BS EN IEC 62909-3 Bi-directional grid connected power converters – Part 3. EMC requirements and test methods

Published By Publication Date Number of Pages
BSI 2023 56
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
8 FOREWORD
10 INTRODUCTION
11 1 Scope
2 Normative references
13 3 Terms, definitions
18 4 Classification of GCPCs
4.1 Division into classes
19 4.2 Information for users
5 Measurement and test setup
5.1 General
20 5.2 Configuration of test setups
5.2.1 General
5.2.2 Setups for immunity requirement test
5.2.2.1 General
5.2.2.2 Electrostatic discharge immunity test
5.2.2.3 Radiated, radio-frequency, electromagnetic field immunity test
21 5.2.2.4 Electrical fast transient/burst immunity test
5.2.2.5 Surge immunity test
5.2.2.6 Immunity to conducted disturbances, induced by radio-frequency fields
5.2.2.7 Voltage dips, short interruptions and voltage variations immunity test (≤ 16 A)
5.2.2.8 Voltage dips, short interruptions and voltage variations immunity test (> 16 A)
5.2.3 Setups for low frequency emission requirement test
5.2.3.1 Harmonics
5.2.3.2 Voltage fluctuations and flicker
5.2.4 Setups for high frequency emission requirement test
6 Operating conditions during testing
6.1 General
22 6.2 Operating conditions for immunity requirement test
6.2.1 Operating conditions for immunity requirement test for GCPC with EV section
6.3 Operating conditions for emission requirement test
6.3.1 Operating conditions for low frequency emission requirement test
6.3.2 Operating conditions for high frequency emission requirement test
23 6.3.3 Operating conditions for emission requirement test for GCPC with EV section
7 Immunity requirements
7.1 General
27 7.2 Performance criteria
28 8 Emission requirements
8.1 Low frequency range
29 8.2 High frequency range
8.2.1 Disturbance voltage limits at the AC power port (150 kHz to 30 MHz)
30 8.2.2 Disturbance voltage limits at the DC power port (150 kHz to 30 MHz)
31 8.2.3 Disturbance voltage limits at the CPT port (150 kHz to 30 MHz)
32 8.2.4 Disturbance voltage limits at the wired network port and the signal and control port (150 kHz to 30 MHz)
8.2.5 Radiated emission limits at Enclosure port (above 30 MHz)
33 8.2.5.1 GCPC with the EV section
8.2.5.2 GCPC without the EV section
35 8.2.6 Radiated emission limits at Enclosure port (above 1 GHz)
36 8.2.7 Radiated emission limits at Enclosure port (2kHz to 185kHz) with the EV section
8.2.8 Voltage transient disturbances with the EV section
9 Test results and test report
37 Annex A (informative) Examples of GCPC
A.1 General
A.2 Examples of GCPC within the scope of this document
38 A.3 Examples of GCPC where other standards apply
40 Annex B (informative) Overview of requirements
B.1 General
B.2 Immunity requirements
41 B.3 Conducted emission requirements
B.4 Radiated emission requirements
42 Annex C (normative) Example test setups
45 Annex D (informative) Radiated disturbance test for keyless entry
D.1 General
D.2 Test setup
D.3 Test method
46 D.4 Limits for radiated disturbances keyless entry (2 kHz to 185 kHz)
47 Annex E (informative) Termination of ports
E.1 General
E.2 Termination of communication lines – asymmetric artificial network (AAN)
E.2.1 General
E.2.2 Symmetric communication lines (e.g. CAN)
48 E.2.3 Coupling devices for PLC on power lines
49 E.2.4 PLC (technology) on control pilot
51 E.3 Coupling and termination devices for other communication and signalling lines
52 Annex F (normative) Voltage transient disturbances from DC charging equipment
54 Annex G (normative) Voltage surge test setup for DC charging EUT
55 Annex H (informative) Transient immunity test for DC charging EUT
56 Bibliography