Shopping Cart

No products in the cart.

ICC SignificantChangestotheIRC 2015

$30.20

Significant Changes to the International Residential Code, 2015 Edition

Published By Publication Date Number of Pages
ICC 2015 353
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Gain full access to the most critical updates in the International Residential Code®, including the real-world application of those changes and how they originated — all in a single, easy-to-use resource. SIGNIFICANT CHANGES TO THE INTERNATIONAL RESIDENTIAL CODE® 2015 Edition provides a comprehensive analysis of significant changes since the 2012 IRC®, offering key insights into its contents and implications. Coverage includes changes made to building, energy, mechanical, fuel gas, plumbing, and electrical provisions. Each change analysis features the affected code sections and identifies the change with strikethroughs and underlines to show modifications to the existing language. Each change is accompanied by a quick summary, detailed illustrations, and discussion of its significance, which brings the technical jargon of the code to life in a real-world setting. The attention to detail, logical organization, and thorough yet concise coverage found in this resource make it an ideal tool for transitioning from the 2012 IRC®.

PDF Catalog

PDF Pages PDF Title
1 SIGNIFICANT CHANGES TO THE INTERNATIONAL RESIDENTIAL CODE
2 SIGNIFICANT CHANGES TO THE INTERNATIONAL RESIDENTIAL CODE TITLE PAGE
3 COPYRIGHT
4 CONTENTS
10 PREFACE
14 PART 1 ADMINISTRATION CHAPTERS 1 AND 2
15 R101.2, R202 SCOPE-ACCESSORY STRUCTURES
SECTION R202 DEFINITIONS
FIGURE: ACCESSORY BUILDING
17 R104.11 ALTERNATIVE MATERIALS, DESIGN, AND METHODS OF CONSTRUCTION AND EQUIPMENT
FIGURE: ALTERNATIVE PRODUCT
18 R105.3.1.1 EXISTING BUILDINGS IN FLOOD HAZARD AREAS
R105.3.1.1 DETERMINATION OF SUBSTANTIALLY IMPROVED OR SUBSTANTIALLY DAMAGED EXISTING BUILDINGS IN FLOOD HAZARD AREAS
FIGURE: FLOOD-PRONE CONSTRUCTION
20 R106.1.4 INFORMATION FOR CONSTRUCTION IN FLOOD HAZARD AREAS
R106.1.4 INFORMATION FOR CONSTRUCTION IN FLOOD HAZARD AREAS
FIGURE: WAVE SCOUR OF A DWELLING FOUNDATION
22 PART 2 BUILDING PLANNING CHAPTER 3
24 TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
FIGURE: SPECIAL WIND REGION-COLUMBIA RIVER GORGE
25 R301.2 WIND DESIGN CRITERIA
FIGURE: HURRICANE-FORCE WINDS
SECTION R202 DEFINITIONS
R301.2.1 WIND DESIGN CRITERIA
R301.2.1.1 WIND LIMITATIONS AND WIND DESIGN REQUIRED
26 R301.2.1.3 WIND SPEED CONVERSION
TABLE R301.2.1.3 WIND SPEED CONVERSIONS
30 R301.2 WIND SPEED MAPS
FIGURE R301.2(4)A ULTIMATE DESIGN WIND SPEEDS
31 FIGURE R301.2(4)b REGIONS WHERE WIND DESIGN IS REQUIRED
32 FIGURE: COMPARISON OF WIND SPEED
33 TABLE R301.2(2) COMPONENT AND CLADDING LOADS
TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B
FIGURE: CLADDING DAMAGE
34 FIGURE: COMPONENT AND CLADDING PRESSURE ZONES
TABLE 3.1 COMPARISON OF ROOF ANGLE CATEGORIES
35 R301.2.1.1.1 SUNROOMS
FIGURE: SUNROOM
37 R301.2.1.2 PROTECTION OF OPENINGS IN WIND BORNE DEBRIS REGIONS
R3012.1.2 PROTECTION OF OPENINGS
FIGURE: WOOD STRUCTURAL PANELS PROTECTING WINDOWS FROM WIND-BORNE DEBRIS
R301.2.1.2.1 APPLICATION OF ASTM E 1996
2.2 ASCE STANDARD
FIGURE: POLY PANELS PROTECTING WINDOWS FROM WIND-BORNE DEBRIS
39 R301.2.1.4 WIND EXPOSURE CATEGORY
R301.2.1.4 EXPOSURE CATEGORY
FIGURE: WIND EXPOSURE CATEGORY C AREA
40 FIGURE: PREVIOUSLY CONSIDERED IN WIND EXPOSURE CATEGORY A, LARGE CITY CENTERS ARE NOW CLASSIFIED AS WIND EXPOSURE CATEGORY B
42 TABLE R301.2.1.5.1 MODIFICATIONS FOR TOPOGRAPHIC WIND EFFECTS
TABLE R301.2.1.5.1 ULTIMATE DESIGN WIND SPEED MODIFICATION FOR TOPOGRAPHIC WIND EFFECT
FIGURE: DWELLINGS ON TOE OF SLOPE
43 R301.2.4 FLOODPLAIN CONSTRUCTION
R301.2.4 FLOODPLAIN CONSTRUCTION
R301.2.4.1 ALTERNATIVE PROVISIONS
FIGURE: HOUSES IN A FLOODPLAIN
45 R301.3 STORY HEIGHT
46 FIGURE: STORY HEIGHT
48 R302.1 EXTERIOR WALLS
TABLE R302.1 (1) EXTERIOR WALLS
49 TABLE R302.1(2) EXTERIOR WALLS-DWELLINGS WITH FIRE SPRINKLERS
