BS ISO/IEC 14165-147:2021
$198.66
Information technology. Fibre channel – Physical interfaces. 7 (FC-PI-7)
Published By | Publication Date | Number of Pages |
BSI | 2021 | 62 |
This standard describes the physical interface portions of high performance optical link variants that support the higher level Fibre Channel protocols including FC-FS-4 (reference [1]) and FC-FS-5 (reference [2]).
FC-PI-7 specifies 64GFC. 32GFC and 128GFC are described in FC-PI-6 (reference [3]) and FC-PI-6P (reference [4]), respectively.16GFC, 8GFC and 4GFC are described in FC-PI-5 (reference [5]).
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
16 | 1 Scope 2 Normative references 2.1 General 2.2 Normative references 2.2.1 Approved references |
17 | 2.2.2 References under development |
18 | 3 Definitions and conventions 3.1 Definitions |
22 | 3.2 Editorial conventions 3.2.1 Conventions |
23 | 3.2.2 Keywords 3.2.3 Abbreviations, acronyms, and symbols |
24 | 3.2.3.1 Acronyms and other abbreviations |
25 | 3.2.3.2 Signaling rate abbreviations |
26 | 4 FC-PI-7 functional characteristics 4.1 General characteristics 4.2 Compliance test points |
28 | a) Physical point-to-point data links. b) Signal requirements shall be met under the most extreme specified conditions of system noise and with the minimum compliant quality signal launched at upstream interoperability points. c) All users are cautioned that detailed specifications shall take into account end-of-life worst case values (e.g., manufacturing, temperature, power supply). 4.3 FC-0 functions 4.3.1 Transmitter functions 4.3.2 Receiver functions |
29 | 4.4 Limitations on invalid code 4.5 Receiver stabilization time 4.6 Loss of signal (Rx_LOS) function 4.7 Speed agile ports that support speed negotiation and training a) The transmitter or the repeater shall be capable of switching from compliant operation at one speed to compliant operation at a new speed within the time periods determined in clause 8 of FC-FS-5 (reference [2]).The FC-1 level shall attain Transmi… b) The transmitter and receiver shall be capable of operating at different speeds at the same time during speed negotiation. c) The transmit training signal used for speed negotiation for 64GFC is defined in FC-FS-5 (reference [2]). 4.8 Transmission codes 4.9 Frame scrambling and emission lowering protocol |
30 | 4.10 Forward error correction (FEC) 4.11 Bit error ratio per link locations and segments |
31 | 4.12 FC-PI-7 variants |
32 | 5 Optical interface specification 5.1 TxRx connections 5.2 Laser safety issues 5.3 Optical signal modulation format |
33 | 5.4 SM data links 5.4.1 SM general information 5.4.2 SM optical output interface 5.4.3 SM optical input interface 5.4.4 Transmitter transition time 5.4.5 TDECQ Test 5.4.6 SECQ Measurement 5.4.7 SRS Test |
35 | 5.5 MM data links 5.5.1 MM general information 5.5.2 MM optical output interface 5.5.3 MM optical input interface 5.5.4 Transmitter transition time |
36 | 5.5.5 TDECQ Test 5.5.6 SECQ Measurement 5.5.7 SRS Test |
38 | 5.6 SM Cable Plant 5.6.1 Cable plant overview 5.6.2 Optical Return Loss |
39 | 5.6.3 Connector and Splices 5.7 MM Cable Plant 5.7.1 Cable plant overview 5.7.2 Optical Return Loss 5.7.3 Connector and Splices |
40 | 6 Electrical interface specification – single lane segments 6.1 General electrical characteristics 6.2 Compliance test point definitions 6.2.1 Test method |
41 | 6.2.2 Host test points 6.2.3 Module test points |
42 | 6.2.4 Host input calibration point |
43 | 6.2.5 Module input calibration point |
44 | 6.3 Transmitted signal characteristics |
45 | 6.4 Receive signal characteristics |
46 | 6.5 Differential return loss and mode conversion requirements 6.5.1 Differential return loss 6.5.2 Common to differential-mode and differential to common-mode conversion |
48 | 7 Backplane variant, 64GFC-EA 7.1 TxRx Connections 7.2 Test Fixtures |
50 | 7.3 Transmitter specification |
52 | 7.4 Receiver specification 7.4.1 Receiver input return loss |
53 | 7.4.2 Receiver interference tolerance |
54 | 7.4.3 Receiver jitter tolerance 7.5 Channel Specification 7.5.1 Channel Operating Margin |
56 | 7.5.2 Channel Return Loss 7.5.3 Channel AC coupling |
57 | Annex A (informative) Optical cable plant usage |
59 | Annex B (informative) Structured cabling environment B.1 Specification of operating distances B.2 Alternate connection loss operating distances |
60 | Annex C (informative) Electrical channel |