BSI PD CLC/TR 50422:2013
$189.07
Guide for the application of the European Standard EN 50160
Published By | Publication Date | Number of Pages |
BSI | 2013 | 48 |
The aim of this Technical Report is to provide background information and explanations on EN 50160 with regard to the history of its development as well as to its correct application.
PDF Catalog
PDF Pages | PDF Title |
---|---|
8 | 1 Scope 2 Historical overview of the Standard and its development 2.1 Historical development |
11 | 2.2 Structure |
12 | 2.3 New versions of EN 50160. A move towards limits and requirements |
13 | 2.4 HV chapter |
14 | 3 The Standard 3.1 General |
15 | 3.2 Applicability |
17 | 3.3 Covered / Not covered phenomena |
18 | 3.4 Specific terms 3.4.1 General 3.4.2 Supply voltage 3.4.3 Supply terminal and other reference points |
19 | 3.4.4 Nominal voltage (Un) and declared voltage (Uc) |
20 | 3.5 “Measurement according to EN 50160” 3.6 Averaging times, observation periods |
21 | 3.7 PQ values & test methods 3.7.1 Probability factors |
22 | 3.7.2 Verification of compliance with EN 50160 |
23 | 3.8 Rapid voltage changes and flicker |
24 | 3.9 Voltage dips & swells classification tables 3.9.1 Voltage dips characteristics 3.9.2 Residual voltage (u) |
25 | 3.9.3 Duration (t) 3.9.4 Voltage-dips statistics |
26 | 3.9.5 Voltage-swells characteristics |
27 | 3.9.6 Transient overvoltages 3.10 Trends 4 Position of EN 50160 in the standards scenario 4.1 EMC & PQ. Relationship |
28 | 4.2 Position to other standards 4.2.1 EMC Standards |
30 | 4.2.2 Other product standards 4.2.3 EN 60038 |
31 | 4.2.4 EN 61000-4-30 |
32 | Annex A (informative) Distributed generation and its impact on the supply voltage |
34 | Annex B (informative) Voltage / current components in the frequency range 2 kHz – 150 kHz and its impact on the supply voltage |
37 | Annex C (informative) Overvoltages C.1 Temporary (power frequency) overvoltages between live conductors and earth C.1.1 General C.1.2 LV distribution systems C.1.3 MV distribution systems C.1.3.1 Introduction C.1.3.2 Overvoltages due to single line to earth faults C.1.3.3 Overvoltages due to ferroresonance C.1.3.3.1 Introduction |
38 | C.1.3.3.2 Open circuit condition C.1.3.3.3 Grounded voltage transformers in isolated neutral MV networks C.2 Transient overvoltages between live conductors and earth C.2.1 General C.2.2 LV distribution system C.2.2.1 General |
39 | C.2.2.2 Long duration surges (> 100 µs) C.2.2.3 Medium duration surges (1 µs to 100 µs) C.2.2.4 Short duration surges (< 1 µs) |
40 | C.2.3 MV distribution systems C.2.3.1 Long duration surges (> 100 µs) C.2.3.2 Medium duration surges 1 µs to 100 µs C.2.3.3 Short duration surges < 1 µs C.3 Temporary (power frequency) overvoltages between live conductors |
41 | Annex D (informative) Abbreviations |