FIGURE: FIRE RESISTANCE RATING IS NOT REQUIRED FOR ROOF EAVE PROJECTIONS WHEN FIREBLOCKING IS INSTALLED
51 TABLE 3-2 FIRE RESISTANCE OF ROOF OVERHANG PROJECTIONS
52 R302.2 TOWNHOUSE SEPARATION
R302.2 TOWNHOUSES
FIGURE: COMMON WALLS SEPARATING TOWNHOUSES
53 R302.2.4 STRUCTURAL INDEPENDENCE
55 R302.13 FIRE PROTECTION OF FLOORS
R302.13 FIRE PROTECTION OF FLOORS
FIGURE: FIRE PROTECTION OF FLOORS
56 FIGURE: OPEN WEB FLOOR TRUSSES REQUIRING MEMBRANCE PROTECTION ON THE UNDERSIDE
57 R303.7, R303.8 STAIRWAY ILLUMINATION
FIGURE: STAIRWAY ILLUMINATION
58 R303.7 INTERIOR STAIRWAY ILLUMINATION
R303.8 EXTERIOR STAIRWAY ILLUMINATION
59 R304.1 MINIMUM HABITABLE ROOM AREA
R304.1 MINIMUM AREA
FIGURE: SMALL DWELLING COMPLYING WITH MINIMUM AREA REQUIREMENTS
61 R305 CEILING HEIGHT
SECTION R305 CEILING HEIGHT
R305.1 MINIMUM HEIGHT
FIGURE: CEILING HEIGHT
62 R305.1.1 BASEMENTS
64 R308.4.2 GLAZING ADJACENT TO DOORS
R308.4.2 GLAZING ADJACENT TO DOORS
FIGURE: GLAZING IN WINDOWS ADJACENT AND PERPENDICULAR TO DOOR
FIGURE: WINDOWS ADJACENT AND PERPENDICULAR TO DOOR
66 R308.4.5 GLAZING AND WET SURFACES
FIGURE: GLAZING FACING SHOWER
68 R308.4.7 GLAZING ADJACENT TO THE BOTTOM STAIR LANDING
FIGURE: GLAZING ADJACENT TO BOTTOM STAIR LANDING
69 R310 EMERGENCY ESCAPE AND RESCUE OPENINGS
SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS
R310.1 EMERGENCY ESCAPE AND RESCUE OPENING REQUIRED
R310.1.1 OPERATIONAL CONSTRAINTS AND OPENING CONTROL DEVICES
R310.2 EMERGENCY ESCAPE AND RESCUE OPENINGS
R310.2.1 MINIMUM OPENING AREA
R310.2.2 WINDOW SILL HEIGHT
R310.2.3 WINDOW WELLS
70 R310.2.3.1 LADDER AND STEPS
FIGURE: TYPICAL USE OF PATIO DOORS AND WINDOWS AS EMERGENCY ESCAPE AND RESCUE OPENINGS
FIGURE: EMERGENCY ESCAPE AN DRESCUE WINDOWS
71 R310.2.3.2 DRAINAGE
R310.2.4 EMERGENCY ESCAPE AND RESCUE OPENINGS UNDER DECKS AND PORCHES
R310.3 EMERGENCY ESCAPE AND RESCUE DOORS
R310.3.1 MINIMUM DOOR OPENING SIZE
R310.3.2 BULKHEAD ENCLOSURES
R310.3.2.1 DRAINAGE
R310.4 BARS, GRILLES, COVERS, AND SCREENS
73 R310.5, R310.6 EMERGENCY ESCAPE AND RESCUE OPENINGS FOR ADDITIONS, ALTERATIONS AND REPAIRS
R310.5 DWELLING ADDITIONS
R310.6 ALTERATIONS OR REPAIRS OF EXISTING BASEMENTS
FIGURE: A BASEMENT ADDITION DOES NOT REQUIRE AN EMERGENCY ESCAPE AND RESCUE OPENING IF ACCESS IS PROVIDED TO THE EXISTING BASEMENT
75 R311.1 MEANS OF EGRESS
FIGURE; THE REQUIRED EGRESS DOOR MUST HAVE ACCESS TO A PUBLIC WAY
FIGURE: DWELLING WITH FRONT-YARD ACCESS TO A PUBLIC WAY
76 R311.7.3, R311.7.5.1 STAIR RISERS
R311.7.3 VERTICAL RISE
R311.7.5.1 RISERS
FIGURE: OPEN RISERS ARE ONLY PERMITTED WHEN THEY ARE 30 INCHES OR LESS ABOVE THE FLOOR
78 R311.7.10.1 SPIRAL STAIRWAY
FIGURE: SPIRAL STAIRWAY
SECTION R202 DEFINITIONS
79 FIGURE: MEASURING THE TREAD OF SPIRAL STAIRS AT THE INTERSECTION OF THE TREAD NOSING AND THE WALKLINE
FIGURE: MAXIMUM WALKLINE RADIUS FOR A SPIRAL STAIRWAY
80 R311.7.11, R311.7.12 ALTERNATING TREAD DEVICES AND SHIP LADDERS
SECTION R202 DEFINITIONS
R311.7.11 ALTERNATING TREAD DEVICES
FIGURE: ALTERNATING TREAD DEVICE
81 FIGURE: SHIP LADDER
R311.7.11.1 TREAD OF ALTERNATING TREAD DEVICES
R311.7.11.2 HANDRAILS OF ALTERNATING TREAD DEVICES
R311.7.12 SHIP LADDERS
R311.7.12.1 TREADS OF SHIP LADDERS
R311.7.12.2 HANDRAILS OF SHIP LADDERS
83 R311.8 RAMPS
R311.8.1 MAXIMUM SLOPE
FIGURE: MAXIMUM RAMP SLOPES
FIGURE: RAMP SERVING THE REQUIRED EGRESS DOOR
85 R312.1.2 GUARD HEIGHT
R312.1.2 HEIGHT
FIGURE: EXAMPLE OF A GUARD WITH FIXED SEATING
FIGURE: MEASURING GUARD HEIGHT AT FIXED SEATING
87 R312.2.1 WINDOW FALL PROTECTION
R312.2.1 WINDOW SILLS
FIGURE: THREE METHODS FOR COMPLYING WITH THE WINDOW FALL PREVENTION PROVISIONS
88 R312.2.2 WINDOW OPENING CONTROL DEVICES
89 R314 SMOKE ALARMS
R314.1 GENERAL
FIGURE: SMOKE ALARM
R314.1.1 LISTINGS
R314.2 WHERE REQUIRED
R314.2.1 NEW CONSTRUCTION
R314.2.2 ALTERATIONS, REPAIRS, AND ADDITIONS
90 R314.3 LOCATION
R314.3.1 INSTALLATION NEAR COOKING APPLIANCES
FIGURE: SMOKE ALARM DISTANCES FROM BATHROOMS AND COOKING APPLIANCES
