BS ISO 1496-2:2018 – TC:2020 Edition
$258.95
Tracked Changes. Series 1 freight containers. Specification and testing – Thermal containers
Published By | Publication Date | Number of Pages |
BSI | 2020 | 146 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
94 | National foreword |
99 | Foreword |
101 | 1 Scope 2 Normative references 3 Terms and definitions |
103 | 4 Classification 5 Marking 6 Dimensions and ratings 6.1 External dimensions |
104 | 6.2 Internal dimensions 6.3 Ratings |
105 | 7 Design requirements 7.1 General |
106 | 7.2 Corner fittings 7.3 Base structure |
107 | 7.4 End structure 7.5 Side wall structure 7.6 Walls 7.7 Door opening 7.8 Sanitary and taint-free requirements 7.9 Requirements for optional features 7.9.1 Fork-lift pockets |
108 | 7.9.2 Gooseneck tunnels 7.9.3 Drains 7.9.4 Water connections 7.9.5 Picture frames 7.9.6 Modified/controlled atmospheres 7.9.7 Fresh air ventilation control 7.9.8 Humidity control |
109 | 7.9.9 Load line 7.9.10 Floor 7.9.11 Air circulation 8 Testing 8.1 General |
110 | 8.2 Test No. 13 — Airtightness test 8.2.1 General |
111 | 8.2.2 Procedure 8.2.3 Requirements 8.3 Test No. 14 — Heat leakage test 8.3.1 General |
112 | 8.3.2 Procedure |
114 | 8.3.3 Heat leakage calculation 8.3.4 Requirements 8.4 Test No. 15 a) — Test of the performance of a thermal container under refrigeration by a mechanical refrigeration unit (MRU) 8.4.1 General |
115 | 8.4.2 Test conditions 8.4.3 Test procedure 8.4.4 Requirements |
116 | 8.5 Test No. 15 b) — Functional test of a thermal container at high ambient temperatures while being cooled by a mechanical refrigeration unit (MRU) 8.5.1 General 8.5.2 The thermal container shall be equipped with instruments for the measurement of: 8.5.3 Test conditions 8.5.4 Test procedure |
117 | 8.5.5 Requirements 8.6 Test No. 15 c) — Energy consumption of a thermal container at defined ambient temperatures while being cooled by a mechanical refrigeration unit (MRU) 8.6.1 General 8.6.2 The thermal container shall be equipped with instruments for the measurement of: 8.6.3 Test conditions |
118 | 8.6.4 Test procedure 8.6.5 Requirements 8.7 Test No. 16 — Strength of mounting devices for removable equipment (where fitted) 8.7.1 General 8.7.2 Test No. 16 a) — Vertical loading |
119 | 8.7.3 Test No. 16 b) — Horizontal loading 9 Electrical aspects of thermal containers 9.1 General |
120 | 9.2 General requirements for standard voltage equipment |
121 | 9.3 Remote condition monitoring |
122 | Annex A (normative) Requirements for cooling water connections |
125 | Annex B (informative) Picture frames |
127 | Annex C (normative) Air temperature measurement points |
129 | Annex D (normative) Phase connections to container plugs and sockets |
131 | Annex E (normative) Electric plug and socket, four-pin, 380/440 V, 50/60 Hz, 32 A |
135 | Annex F (informative) Electrical power supplies for thermal containers (9.2) |
136 | Annex G (normative) General requirements for 220 V and dual voltage equipment |
137 | Annex H (informative) MRU Nose Mounted Frame (Optional Backup Generator Set) |
138 | Annex I (informative) Ageing of polyurethane foam |
144 | Bibliography |