Shopping Cart

No products in the cart.

BS ISO 4266-6:2002

$102.76

Petroleum and liquid petroleum products. Measurement of level and temperature in storage tanks by automatic methods – Measurement of temperature in pressurized storage tanks (non-refrigerated)

Published By Publication Date Number of Pages
BSI 2002 20
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of ISO 4266 gives guidance on the selection, accuracy, installation, commissioning, calibration and verification of automatic tank thermometers (ATTs) in fiscal/custody transfer applications in which the ATT is used for measuring the temperature of petroleum and liquid petroleum products, stored in pressurized storage tanks.

This part of ISO 4266 is not applicable to the measurement of temperature in caverns or in refrigerated storage tanks.

PDF Catalog

PDF Pages PDF Title
3 TitlePage – Petroleum and liquid petroleum products�— Measurement of level and temperature in sto…
5 TableofContent – Contents Page
7 Foreword – Foreword
9 Scope – 1��� Scope
NormativeReference – 2��� Normative reference
10 Clause1 – 4��� Precautions
Subclause2 – 4.1��� Safety precautions
Subclause2 – 4.2��� Equipment precautions
UntitledSubclause3 – 4.2.1��� All ATT equipment should be capable of withstanding the pressure, t…
UntitledSubclause3 – 4.2.2��� ATTs should be certified for use in the hazardous-area classificati…
UntitledSubclause3 – 4.2.3��� Measures should be taken to ensure that all exposed metal parts of …
UntitledSubclause3 – 4.2.4��� All parts of the ATT in contact with the product or its vapour shou…
UntitledSubclause3 – 4.2.5��� All ATT equipment should be maintained in safe operating condition …
Subclause2 – 4.3��� General precautions
UntitledSubclause3 – 4.3.1��� The general precautions given in
11 UntitledSubclause3 – 4.3.2��� Tank levels should be measured at the same time as the tank tempera…
UntitledSubclause3 – 4.3.3��� Temperatures measured for bulk transfer should be recorded when the…
UntitledSubclause3 – 4.3.4��� The same general procedures should be used to measure a tank temper…
UntitledSubclause3 – 4.3.5��� ATTs should provide security to prevent unauthorized adjustment or …
UntitledSubclause3 – 4.3.6��� The design and installation of ATTs may be subject to the approval …
Clause1 – 5��� Accuracy
Subclause2 – 5.1��� General
Subclause2 – 5.2��� Intrinsic error of ATTs
Subclause2 – 5.3��� Calibration prior to installation
Subclause3 – 5.3.1��� General
Subclause3 – 5.3.2��� ATT calibrated as a system
12 Subclause3 – 5.3.3��� AT�T calibrated by components
Subclause3 – 5.3.4��� Multiple-point ATTs
Subclause3 – 5.3.5��� Uncertainty of the reference
Subclause2 – 5.4��� Error caused by installation and operating conditions
Subclause2 – 5.5��� Overall accuracy
Subclause3 – 5.5.1��� General
Subclause3 – 5.5.2��� Use of AT�T for fiscal/custody transfer purposes
13 Clause1 – 6��� Selection of ATTs
Subclause2 – 6.1��� General
Subclause2 – 6.2��� ATTs for fiscal/custody transfer purpose
Clause1 – 7��� Description of ATT equipment
Subclause2 – 7.1��� Introduction
14 Subclause2 – 7.2��� Electrical temperature elements
Subclause3 – 7.2.1��� Resistance temperature detectors
Subclause3 – 7.2.2��� Other temperature elements
Clause1 – 8��� Installation of ATTs
Subclause2 – 8.1��� General
Subclause2 – 8.2��� Single-point (spot) temperature elements
Subclause2 – 8.3��� Multiple-point temperature elements
15 Subclause2 – 8.4��� Moveable spot temperature element
Subclause2 – 8.5��� Other methods
Subclause2 – 8.6��� Thermowells for electronic temperature elements
Subclause2 – 8.7��� Thermowells for verification purposes
Clause1 – 9��� Calibration and field verification of ATTs
Subclause2 – 9.1��� Introduction
16 Subclause2 – 9.2��� Calibration of single-point temperature element ATTs used for fiscal/custody …
Subclause3 – 9.2.1��� Calibration prior to installation
Subclause3 – 9.2.2��� Initial field verification
Subclause4 – 9.2.2.1��� Verification by components
Subclause5 – 9.2.2.1.1��� Temperature element
Subclause5 – 9.2.2.1.2��� Temperature transmitter
Subclause4 – 9.2.2.2��� Verification as a system
17 Subclause2 – 9.3��� Calibration of upper, middle and lower or multiple-point ATTs
Subclause3 – 9.3.1��� Calibration prior to installation
Subclause3 – 9.3.2��� Initial field verification
Subclause4 – 9.3.2.1��� Verification by components
Subclause5 – 9.3.2.1.1��� Temperature element
Subclause5 – 9.3.2.1.2��� Temperature transmitter
Subclause4 – 9.3.2.2��� Verification as a system
18 Subclause2 – 9.4��� Subsequent verification of ATTs
Subclause3 – 9.4.1��� General
Subclause3 – 9.4.2��� Frequency of subsequent verification
Subclause3 – 9.4.3��� Record keeping
Clause1 – 10��� Data communication and receiving
19 Bibliography – Bibliography
BS ISO 4266-6:2002
$102.76