91 R314.4 INTERCONNECTION
R314.5 COMBINATION ALARMS
R314.6 POWER SOURCE
R314.7 FIRE ALARM SYSTEMS
R314.7.1 GENERAL
92 R314.7.2 LOCATION
R314.7.3 PERMANENT FIXTURE
R314.7.4 COMBINATION DETECTORS
95 R315 CARBON MONOXIDE ALARMS
R315.1 GENERAL
FIGURE: CARBON MONOXIDE ALARM
R315.1.1 LISTINGS
R315.2 WHERE REQUIRED
R315.2.1 NEW CONSTRUCTION
FIGURE: CARBON MONOXIDE ALARMS REQUIRED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN BEDROOMS CONTAINING FUEL-FIRED APPLIANCES
96 R315.2.2 ALTERATIONS, REPAIRS, AND ADDITIONS
R315.3 LOCATION
FIGURE: EXTERIOR WORK, SUCH AS A DECK ADDITION OR RE-SIDING, DOES NOT TRIGGER THE CARBON MONOXIDE PROVISIONS
97 R315.4 COMBINATION ALARMS
R315.5 POWER SOURCE
R315.6 CARBON MONOXIDE DETECTION SYSTEMS
R315.6.1 GENERAL
R315.6.2 LOCATION
R315.6.3 PERMANENT FIXTURE
R315.6.4 COMBINATION DETECTORS
100 R322.1, R322.2 FLOOD HAZARDS
R322.1 GENERAL
R322.1.1 ALTERNATIVE PROVISIONS
R322.2 FLOOD HAZARD AREAS
FIGURE: RESIDENTIAL CONSTRUCTION IN A COASTAL A ZONE
101 R322.2.1 ELEVATION REQUIREMENTS
103 R322.3 COASTAL HIGH-HAZARD AREAS
R322.3.3 FOUNDATIONS
FIGURE: PIER AND BEAM CONSTRUCTION IN A COASTAL HIGH-HAZARD AREA
106 R325 MEZZANINES
SECTION R202 DEFINITIONS
FIGURE: A MEZZANINE IS NOT CONSIDERED A STORY BUT MUST NOT EXCEED ONE-THIRD OF THE FLOOR AREA OF THE ROOM WHERE IT IS LOCATED
R301.2.2.3.1 HEIGHT LIMITATIONS
SECTION R325 MEZZANINES
R325.1 GENERAL
R325.2 MEZZANINES
R325.3 AREA LIMITATION
R325.4 MEANS OF EGRESS
R325.5 OPENNESS
108 PART 3 BUILDING CONSTRUCTION CHAPTERS 4 THROUGH 10
110 R403.1.1 MINIMUM FOOTING SIZE
TABLE R403.1(1) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS
112 FIGURE: FOOTING-STERN WALL
FIGURE: FOOTING-BASEMENT WALL
113 FIGURE: MINIMUM FOOTING SIZE EXAMPLES
115 R403.1.2, R602.10.9.1 CONTINUOUS FOOTINGS IN SEISMIC DESIGN CATEGORIES
FIGURE: CONTINUOUS FOOTING
116 R602.10.9.1 BRACED WALL PANEL SUPPORT FOR SEISMIC DESIGN CATEGORIES
117 TABLE 4-1 CONTINUOUS FOOTING REQUIREMENTS IN HIGH-SEISMIC REGIONS
118 R403.1.3 FOOTING AND STEM WALL REINFORCING IN SEISMIC DESIGN CATEGORIES
R403.1.3 FOOTING AND STEM WALL REINFORCING IN SEISMIC DESIGN CATEGORIES
R403.1.3.1 CONCRETE STEM WALLS WITH CONCRETE FOOTINGS
R403.1.3.2 MASONRY STEM WALLS WITH CONCRETE FOOTINGS
119 R403.1.3.3 SLABS-ON-GROUND WITH TURNED-DOWN FOOTINGS
R403.1.3.4 INTERIOR BEARING AND BRACED WALL PANEL FOOTINGS IN SEISMIC DESIGN CATEGORIES
R403.1.3.5 REINFORCEMENT
R403.1.3.5.1 STEEL REINFORCEMENT
R403.1.3.5.2 LOCATION OF REINFORCEMENT IN WALL
R403.1.3.5.3 SUPPORT AND COVER
120 FIGURE R403.1.3 REINFORCED CONCRETE FOOTINGS AND MASONRY AND CONCRETE STEMWALLS IN SDC
121 R403.1.3.5.4 LAP SPLICES
R403.1.3.6 ISOLATED CONCRETE FOOTINGS
122 R403.1.6 FOUNDATION ANCHORAGE
FIGURE: ANCHOR BOLT PLACEMENT-CENTERED IN SILL PLATE
FIGURE: ALTERNATE ANCHORAGE
123 FIGURE: MINIMUM EDGE DISTANCE
125 R404.1.4.1 MASONRY FOUNDATION WALLS IN SDC
R404.1.4.1 MASONRY FOUNDATION WALLS
FIGURE: MASONRY FOUNDATION WALL
126 R404.4 RETAINING WALLS
FIGURE: RETAINING WALL
127 TABLES R502.3.1(1), R502.3.1(2) FLOOR JOISTS SPANS FOR COMMON LUMBER SPECIES
TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (RESIDENTIAL SLEEPING AREAS, LIVE LOAD = 30 psf, L/Δ = 360)a
128 FIGURE: LUMBER FLOOR JOISTS
FIGURE: FLOOR JOIST SPAN EXAMPLES
130 R502.10 FRAMING OF FLOOR OPENINGS
FIGURE: OPENING IN FLOOR FRAMING
132 R507.1, R507.4 DECKING
R507.1 DECKS
R507.4 DECKING
TABLE R507.4 MAXIMUM JOIST SPACING
FIGURE: DECKING
134 R507.2 DECK LEDGER CONNECTION TO BAND JOIST
R507.2.1 LEDGER DETAILS
FIGURE: DECK LEDGER CONNECTION TO BAND JOIST
135 R507.2.2 BAND JOIST DETAILS
R507.2.3 LEDGER TO BAND JOIST FASTENER DETAILS
TABLE R507.2 DECK LEDGER CONNECTION TO BAND JOIST
137 R507.2.4 ALTERNATIVE DECK LATERAL LOAD CONNECTION
R507.2.4 DECK LATERAL LOAD CONNECTION
FIGURE: ALTERNATIVE DECK ATTACHMENT FOR LATERAL LOADS
139 R507.5, R507.6, R507.7 DECK JOISTS AND BEAMS
R507.5 DECK JOISTS
R507.5.1 LATERAL RESTRAINT AT SUPPORTS
FIGURE: TYPICAL DECK JOIST SPANS
