BS ISO 23551-6:2021 – TC:2022 Edition
$186.33
Tracked Changes. Safety and control devices for gas burners and gas-burning appliances. Particular requirements – Thermoelectric flame supervision controls
Published By | Publication Date | Number of Pages |
BSI | 2022 | 62 |
This document specifies safety, constructional, and performance and testing requirements for thermoelectric flame supervision controls, energized by a thermocouple, intended for use with gas burners and gas-burning appliances, hereafter referred to as “ controls”.
This document applies to thermoelectric flame supervision controls for gas burners and gas-burning appliances of nominal connection size up to, and including DN 50, that can be used and tested independently of these appliances.
These thermoelectric flame supervision controls are suitable for fuel gases, such as natural gas, manufactured gas or liquefied petroleum gas (LPG) at inlet pressures up to and including 50 kPa. It is not applicable to corrosive and waste gases.
This document covers type testing only.
This document is not applicable to:
-
the thermocouple; and
-
controls which use auxiliary energy (e.g. electrical energy supplied externally).
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 30451996 |
35 | A-30401686 |
36 | National foreword |
41 | Foreword |
42 | Introduction |
43 | 1 Scope 2 Normative references 3 Terms and definitions |
44 | 4 Classification 4.1 Classes of controls 4.2 Groups of controls 4.3 Types of DC supplied controls 4.4 Classes of control functions |
45 | 5 Test conditions and tolerances 6 Construction 6.1 General 6.2 Construction requirements 6.2.1 Appearance 6.2.2 Holes 6.2.3 Breather holes 6.2.4 Vent limiter 6.2.5 Screwed fastenings 6.2.6 Moving parts 6.2.7 Sealing caps 6.2.8 Disassembling and assembling for servicing and/or adjustment for controls 6.2.9 Auxiliary channels and orifices 6.2.10 Pre-setting device |
46 | 6.3 Materials 6.4 Connections 6.4.1 General 6.4.2 Connection sizes 6.4.3 Connection types 6.4.4 Threads 6.4.5 Union joints 6.4.6 Flanges 6.4.7 Compression fittings 6.4.8 Flare connections 6.4.9 Nipples for pressure tests 6.4.10 Strainers 6.4.11 Gas connections by GQC 6.5 Gas controls employing electrical components in the gas way |
47 | 7 Performance 7.1 General 7.2 Leak-tightness 7.2.1 General 7.2.2 Requirements 7.2.3 Test |
48 | 7.3 Torsion and bending 7.4 Rated flow rate 7.5 Durability 7.6 Functional requirements 7.6.1 Operating torque and force |
49 | 7.6.2 Interlocks 7.6.3 Sealing force |
50 | 7.6.4 Closing current 7.7 Endurance 7.7.1 Requirements 7.7.2 Endurance test |
51 | 7.8 Vibration test 8 Electrical equipment 9 Electromagnetic compatibility (EMC) 10 Marking, installation and operation instructions 10.1 Marking |
52 | 10.2 Installation and operating instructions 10.3 Warning notice |
53 | Annex A (informative) Leak-tightness test — Volumetric method |
54 | Annex B (informative) Leak-tightness test — Pressure-loss method |
55 | Annex C (normative) Conversion of pressure loss into leakage rate |
56 | Annex D (normative) Gas quick connector (GQC) |
57 | Annex E (normative) Elastomers/requirements resistance to lubricants and gas |
58 | Annex F (normative) Specific regional requirements in European countries |
59 | Annex G (normative) Specific regional requirements in Canada and USA |
60 | Annex H (normative) Specific regional requirements in Japan |
61 | Annex I (informative) Types of flame supervision controls |