalator or moving walk installation 5.1 Preliminaries 5.2 Procedures for power measurement |
18 | 5.3 Procedures for the power verification check 6 Reporting 6.1 General information |
19 | 6.2 Lift reporting 6.3 Lift energy usage verification check |
20 | 6.4 Escalator and moving walk energy reporting 6.5 Escalator and moving walk energy verification check reporting |
21 | Annex A (informative) Measuring instrument coupling points |
23 | Bibliography |