140 TABLE R507.5 DECK JOIST SPANS FOR COMMON LUMBER SPECIES
FIGURE: TYPICAL DECK BEAM SPANS
141 R507.6 DECK BEAMS
R507.7 DECK JOIST AND DECK BEAM BEARING
TABLE R507.6 DECK BEAM SPAN LENGTH
142 R507.7.1 DECK POST TO DECK BEAM
FIGURE: CONNECTION OF DECK POSTS TO DECK BEAM
144 R507.8 DECK POSTS
TABLE R507.8 DECK POST HEIGHT
R507.8.1 DECK POST TO DECK FOOTING
FIGURE: TYPICAL DECK POSTS TO DECK FOOTINGS
145 TABLE R602.3(1) FASTENING SCHEDULE-ROOF REQUIREMENTS
TABLE R602.3(1) FASTENING SCHEDULE
146 FIGURE: ROOF FRAMING
147 TABLE R602.3(1) FASTENING SCHEDULE-WALL REQUIREMENTS
TABLE R602.3(1) FASTENING SCHEDULE
149 FIGURE: WALL FRAMING
150 TABLE R602.3(1) FASTENING SCHEDULE-FLOOR REQUIREMENTS
TABLE R602.3(1) FASTENING SCHEDULE FOR STRUCTURAL MEMBERS
151 FIGURE: FLOOR FRAMING
152 R602.3.1 STUD SIZE, HEIGHT, AND SPACING
154 FIGURE: EXAMPLE-PRESCRIPTIVE TALL WALLS
156 R602.7 HEADERS
FIGURE: SOLID-SAWN LUMBER HEADER
R602.7.1 SINGLE MEMBER HEADERS
R602.7.2 RIM BOARD HEADERS
FIGURE: RIM BOARD HEADER CONSTRUCTION
157 TABLE R602.7(1) GIRDER SPANS AND HEADER SPANS FOR EXTERIOR BEARING WALLS
TABLE R602.7(3) GIRDER AND HEADER SPANS FOR OPEN PORCHES
158 R602.7.5 SUPPORTS FOR HEADERS
TABLE R602.7.5 MINIMUM NUMBER OF FULL HEIGHT STUDS AT EACH END OF HEADERS IN EXTERIOR WALLS
160 TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED
TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED
161 FIGURE: WALL BRACING TO RESIST WIND FORCES
162 TABLE R602.10.5 CONTRIBUTING LENGTH OF METHOD CS-PF BRACED WALL PANELS
TABLE R602.10.5 MINIMUM LENGTH OF BRACED WALL PANELS
FIGURE: COMPARISON OF NAILING OF CS-PF AND PFG
164 R602.10.6.2 METHOD PFH: PORTAL FRAME WITH HOLD DOWNS
R602.10.6.2 METHOD PFH: PORTAL FRAME WITH HOLD DOWNS
FIGURE: METHOD PFH: PORTAL FRAME WITH HOLD DOWNS
166 R602.10.11 CRIPPLE WALL BRACING
FIGURE: BRACED WALL PANEL SPACING ON CRIPPLE WALLS
168 R602.12 SIMPLIFIED WALL BRACING
TABLE R602.12.4 MINIMUM NUMBER OF BRACING UNITS ON EACH SIDE OF THE CIRCUMSCRIBED RECTANGLE
171 R603.9.5 STRUCTURAL SHEATHING OVER STEEL FRAMING FOR STONE AND MASONRY VENEER
R603.9.5 STRUCTURAL SHEATHING FOR STONE AND MASONRY VENEER
R603.9.5.1 SEISMIC DESIGN CATEGORY C
R603.9.5.2 SEISMIC DESIGN CATEGORIES
TABLE R603.9.5(1) REQUIRED LENGTH OF FULL HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 33-MIL COLD-FORMED STEEL FRAMING AND 6-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
174 R606 MASONRY WALLS
TABLE 6-1 SUMMARY OF CHANGES TO THE MASONRY WALL CONSTRUCTION PROVISIONS OF SECTION R606
178 R606.3.5 GROUTING REQUIREMENTS FOR MASONRY CONSTRUCTION
R606.3.5 GROUTING REQUIREMENTS
R606.3.5.1 GROUT PLACEMENT
FIGURE: GROUTED CELLS
179 R606.3.5.2 CLEANOUTS
R606.3.5.3 CONSTRUCTION
181 R610.7 DRILLING AND NOTCHING IN STRUCTURAL INSULATED PANELS
R610.7 DRILLING AND NOTCHING
FIGURE: HOLES MADE ONSITE IN STRUCTURAL INSULATED PANELS
182 R703.3 SIDING MATERIAL THICKNESS AND ATTACHMENT
R703.3 NOMINAL THICKNESS AND ATTACHMENTS
R703.3.1 WIND LIMITATIONS
TABLE R703.3.1 LIMITS FOR ATTACHMENT PER TABLE R703.3(1)
183 R703.3.2 FASTENERS
TABLE R703.3.2 OPTIONAL SIDING ATTACHMENT SCHEDULE FOR FASTENERS WHERE NO STUD PENETRATION NECESSARY
R703.3.3 MINIMUM FASTENER LENGTH AND PENETRATION
184 TABLE R703.3(1) SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS
185 TABLE R703.3(2) SCREW FASTENER SUBSTITUTION FOR SIDING ATTACHMENT TO COLD-FORMED STEEL LIGHT FRAME CONSTRUCTION
187 R703.5 WOOD, HARDBOARD, AND WOOD STRUCTURAL PANEL SIDING
R703.5 WOOD, HARDBOARD, AND WOOD STRUCTURAL PANEL SIDING
R703.5.1 VERTICAL WOOD SIDING
FIGURE: WOOD SIDING OPTIONS
188 R703.5.2 PANEL SIDING
R703.5.3 HORIZONTAL WOOD SIDING
189 R703.6 WOOD SHAKES AND SHINGLES ON EXTERIOR WALLS
R703.6 WOOD SHAKES AND SHINGLES
R703.6.1 APPLICATION
FIGURE: WOOD SHINGLES AS EXTERIOR SIDING
190 TABLE 703.6.1 MINIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLS
R703.6.2 WEATHER EXPOSURE
R703.6.3 ATTACHMENT
191 TABLE R703.6.3(1) SINGLE COURSE SIDEWALL FASTENERS
192 TABLE R703.6.3(2) DOUBLE COURSE SIDEWALL FASTENERS
