BS IEC/IEEE 62582-4:2022 – TC 2023

$217.84

Tracked Changes. Nuclear power plants. Instrumentation and control important to safety. Electrical equipment condition monitoring methods – Oxidation induction techniques

Published By Publication Date Number of Pages
BSI 2023 76
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
44 undefined
46 Blank Page
47 English
CONTENTS
49 FOREWORD
52 INTRODUCTION
54 1 Scope
2 Normative references
3 Terms and definitions
55 4 Abbreviated terms and acronyms
5 General description
6 Applicability and reproducibility
56 7 Measurement procedure
7.1 Stabilisation of the polymeric materials
7.2 Sampling
7.2.1 General
7.2.2 Sample requirements
7.2.3 Precautions
57 7.3 Sample preparation
7.4 Instrumentation
7.5 Calibration
7.6 OIT measurement method
7.6.1 Measurement procedure
58 7.6.2 Temperature profile
Figure 1 – OIT measurement – Schematic of temperature and gas profile and corresponding heat flow
59 7.6.3 Gas flow
7.6.4 Determining the value of oxidation onset
Figures
Figure 2 – Schematic showing the types of baselines (flat, sloping, endothermic dip, melting endotherm) observed for OIT and OITP measurements
60 7.6.5 Reporting
Figure 3 – Schematic showing definition of onset value for OIT and OITP measurements
61 7.7 OITP measurement method
7.7.1 Measurement procedure
7.7.2 Temperature profile
7.7.3 Gas flow
Figure 4 – Schematic of the temperature for OITP measurements and the corresponding heat flow
62 7.7.4 Determining the value of oxidation onset
7.7.5 Reporting
64 Annex A (informative) Interpretation of thermogram
A.1 Interpretation of OIT thermograms
Figure A.1 – Example of an OIT plot with clear baseline and onset
65 Figure A.2 – Example of OIT plot with multiple onsets
66 Figure A.3 – Example of OIT plot where the baseline is difficult to define
Figure A.4 – Example of OIT plot where heat flow is too lowto use standard 0,1 W∙g–1 threshold
67 A.2 Interpretation of OITP thermograms
Figure A.5 – Example of an OITP plot with a well-defined baseline and onset
68 Figure A.6 – Example of an OITP plot for a semi-crystalline material showing a melting endotherm prior to the oxidation onset
Figure A.7 – Example of an OITP plot showing an endothermic dip immediately prior to the oxidation onset
69 Annex B (informative) Example of a measurement report from OITP and OIT
B.1 OITP measurements
Tables
Table B.1 – Example of a measurement report from OITP
70 Figure B.1 – Example of OITP test plot
71 B.2 OIT measurements
Table B.2 – Example of a measurement report from OIT
72 Figure B.2 – Example of OIT test plot
73 Annex C (informative) Influence of set temperature on the OIT value
Figure C.1 – Example of the influence of set temperature on the OIT value
74 Bibliography
BS IEC/IEEE 62582-4:2022 - TC 2023
$217.84