BSI PD IEC TS 63070:2019

$142.49

Ultrasonics. Field characterization. Infrared imaging techniques for determining temperature elevation in tissue-mimicking material and at the radiation surface of a transducer in still air

Published By Publication Date Number of Pages
BSI 2019 30
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document is applicable to ultrasonic equipment designed for the medical field of application. It covers both diagnostic and therapeutic (physiotherapy and HITU) equipment.

This document describes transducer evaluation by the infrared imaging technique using a split TMM-phantom for qualitative and quantitative estimation of temperature distributions in tissue-mimicking material, resulting from absorption of ultrasound and from heating of the transducer itself.

This document also describes a method to measure transducer-surface temperature, while the transducer is driven under the still-air condition.

NOTE 1 When the transducer is in contact with tissue-mimicking material, the heating of the transducer itself depends on the actual efficiency of the transducer, on the specific conditions for thermal transfer to or from the tissue-mimicking material, and on the transmitting/receiving electronic circuits, such as a switching circuit or pre-amplifier in some cases.

NOTE 2 The test objects specified in this document are for the measurement of temperature rise and not for the determination of thermal index, which is, by definition in IEC 62359:2010 and IEC 62359:2010/AMD1:2017, an algebraic combination of acoustical field quantities and therefore is not a physically measurable quantity.

PDF Catalog

PDF Pages PDF Title
2 undefined
4 CONTENTS
6 FOREWORD
8 INTRODUCTION
9 1 Scope
2 Normative references
10 3 Terms and definitions
4 Symbols and abbreviated terms
5 Methods of use
5.1 General
11 5.2 Consideration of perfusion
5.3 Effects of environment
6 IR-camera specifications
6.1 General
6.2 Test
6.3 Calibration
12 7 Phantom specification and construction
7.1 Split TMM specifications
7.2 Periodic validation
8 Measurement procedure
8.1 Split TMM setup
8.1.1 General
13 8.1.2 Emissivity
8.1.3 Procedure
14 8.2 Still-air setup
8.2.1 General
8.2.2 Emissivity
8.2.3 Procedure
9 Uncertainty determination
15 Annex A (informative) Measurement example using a split TMM setup
A.1 General
A.2 Measurement setups
16 Figures
Figure A.1 – Concept of measurement
17 Figure A.2 – Setups for thermal equilibrium and measurement
18 A.3 Procedures
19 A.4 Data analysis
20 A.5 Improved split TMM-phantom
Figure A.3 – Analysis of thermal image
Table A.1 – Results of measurement
21 Figure A.4 – Improved split TMM phantom
22 Annex B (informative) Measurement procedure under the condition of still air
B.1 General
B.2 Measurement setups
B.3 Procedures
23 Figure B.1 – Example of a measurement setup for the transducer surface-temperaturetest in still air using an infrared camera
24 Figure B.2 – Flow chart of the transducer surface-temperature testin still air using an infrared camera
25 Annex C (informative) Guidance on uncertainty determination
27 Bibliography