193 R703.9 EXTERIOR INSULATION AND FINISH SYSTEMS
R703.9 EXTERIOR INSULATION AND FINISH SYSTEM
R703.9.1 EXTERIOR INSULATION AND FINISH SYSTEMS
R703.9.2 EXTERIOR INSULATION AND FINISH SYSTEM WITH DRAINAGE
FIGURE: EIFS COMPOSITION
195 R703.11.1 VINYL SIDING ATTACHMENT
R703.11.1 INSTALLATION
R703.11.1.2 PENETRATION DEPTH
FIGURE: VINYL SIDING ATTACHMENT
196 FIGURE: VINYL SIDING INSTALLATION
R703.11.1.3 SPACING
R703.11.1.4 VINYL SOFFIT PANELS
SECTION R202 DEFINITIONS
198 R703.13,R703.14 INSULATED VINYL SIDING AND POLYPROPYLENE SIDING
703.13 INSULATED VINYL SIDING
703.13.1 INSULATED VINYL SIDING AND ACCESSORIES
R703.14 POLYPROPYLENE SIDING
R703.14.1 POLYPROPYLENE SIDING AND ACCESSORIES
R703.14.1.1 INSTALLATION
R703.14.1.2 FASTENER REQUIREMENTS
R703.14.2 FIRE SEPARATION
SECTION R202 DEFINITIONS
199 FIGURE: MINIMUM FIRE SEPARATION DISTANCE FOR POLYPROPYLENE SIDING
201 R703.15, R703.16, R703.17 CLADDING ATTACHMENT OVER FOAM SHEATHING
R703.15 CLADDING ATTACHMENT OVER FOAM SHEATHING TO WOOD FRAMING
FIGURE: SIDING ATTACHMENT OVER FOAM SHEATHING TO WOOD FRAMING
202 R703.15.1 DIRECT ATTACHMENT
TABLE R703.15.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
R703.15.2 FURRED CLADDING ATTACHMENT
R703.17 CLADDING ATTACHMENT OVER FOAM SHEATHING TO MASONRY OR CONCRETE WALL CONSTRUCTION
203 TABLE R703.15.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
205 TABLES R802.4, R802.5 CEILING JOIST AND RAFTER TABLES
TABLE R802.4(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
207 R806.1 ATTIC VENTILATION
R806.1 VENTILATION REQUIRED
FIGURE: ATTIC VENTILATION
208 TABLE R806.5 INSULATION FOR CONDENSATION CONTROL IN UNVENTED ATTICS
TABLE R806.5 INSULATION FOR CONDENSATION CONTROL
209 R905.1.1 UNDERLAYMENT
R905.1.1 UNDERLAYMENT
FIGURE: UNDERLAYMENT
210 R905.1.2 ICE BARRIERS
TABLE R905.1.1(1) UNDERLAYMENT TYPES
211 TABLE R905.1.1(2)
212 TABLE R905.1.1(3)
213 R905.7.5 WOOD SHINGLE APPLICATION
R905.7.5 APPLICATION
TABLE R905.7.5(2) NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES
215 R905.8.6 WOOD SHAKE APPLICATION
R905.8.6 APPLICATION
FIGURE: WOOD SHAKE ROOFING
217 R905.16 PHOTOVOLTAIC SHINGLES
R905.16 PHOTOVOLTAIC SHINGLES
R905.16.1 DECK REQUIREMENTS
R905.16.2 DECK SLOPE
R905.16.3 UNDERLAYMENT
R905.16.4 UNDERLAYMENT APPLICATION
R905.16.4.1 ICE BARRIER
FIGURE: PHOTO VOLTAIC SHINGLE
218 R905.16.4.2 UNDERLAYMENT AND HIGH WINDS
219 R907 ROOFTOP-MOUNTED PHOTOVOLTAIC SYSTEMS
R907.1 ROOFTOP-MOUNTED PHOTOVOLTAIC SYSTEMS
R907.2 WIND RESISTANCE
R907.3 FIRE CLASSIFICATION
R907.4 INSTALLATION
R907.5 PHOTOVOLTAIC PANELS AND MODULES
FIGURE: ROOFTOP-MOUNTED PHOTOVOLTAIC SYSTEM
220 PART 4 ENERGY CONSERVATION CHAPTER 11
221 N1101.13 COMPLIANCE PATHS
N1101.13 COMPLIANCE
FIGURE: BLOWER DOOR TEST
222 N1101.14 PERMANENT ENERGY CERTIFICATE
N1101.14 CERTIFICATE
FIGURE: A PERMANENT ENERGY CERTIFICATE MUST BE POSTED INSIDE THE BUILDING
223 FIGURE: PERMANENT ENERGY CERTIFICATE
224 N1102.1.3 R-VALUE COMPUTATION INSULATED SIDING
N1102.1.3 R-VALUE COMPUTATION
N1101.6 DEFINED TERMS
FIGURE: INSULATED SIDING
225 SECTION R202 DEFINITIONS
226 N1102.2.4 ACCESS HATCHES AND DOORS
N1102.2.4 (R402.2.4) ACCESS HATCHES AND DOORS
FIGURE: HORIZONTAL ATTIC ACCESS HATCH
FIGURE: VERTICAL ATTIC ACCESS DOOR
228 N1102.2.7, TABLE N1102.1.2 R-VALUE REDUCTION FOR WALLS WITH PARTIAL STRUCTURAL SHEATHING
N1102.2.7 (R402.2.7) WALLS WITH PARTIAL STRUCTURAL SHEATHING
FIGURE: R-VALUE REDUCTION FOR WALLS WITH PARTIAL STRUCTURAL SHEATHING
229 TABLE N11025.1.2 (R402.1.2)
230 N1102.2.8, TABLE N1102.4.1.1 FLOOR FRAMING CAVITY INSULATION
N1102.2.8 FLOORS
FIGURE: TWO OPTIONS FOR FLOOR INSULATION ABOVE UNCONDITIONED SPACE
FIGURE: OPTION FOR FLOOR INSULATION ABOVE RIGID INSULATION
231 TABLE N1102.4.1.1 AIR BARRIER AND INSULATION INSTALLATION
232 TABLE N1102.4.1.1 INSULATION AT WALL CORNERS AND HEADERS
TABLE N1102.4.1.1 (402.4.1.1) AIR BARRIER AND INSULATION INSTALLATION
FIGURE: INSULATION REQUIRED TO FILL SPACE AT HEADERS AND EXTERIOR WALL CORNERS
