BS ISO 230-6:2002
$102.76
Test code for machine tools – Determination of positioning accuracy on body and face diagonals (Diagonal displacement tests)
Published By | Publication Date | Number of Pages |
BSI | 2002 | 16 |
This part of ISO 230 specifies diagonal displacement tests which allow estimation of the volumetric performance of a machine tool. Complete testing of the volumetric performance of a machine tool is a difficult and time-consuming process. Diagonal displacement tests reduce the time and cost associated with testing the volumetric performance.
A diagonal displacement test is not in itself a diagnostic test, although conclusions of a diagnostic nature may sometimes be possible from the results. In particular, when face diagonal tests are included, a direct measurement of the axes squareness is possible. Diagonal displacement tests on body diagonals may be supplemented by tests in the face diagonals, by tests parallel to the machine axes in accordance with ISO 230-2, or by the evaluation of the contouring performance in the three coordinate planes as defined in ISO 230-4.
Diagonal displacement tests may be used for acceptance purposes and as reassurance of machine performance where parameters of the test are used as comparison index.
PDF Catalog
PDF Pages | PDF Title |
---|---|
3 | TitlePage – Test code for machine tools�— |
5 | TableofContent – Contents Page |
6 | Foreword – Foreword |
7 | Scope – 1��� Scope NormativeReference – 2��� Normative references |
10 | Clause1 – 4��� Preliminary remarks Subclause2 – 4.1��� Measuring units Subclause2 – 4.2��� Reference to ISO�230-1 and ISO�230-2 |
11 | Subclause2 – 4.3��� Tests to be performed Subclause2 – 4.4��� Measuring instruments Subclause2 – 4.5��� Position of linear axes not under test Subclause2 – 4.6��� Measurement uncertainty Clause1 – 5��� Test procedure, parameters, set-up procedure Subclause2 – 5.1��� Test procedure Subclause2 – 5.2��� Target positions |
12 | Subclause2 – 5.3��� Measurements Subclause2 – 5.4��� Feed rate Subclause2 – 5.5��� Set-up procedure |
13 | Clause1 – 6��� Evaluation of results Clause1 – 7��� Points to be agreed between supplier/manufacturer and user Clause1 – 8��� Presentation of the results Subclause2 – 8.1��� Method of presentation |
14 | Subclause2 – 8.2��� Parameters |
15 | AnnexInformative – Set-up procedure for laser interferometer Clause1 – A.1��� General Clause1 – A.2��� Procedure |