IECC 12:2012 Edition
$25.19
International Energy Conservation Code
Published By | Publication Date | Number of Pages |
ICC | 2012 | 155 |
Introduced in 1998, the IECC addresses energy efficiency on several fronts including cost savings, reduced energy usage, conservation of natural resources and the impact of energy usage on the environment. Important changes in this sixth edition include:
- A comprehensive set of changes includes measures to improve the thermal envelope, HVAC systems and electrical systems of residential buildings up to three stories in height.
- Commercial enhancements include required energy savings for windows, doors and skylights; thermal envelope efficiency; and increased efficiencies for installed HVAC equipment.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2012 INTERNATIONAL ENERGY CONSERVATION CODE® |
2 | 2012 INTERNATIONAL ENERGY CONSERVATION CODE® IECC® TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE |
8 | EFFECTIVE USE OF THE INTERNATIONAL ENERGY CONSERVATION CODE |
10 | LEGISLATION |
12 | TABLE OF CONTENTS |
14 | IECC—COMMERCIAL PROVISIONS TABLE OF CONTENTS |
16 | CHAPTER 1 [CE] SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION C101 SCOPE AND GENERAL REQUIREMENTS |
17 | SECTION C102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS PART 2—ADMINISTRATION AND ENFORCEMENT SECTION C103 CONSTRUCTION DOCUMENTS |
18 | SECTION C104 INSPECTIONS SECTION C105 VALIDITY SECTION C106 REFERENCED STANDARDS SECTION C107 FEES SECTION C108 STOP WORK ORDER |
19 | SECTION C109 BOARD OF APPEALS |
20 | CHAPTER 2 [CE] DEFINITIONS SECTION C201 GENERAL SECTION C202 GENERAL DEFINITIONS |
24 | CHAPTER 3 [CE] GENERAL REQUIREMENTS SECTION C301 CLIMATE ZONES |
25 | FIGURE C301.1 CLIMATE ZONES |
26 | TABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
27 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
28 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
29 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
30 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
31 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
32 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
33 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
34 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
35 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
36 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
37 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
38 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY TABLE C301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS |
39 | TABLE C301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS SECTION C302 DESIGN CONDITIONS SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT TABLE C303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR TABLE C303.1.3(2) DEFAULT DOOR U-FACTORS |
40 | TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT |
42 | CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY SECTION C401 GENERAL SECTION C402 BUILDING ENVELOPE REQUIREMENTS |
43 | TABLE C402.2.1.1 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa |
44 | TABLE C402.1.2 OPAQUE THERMAL ENVELOPE ASSEMBLY REQUIREMENTSa |
45 | TABLE C402.2 OPAQUE THERMAL ENVELOPE REQUIREMENTSa |
46 | EQUATION 4-1 TABLE C402.3 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION |
47 | EQUATION 4-2 TABLE C402.3.3.1 SHGC ADJUSTMENT MULTIPLIERS |
49 | TABLE C402.4.3 MAXIMUM AIR INFILTRATION RATE FOR FENESTRATION ASSEMBLIES |
50 | SECTION C403 BUILDING MECHANICAL SYSTEMS EQUATION 4-3 EQUATION 4-4 |
51 | TABLE C403.2.3(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS |
52 | TABLE C403.2.3(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS |
53 | TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS |
54 | TABLE C403.2.3(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS |
55 | TABLE C403.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS |
56 | TABLE C403.2.3(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS |
57 | TABLE 403.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS |
58 | TABLE C403.2.3(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS TABLE C403.2.3(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED |
59 | TABLE C403.2.3(7) MINIMUM EFFICIENCY REQUIREMENTS: WATER CHILLING PACKAGESa |
60 | TABLE C403.2.3(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT TABLE C403.2.3(9) HEAT TRANSFER EQUIPMENT |
62 | TABLE C403.2.6 ENERGY RECOVERY REQUIREMENT |
63 | EQUATION 4-5 TABLE C403.2.8 MINIMUM PIPE INSULATION THICKNESS (thickness in inches)a |
64 | TABLE C403.2.10.1(1) FAN POWER LIMITATION TABLE C403.2.10.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT |
65 | TABLE C403.3.1(1) ECONOMIZER REQUIREMENTS TABLE C403.3.1(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS |
66 | TABLE C403.3.1.1.3(1) HIGH-LIMIT SHUTOFF CONTROL OPTIONS FOR AIR ECONOMIZERS TABLE C403.3.1.1.3(2) HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERS |
69 | TABLE C403.4.7 MAXIMUM HOT GAS BYPASS CAPACITY SECTION C404 SERVICE WATER HEATING (MANATORY) |
70 | TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT |
71 | SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY) |
74 | TABLE C405.5.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD |
75 | TABLE C405.5.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD |
76 | TABLE C405.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.6.2(1) EXTERIOR LIGHTING ZONES SECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS |
77 | TABLE C405.6.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS |
78 | TABLE C406.2(1) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, EFFICIENCY REQUIREMENTS TABLE C406.2(2) UNITARY AND APPLIED HEAT PUMPS, ELECTRICALLY OPERATED, EFFICIENCY REQUIREMENTS TABLE C406.2(3) PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINALHEAT PUMPS |
79 | TABLE C406.2(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, EFFICIENCY REQUIREMENTS TABLE C406.2(5) BOILER, EFFICIENCY REQUIREMENTS |
80 | TABLE C406.2(6) CHILLERS—EFFICIENCY REQUIREMENTS |
81 | TABLE C406.2(7) ABSORPTION CHILLERS—EFFICIENCY REQUIREMENTS TABLE C406.3 REDUCED INTERIOR LIGHTING POWER SECTION C407 TOTAL BUILDING PERFORMANCE |
83 | TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
84 | TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
85 | TABLE C407.5.1(2) HVAC SYSTEMS MAP |
86 | TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS |
87 | TABLE C407.5.1(4) NUMBER OF CHILLERS TABLE C407.5.1(5) WATER CHILLER TYPES SECTION C408 SYSTEM COMMISSIONING |
90 | CHAPTER 5 REFERENCED STANDARDS AAMA AHAM AHRI |
91 | AMCA ANSI ASHRAE ASTM |
92 | CSA CTI DASMA |
93 | DOE ICC IESNA ISO |
94 | NFRC SMACNA UL US-FTC WDMA |
96 | INDEX |
104 | IECC—RESIDENTIAL PROVISIONS TABLE OF CONTENTS |
106 | CHAPTER 1 [RE] SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION R101 SCOPE AND GENERAL REQUIREMENTS |
107 | SECTION R102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS PART 2—ADMINISTRATION AND ENFORCEMENT SECTION R103 CONSTRUCTION DOCUMENTS |
108 | SECTION R104 INSPECTIONS SECTION R105 VALIDITY SECTION R106 REFERENCED STANDARDS SECTION R107 FEES SECTION R108 STOP WORK ORDER |
109 | SECTION R109 BOARD OF APPEALS |
110 | CHAPTER 2 [RE] DEFINITIONS SECTION R201 GENERAL SECTION R202 GENERAL DEFINITIONS |
114 | CHAPTER 3 [RE] GENERAL REQUIREMENTS SECTION R301 CLIMATE ZONES |
115 | FIGURE R301.1 CLIMATE ZONES |
116 | TABLE R301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
117 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
118 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
119 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
120 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
121 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
122 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
123 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
124 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
125 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
126 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
127 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
128 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY TABLE R301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS |
129 | TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS SECTION R302 DESIGN CONDITIONS SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR TABLE R303.1.3(2) DEFAULT DOOR U-FACTORS |
130 | TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT |
132 | CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY SECTION R401 GENERAL SECTION R402 BUILDING THERMAL ENVELOPE TABLE R402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa |
133 | TABLE R402.1.3 EQUIVALENT U-FACTORSa |
134 | TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE) |
135 | TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATION |
136 | SECTION R403 SYSTEMS |
137 | TABLE R403.4.2 MAXIMUM RUN LENGTH (feet)a TABLE R403.5.1 MECHANICAL VENTILATION SYSTEM FAN EFFICACY |
138 | SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY) SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE) |
140 | TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
141 | TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
142 | TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa |
144 | CHAPTER 5 REFERENCED STANDARDS AAMA ACCA ASHRAE ASTM |
145 | CSA ICC NFRC US-FTC WDMA |
146 | INDEX |
152 | ICC MEMBERSHIP BENEFITS |
153 | ICC EVALUATION SERVICE ICC-ES |
154 | MAINTAIN YOUR SUSTAINABLE BUILDING EXPERTISE WITH GREEN/ENERGY TRAINING |
155 | COMMITTED TO BUILDING A GREEN AND SUSTAINABLE WORLD |