234 N1102.4.2, TABLE N1102.4.1.1 WOOD-BURNING FIREPLACE DOORS
N1102.4.2 (r402.4.2) FIREPLACES
TABLE N1102.4.1.1 (R402.4.1.1) AIR BARRIER AND INSULATION INSTALLATION
FIGURE: FIREPLACE DOORS MUST BE LISTED FOR THE APPLICATION
236 N1103.3 DUCT SEALING AND TESTING
N1103.3 (R403.3) DUCTS
N1103.3.2 (R403.3.1) SEALING
FIGURE: DUCT SEAL-MASTIC
237 N1103.3.3 (R403.3.3) DUCT TESTING
N1103.3.4 (R403.3.4) DUCT LEAKAGE
238 N1103.3.5 (R403.3.5) BUILDING CAVITIES
239 N1103.5 HEATED WATER CIRCULATION AND TEMPERATURE MAINTENANCE SYSTEMS
N1103.5 (R403.5) SERVICE HOT WATER SYSTEMS
N1103.5.1 (R403.5.1) HEATED WATER CIRCULATION AND TEMPERATURE MAINTENANCE SYSTEMS
FIGURE: AUTOMATIC DEMAND HEATED WATER CIRCULATION SYSTEMS
240 N1103.5.1.1 (R403.5.1.1) CIRCULATION SYSTEMS
N1103.5.1.2 (R403.5.1.2) HEAT TRACE SYSTEMS
241 PART 5 MECHANICAL CHAPTERS 12 THROUGH 23
242 M1502.4.4, M1502.4.5 DRYER EXHAUST DUCT POWER VENTILATORS
M1502.4.4 DRYER EXHAUST DUCT POWER VENTILATORS
M1502.4.5 DUCT LENGTH
M1502.4.5.1 SPECIFIED LENGTH
M1502.4.5.2 MANUFACTURER’S INSTRUCTIONS
M1502.4.5.3 DRYER EXHAUST DUCT POWER VENTILATOR
FIGURE: DRYER EXHAUST DUCT POWER VENTILATOR
244 M1502.4.6 DRYER DUCT LENGTH IDENTIFICATION
M1502.4.6 LENGTH IDENTIFICATION
FIGURE: A PERMANENT LABEL OR TAG IS ONLY REQUIRED WHEN THE EQUIVALENT LENGTH OF THE DRYER EXHAUST DUCT EXCEEDS 35 FEET
246 M1503.4 MAKEUP AIR FOR RANGE HOODS
M1503.4 MAKEUP AIR REQUIRED
FIGURE: REQUIRED MAKEUP AIR FOR KITCHEN EXHAUST HOODS EXCEEDING 400 CFM
247 M1503.4.1 LOCATION
248 M1506.2 EXHAUST DUCT LENGTH
SECTION M1506 EXHAUST DUCTS AND EXHAUST OPENINGS
M1506.1 DUCTS CONSTRUCTION
M1506.2 DUCT LENGTH
M1506.3 EXHAUST OPENINGS
FIGURE: MAXIMUM LENGTH OF EXHAUST DUCT IS BASED ON FAN RATING AND TYPE AND DIAMETER OF DUCT
249 TABLE M1506.2 DUCT LENGTH
250 M1601.1.1.1, TABLE M1601.1.1, M1601.2 ABOVE-GROUND DUCT SYSTEMS
M1601.1.1 ABOVE-GROUND DUCT SYSTEMS
FIGURE: DUCTS NOT GREATER THAN 14 INCHES IN DIAMETER MAY BE CONSTRUCTED OF 30-GAGE GALVANIZED SHEET METAL
251 TABLE M1601.1.1 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITS
253 M1601.4 DUCT INSTALLATION
M1601.4 INSTALLATION
M1601.4.1 JOINTS, SEAMS AND CONNECTIONS
FIGURE: TAPES AND MASTICS USED TO SEAL SHEET METAL DUCTS MUST BE LISTED TO UL 181 B
254 M1601.4.2 DUCT LAP
M1601.4.4 SUPPORT
256 M1602 RETURN AIR
SECTION M1602 RETURN AIR
M1602.1 OUTDOOR AIR OPENINGS
M1602.2 RETURN AIR OPENINGS
FIGURE: PROHIBITED SOURCES OF RETURN AIR INCLUDE UNCONDITIONED ATTICS AND CRAWL SPACES
258 PART 6 FUEL GAS CHAPTER 24
259 G2404.11 CONDENSATE PUMPS
FIGURE: CONDENSATE PUMPS LOCATED IN ATTICS AND CRAWL SPACES MUST BE CONNECTED TO THE APPLIANCE SUCH THAT WEHN THE PUMP FALLS THE APPLIANCE SHUTS OFF
260 G2411.1.1 ELECTRICAL BONDING OF CORRUGATED STAINLESS STEEL TUBING
FIGURE: BONDING OF CORRUGATED STAINLESS STEEL TUBING GAS PIPING
261 G2411.1.1.1 POINT OF CONNECTION
G2411.1.1.2 SIZE AND MATERIAL OF JUMPER
G2411.1.1.3 BONDING JUMPER LENGTH
G2411.1.1.4 BONDING CONNECTIONS
G2411.1.1.5 CONNECTION DEVICES
262 G2413.2 MAXIMUM GAS DEMAND
263 FIGURE: GAS PIPING SIZE IS BASED ON THE ACTUAL MAXIMUM INPUT RATING OF THE APPLIANCES
264 G2414.6 PLASTIC PIPE, TUBING AND FITTINGS
FIGURE: APPROVED POLYETHYLENE GAS PIPING WITH MARKINGS IN ACCORDANCE WITH THE CODE AND ASTM D 2513
265 G2415.5 FITTINGS IN CONCEALED LOCATIONS
FIGURE: THREADED ELBOWS, TEES AND COUPLINGS FOR SCHEDULE 40 STEEL GAS PIPING ARE PREMITTED IN CONCEALED LOCATIONS
267 G2415.7 PROTECTION OF CONCEALED PIPING AGAINST PHYSICAL DAMAGE
G2415.7.1 PIPING THROUGH BORED HOLES OR NOTCHES
FIGURE: CONCEALED GAS PIPING WITH MINIMUM CLEARANCE OF 1 1/2 INCHES DOES NOT REQUIRE PROTECTION
268 G2415.7.2 PIPING INSTALLED IN OTHER LOCATIONS
G2415.7.3 SHIELD PLATES
269 G2421.2 MEDIUM-PRESSURE REGULATORS
G2421.2 MP REGULATORS
FIGURE: UNION REQUIRED FOR MEDIUM-PRESSURE REGULATOR CONNECTED TO RIGID PIPING
271 G2422.1 CONNECTING PORTABLE AND MOVABLE APPLIANCES
G2422.1 CONNECTING APPLIANCES
