BS IEC 63145-20-20:2019
$142.49
Eyewear display – Fundamental measurement methods. Image quality
Published By | Publication Date | Number of Pages |
BSI | 2019 | 30 |
IEC 63145-20-20:2019 (E) specifies the standard measurement conditions and measurement methods for determining the image quality of eyewear displays. This document is applicable to non-see-through type (virtual reality â??VRâ?? goggle) and see-through type (augmented reality â??ARâ?? glasses) eyewear displays using virtual image optics. Contact-lens type displays and retina direct projection displays are out of the scope of this document.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
4 | CONTENTS |
6 | FOREWORD |
8 | 1 Scope 2 Normative references 3 Terms, definitions, abbreviated terms and letter symbols 3.1 Terms and definitions |
9 | 3.2 Abbreviated terms 3.3 Letter symbols (quantity symbols/unit symbols) 4 Standard measurement conditions 4.1 Standard environmental conditions 4.2 Power supply Table 1 – Letter symbols (symbols for quantities, and units) |
10 | 4.3 Warm-up time 4.4 Dark room conditions 5 Measurement systems 5.1 Standard coordinate system |
11 | 5.2 Measurement equipment 5.2.1 Light measuring device (LMD) Figures Figure 1 – Spherical coordinate system Figure 2 – Three-dimensional Cartesian coordinate system |
12 | Figure 3 – Example of LMD structure |
13 | 5.2.2 Stage conditions 5.2.3 Setup conditions |
14 | Figure 4 – Examples of measurement setup |
15 | 5.3 Test patterns 5.3.1 General 5.3.2 Checkerboard pattern 5.3.3 Solid colour patterns 5.3.4 Test patterns for Michelson contrast Figure 5 – Example of 5 x 5 checkerboard pattern |
16 | 5.4 Measurement points Figure 6 – Example of Michelson contrast test pattern Figure 7 – Measuring points for the centre- and multi-point measurement |
17 | 6 Measurement methods for image quality 6.1 General 6.2 Preparation 6.3 Distortion 6.3.1 General |
18 | 6.3.2 Procedure |
19 | 6.3.3 Calculation |
20 | 6.3.4 Report 6.4 Colour registration error 6.4.1 General 6.4.2 Procedure |
21 | 6.4.3 Calculation 6.4.4 Report 6.5 Michelson contrast 6.5.1 General 6.5.2 Procedure |
22 | 6.5.3 Calculation 6.5.4 Report 6.6 Focal distance (dioptre) 6.6.1 General |
23 | 6.6.2 Procedure |
24 | 6.6.3 Calculation 6.6.4 Report 6.7 FOV based on Michelson contrast 6.7.1 General 6.7.2 Procedure |
25 | 6.7.3 Calculation 6.7.4 Report 6.8 Eye-box based on Michelson contrast 6.8.1 General 6.8.2 Procedure |
26 | 6.8.3 Calculation |
27 | 6.8.4 Report |
28 | Bibliography |