FIGURE: NATURAL GAS HOSE CONNECTOR FOR PORTABLE OUTDOOR GAS APPLIANCES
272 G2422.1.5 MOVABLE APPLIANCES
273 G2426.7.1 DOOR CLEARANCE TO VENT TERMINALS
G2426.7.1 DOOR SWING
FIGURE: VENT TERMINALS MUST BE LOCATED SO DOORS CANNOT SWING WITHIN 12 INCHES TO PROTECT AGAINST PHYSICAL DAMAGE
274 FIGURE: THIS DIRECT-VENT TERMINAL IS SUBJECT TO DAMAGE FROM THE SWINGING DOOR
275 G2427.4.1, G2427.6.8.3 PLASTIC PIPING FOR APPLIANCE VENTS
G2427.4.1 PLASTIC PIPING
G2427.6.8.3 CATEGORY II, III AND IV APPLIANCES
FIGURE: THE TYPE OF MATERIAL AND SIZING OF PLASTIC PIPE THAT IS SPECIFIED BY THE APPLIANCE MANUFACTURER AS A VENTING MATERIAL SHALL BE IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS
277 G2427.8 VENTING SYSTEM TERMINATION LOCATION
FIGURE: A MINIMUM 10-FOOT HORIZONTAL SEPARATION IS REQUIRED BETWEEN A VENT TERMINAL AND AN OPENING OF AN ADJACENT BUILDING
279 G2439.4,G2439.7 CLOTHES DRYER EXHAUST DUCTS
G2439.4 DRYER EXHAUST DUCT POWER VENTILATORS
G2439.7 DOMESTIC CLOTHES DRYER EXHAUST DUCTS
G2439.7.2 DUCT INSTALLATION
G2439.7.4.3 DRYER EXHAUST DUCT POWER VENTILATOR LENGTH
FIGURE: INSTALLATION OF A DRYER EXHAUST DUCT POWER VENTILATOR IN ACCORDANCE WITH THE MAUFACTURER’S INSTRUCTIONS TO INCRASE THE ALLOWABLE LENGTH OF DRYER EXHAUST DUCT
280 FIGURE: DRYER DUCT JOINTS MUST BE INSERTED IN THE DIRECTION OF FLOW AND FASTENERS CANNOT PENETRATE MORE THAN 1/8 INCH
G2439.7.5 LENGTH IDENTIFICATION
281 FIGURE: A LENGTH IDENTIFICATION TAG IS REQUIRED IF THE EQUIVALENT DUCT LENGTH EXCEEDS 35 FEET
283 G2447.2 PROHIBITED LOCATION OF COMMERCIAL COOKING APPLIANCES
G2447.2 PROHIBITED LOCATION
FIGURE: HOUSEHOLD COOKING APPLIANCES
284 PART 7 PLUMBING CHAPTERS 25 THROUGH 33
286 P2502.1, P2503.4 INSPECTION AND TESTS FOR BUILDING SEWERS
P2502.1 EXISTING BUILDING SEWERS AND BUILDING DRAINS
P2503.4 BUILDING SEWER TESTING
FIGURE: EXISTING BUILDING DRAINS AND BUILDING SEWERS REQUIRE INTERNAL EXAMINATION TO VERIFY SLOPE AND CONDITION WHEN THE ENTIRE ABOVE-GROUND SANITARY DRAINAGE SYSTEM IS REPLACED
288 P2503.5 DRAIN, WASTE, AND VENT SYSTEMS TESTING
P2503.5 DRAIN, WASTE AND VENT SYSTEMS TESTING
FIGURE: WATER TEST ON DWV SYSTEM
289 P2503.5.1 ROUGH PLUMBING
P2503.5.2 FINISHED PLUMBING
290 P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE
FIGURE: PHYSICAL PROTECTION OF CONCEALED PIPING
292 P2603.3 PROTECTION AGAINST CORROSION
FIGURE: COPPER AND COPPER ALLOY PIPE AND TUBING REQUIRE PROTECTION FROM CORROSION WHEN IN CONTACT WITH CONCRETE, MASONRY AND STEEL FRAMING
294 TABLE P2605.1 PIPING SUPPORT
TABLE P2065.1 PIPING SUPPORT
295 FIGURE: A GUIDE IS REQUIRED AT THE MIDPOINT BETWEEN SUPPORTS FOR VERTICAL PLASTIC PIPING 2 INCHES AND SMALLER
296 P2702.1, P2706.1 WASTE RECEPTORS
SECTION R202 DEFINITIONS
P2702.1 PLUMBING FIXTURES
P2706.1 GENERAL
FIGURE: TYPICAL LAUNDRY STANDPIPE IS AN EXAMPLE OF A WASTE RECEPTOR
297 P2706.1.1 HUB DRAINS
P2706.1.2 STANDPIPES
P2706.1.2.1 LAUNDRY TRAY CONNECTION TO STANDPIPE
299 P2717 DISHWASHING MACHINES
P2717.1 PROTECTION OF WATER SUPPLY
P2717.2 SINK AND DISHWASHER
FIGURE: DISHWASHER DRAIN
301 P2801 WATER HEATER DRAIN VALVES AND PANS
P2801.1 REQUIRED
P2801.2 DRAIN VALVES
P2801.6 REQUIRED PAN
P2801.6.1 PAN SIZE AND DRAIN
302 FIGURE: WATER HEATER DRAIN VALVE WITH THREADED OUTLET AND DRAIN PAN
FIGURE: WATER HEATER PAN INSTALLATION
304 P2804.6.1 WATER HEATER RELIEF VALVE DISHCHARGE PIPING
P2804.6.1 REQUIREMENTS FOR DISCHARGE PIPING
FIGURE: AIR GAP FOR TEMPERATURE AND PRESSURE RELIEF VALVE DISCHARGE PIPE
306 P2901, P2910 THROUGH P2913
FIGURE: NONPOTABLE WATER OUTLETS SUCH AS HOSE CONNECTIONS REQUIRE WARNING SIGNS WITH A PICTOGRAPH
307 SECTION R202 DEFINITIONS
P2901.1 POTABLE WATER REQUIRED
P2901.2 IDENTIFICATION OF NONPOTABLE WATER SYSTEMS
P2901.2.1 SIGNAGE REQUIRED
P2901.2.2 DISTRIBUTION PIPE LABELING AND MARKING
308 TABLE P2901.2.2.2 SIZE OF PIPE IDENTIFICATION
P2901.2.2.1 COLOR
P2901.2.2.2 LETTERING SIZE
P2901.2.2.3 IDENTIFICATION TAPE
SECTION P2910 NONPOTABLE WATER SYSTEMS
SECTION P2911 ON-SITE NONPOTABLE WATER REUSE SYSTEMS
P2911.6.1 GRAY WATER USED FOR FIXTURE FLUSHING
SECTION P2912 NONPOTABLE RAINWATER COLLECTIONAND DISTRIBUTION SYSTEMS
SECTION P2913 RECLAIMED WATER SYSTEMS
311 P2905 HEATED WATER DISTRIBUTION SYSTEMS
P2905.1 HEATED WATER CIRCULATION SYSTEMS AND HEAT TRACE SYSTEMS
P2905.2 DEMAND RECIRCULATION SYSTEMS
FIGURE: HEAT TRACE TEMPERATURE MAINTENANCE SYSTEMS MUST COMPLY WITH THE ENERGY EFFICIENCY PROVISIONS OF CHAPTER 11 OF THE IRC
313 P2906.2 LEAD CONTENT OF DRINKING WATER PIPE AND FITTINGS
P2906.2 LEAD CONTENT
P2906.2.1 LEAD CONTENT OF DRINKING WATER PIPE AND FITTINGS
FIGURE: PIPE FITTINGS USED TO SUPPLY WATER FOR DRINKING OR COOKING PURPOSES MUST COMPLY WITH NSF 372 AND HAVE NOT GREATER THAN 0.25 PERCENT LEAD CONTENT
FIGURE: LOW LEAD THIRD-PARTY CERTIFICATION
315 P3003.9 SOLVENT CEMENTING OF PVC JOINTS
P3003.9 PVC PLASTIC
FIGURE: PURPLE PRIMER IS NO LONGER REQUIRED FOR JOINTS OF NON-PRESSURE PVC DWV PIPING 4 INCHES OR LESS IN DIAMETER
P3003.9.1 MECHANICAL JOINTS
P3003.9.2 SOLVENT CEMENTING
317 P3005.2 CLEANOUTS REQUIRED
P3005.2.3 BUILDING DRAIN AND BUILDING SEWER JUNCTION
P3005.2.6 CLEANOUT PLUGS
P3005.2.10 CLEANOUT ACCESS
FIGURE: CLEANOUT ON A STACK
319 P3008.1 BACKWATER VALVES
P3008.1 SEWAGE BACKFLOW
FIGURE: THE EXCEPTION ALLOWS THIS BACKWATER VALVE ARRANGEMENT ONLY FOR EXISTING BUILDINGS
321 P3103.1, P3103.2 VENT TERMINALS
P3103.1 ROOF EXTENSION
P3103.2 FROST CLOSURE
FIGURE: VENT TERMINAL REQUIREMENTS TO PREVENT FROST CLOSURE IN COLD CLIMATES
323 P3201.2 TRAP SEAL PROTECTION AGAINST EVAPORATION
P3201.2.1 TRAP SEAL PROTECTION
P3201.2.1.1 POTABLE WATER-SUPPLIED TRAP SEAL PRIMER VALVE
P3201.2.1.2 RECLAIMED OR GRAY-WATER-SUPPLIED TRAP SEAL PRIMER VALVE
FIGURE: A BARRIER-TYPE TRAP SEAL PROTECTION DEVICE IS ONE OF FOUR METHODS OF PROTECTING THE FLOOR DRAIN TRAP SEAL FROM EVAPORATION
324 P3201.2.1.3 WASTE-WATER-SUPPLIED TRAP PRIMER DEVICE
P3201.2.1.4 BARRIER-TYPE TRAP SEAL PROTECTION DEVICE
325 PART 8 ELECTRICAL CHAPTERS 34 THROUGH 43
326 E3901.9 RECEPTACLE OUTLETS FOR GARAGES
E3901.9 BASEMENTS, GARAGES AND ACCESSORY BUILDINGS
FIGURE: A MINIMUM OF TWO RECEPTACLE OUTLETS ARE REQUIRED FOR A TWO-STALL GARAGE
327 E3902.8, E3902.9, E3902.10 GROUND-FAULT CIRCUIT INTERRUPTER PROTECTION
E3902.8 BATHTUB OR SHOWER STALL RECEPTACLES
E3902.9 LAUNDRY AREAS
FIGURE: GFCI PROTECTION REQUIRED FOR 125-VOLT 15 AND 20-AMP RECEPTACLE OUTLETS IN LAUNDRY AREAS AND NEAR SHOWERS OR BATHTUBS
E3902.10 KITCHEN DISHWASHER BRANCH CIRCUIT
328 E4203.4.3 LOCATION OF LOW-VOLTAGE LUMINAIRES ADJACENT TO SWIMMING POOLS
E4203.4.3 LOW-VOLTAGE LUMINAIRES
FIGURE: LISTED LOW-VOLTAGE LUMINAIRS MEETING ALL CONDITIONS ARE ALLOWED WITHIN 5 FEET OF SWIMMING POOLS
329 E4204.2 BONDING OF OUTDOOR HOT TUBS AND SPAS
E4204.2 BONDED PARTS
330 FIGURE: EQUIPOTENTIAL BONDING IS NOT REQUIRED FOR SELF-CONTAINED HOT TUBS THAT ARE INSTALLED ABOVE GROUND IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS AND THE CODE REQUIREMENTS
331 PART 9 APPENDICES APPENDIX A THROUGH S
332 APPENDIX R LIGHT STRAW-CLAY CONSTRUCTION
SECTION AR101 GENERAL
AR101.1 SCOPE
SECTION AR102 DEFINITIONS
AR102.1 GENERAL
FIGURE: LIGHT STRAW-CLAY WALL CONSTRUCTION
333 SECTION AR103 NONBEARING LIGHT STRAW-CLAY CONSTRUCTION
AR103.1 GENERAL
AR103.2 STRUCTURE
AR103.2.1 NUMBER OF STORIES
AR103.2.2 BRACING
AR103.2.3 WEIGHT OF LIGHT STRAW-CLAY
334 AR103.2.4 REINFORCEMENT OF LIGHT STRAW-CLAY
AR103.3 MATERIALS
AR103.3.1 STRAW
336 APPENDIX S STRAWBALE CONSTRUCTION
FIGURE: STRAW
SECTION AS101 GENERAL
AS101.1 SCOPE
FIGURE: STRAW BALES
337 SECTION AS102 DEFINITIONS
SECTION AS103 BALES
SECTION AS104 FINISHES
SECTION AS105 STRAWBALE WALLS-GENERAL
SECTION AS106 STRAWBALE WALLS-STRUCTURAL
SECTION AS107 FIRE RESISTANCE
SECTION AS108 THERMAL INSULATION
SECTION AS109 REFERENCED STANDARDS
340 INDEX
350 ICC- DEDICATED TO THE SUPPORT OF BUILDING SAFETY PROFESSIONALS
351 ICC MEMBERSHIP
352 ICC EVALUATION SERVICE
353 GET IMMEDIATE DOWNLOADS OF THE STANDARDS YOU NEED
ICC SignificantChangestotheIRC 2015
$30.20