IPC Commentary 06 2006
$45.23
International Plumbing Code and Commentary
Published By | Publication Date | Number of Pages |
ICC | 2006 | 491 |
This comprehensive publication provides a convenient reference for regulations in the 2006 International Plumbing Code® (IPC®). The commentary series is presented in an easy-to-understand format. Every chapter begins with “General Comments” and “Purpose” sections followed by code and commentary to subsequent sections, tables and figures. This in-depth publication focuses on providing the full meaning and implications of the 2006 IPC®.
The commentaries are designed to suggest the most effective method of application, and the consequences of not adhering to the code. This is an excellent reference for code officials, engineers, architects, inspectors, plans examiners, contractors and anyone who needs a better understanding of the 2006 IPC
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | WELCOME PAGE WELCOME PAGE 2006 INTERNATIONAL PLUMBING CODE® CODE AND COMMENTARY 2006 INTERNATIONAL PLUMBING CODE® CODE AND COMMENTARY |
2 | TITLE PAGE TITLE PAGE |
3 | COPYRIGHT COPYRIGHT |
4 | PREFACE PREFACE |
6 | TABLE OF CONTENTS TABLE OF CONTENTS |
8 | CHAPTER 1: ADMINISTRATION CHAPTER 1: ADMINISTRATION GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION 101 GENERAL SECTION 101 GENERAL |
9 | SECTION 102 APPLICABILITY SECTION 102 APPLICABILITY |
11 | SECTION 103 DEPARTMENT OF PLUMBING INSPECTION SECTION 103 DEPARTMENT OF PLUMBING INSPECTION |
12 | SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL |
14 | SECTION 105 APPROVAL SECTION 105 APPROVAL |
16 | SECTION 106 PERMITS SECTION 106 PERMITS |
19 | SECTION 107 INSPECTIONS AND TESTING SECTION 107 INSPECTIONS AND TESTING |
22 | SECTION 108 VIOLATIONS SECTION 108 VIOLATIONS |
24 | SECTION 109 MEANS OF APPEAL SECTION 109 MEANS OF APPEAL |
25 | BIBLIOGRAPHY BIBLIOGRAPHY |
26 | CHAPTER 2: DEFINITIONS CHAPTER 2: DEFINITIONS GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION 201 GENERAL SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS SECTION 202 GENERAL DEFINITIONS |
28 | FIGURE 202(1) AIR ADMITTANCE VALVE OPENS TO ADMIT AIR TO RELIEVE NEGATIVE PRESSURE FIGURE 202(1) AIR ADMITTANCE VALVE OPENS TO ADMIT AIR TO RELIEVE NEGATIVE PRESSURE FIGURE 202(2) AIR ADMITTANCE VALVE CLOSES AND SEALS VENT UNDER NEUTRAL OR POSITIVE PRESSURES FIGURE 202(2) AIR ADMITTANCE VALVE CLOSES AND SEALS VENT UNDER NEUTRAL OR POSITIVE PRESSURES |
29 | FIGURE 202(3) MECHANICAL VENT FIGURE 202(3) MECHANICAL VENT FIGURE 202(4) AIR GAP, AIR BREAK FIGURE 202(4) AIR GAP, AIR BREAK |
32 | FIGURE 202(5) DEFINITION OF BRANCH INTERVAL FIGURE 202(5) DEFINITION OF BRANCH INTERVAL |
33 | FIGURE 202(6) DEFINITION OF BRANCH INTERVAL FIGURE 202(6) DEFINITION OF BRANCH INTERVAL |
34 | FIGURE 202(7) BRANCH VENT FIGURE 202(7) BRANCH VENT |
35 | FIGURE 202(8) DRAINAGE SYSTEM COMPONENTS FIGURE 202(8) DRAINAGE SYSTEM COMPONENTS |
37 | FIGURE 202(9) DEPTH OF WATER SEAL FIGURE 202(9) DEPTH OF WATER SEAL |
39 | FIGURE 202(10) FIXTURE AND HORIZONTAL BRANCH DRAIN FIGURE 202(10) FIXTURE AND HORIZONTAL BRANCH DRAIN |
40 | FIGURE 202(11) FIXTURE DRAIN FIGURE 202(11) FIXTURE DRAIN |
42 | FIGURE 202(12) SENSOR-CONTROLLED GREASE RECOVERY DEVICE FIGURE 202(12) SENSOR-CONTROLLED GREASE RECOVERY DEVICE FIGURE 202(13) TIMER CONTROLLED GREASE RECOVERY DEVICE FIGURE 202(13) TIMER CONTROLLED GREASE RECOVERY DEVICE |
43 | FIGURE 202(14) GREASE REMOVAL DEVICE, AUTOMATIC FIGURE 202(14) GREASE REMOVAL DEVICE, AUTOMATIC |
44 | FIGURE 202(15) THE THREE TYPES OF WATER DISTRIBUTION SYSTEMS FIGURE 202(15) THE THREE TYPES OF WATER DISTRIBUTION SYSTEMS |
47 | FIGURE 202(16) PARTS OF PLUMBING SYSTEM FIGURE 202(16) PARTS OF PLUMBING SYSTEM |
53 | BIBLIOGRAPHY BIBLIOGRAPHY |
56 | CHAPTER 3: GENERAL REGULATIONS CHAPTER 3: GENERAL REGULATIONS GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION 301 GENERAL SECTION 301 GENERAL |
57 | SECTION 302 EXCLUSION OF MATERIALS DETRIMENTALTO THE SEWER SYSTEM SECTION 302 EXCLUSION OF MATERIALS DETRIMENTALTO THE SEWER SYSTEM SECTION 303 MATERIALS SECTION 303 MATERIALS |
58 | TABLE 303.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION TABLE 303.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION SECTION 304 RODENTPROOFING SECTION 304 RODENTPROOFING |
59 | FIGURE 303.4 SAMPLE MARKING OF PVC PIPE FIGURE 303.4 SAMPLE MARKING OF PVC PIPE SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS |
60 | TABLE 305.3 PIPE EXPANSION TABLE 305.3 PIPE EXPANSION |
61 | FIGURE 305.3(1) “L” BEND FIGURE 305.3(1) “L” BEND FIGURE 305.3(2) “Z” BEND FIGURE 305.3(2) “Z” BEND FIGURE 305.3(3) “U” BEND FIGURE 305.3(3) “U” BEND |
62 | FIGURE 305.5 PIPE PROTECTION FIGURE 305.5 PIPE PROTECTION FIGURE 305.6(1) PROTECTION AGAINST FREEZING FIGURE 305.6(1) PROTECTION AGAINST FREEZING |
63 | FIGURE 305.6(2) TYPICAL FREEZEPROOF HOSE (SILL) FAUCET INSTALLATION NOT REQUIRING SEPARATE VALVE FIGURE 305.6(2) TYPICAL FREEZEPROOF HOSE (SILL) FAUCET INSTALLATION NOT REQUIRING SEPARATE VALVE |
64 | FIGURE 305.6(3) SEVERE FROST PENETRATION LEVELS FIGURE 305.6(3) SEVERE FROST PENETRATION LEVELS FIGURE 305.7 ROOF PENETRATIONS FIGURE 305.7 ROOF PENETRATIONS |
65 | FIGURE 305.8(1) PIPE PROTECTION FIGURE 305.8(1) PIPE PROTECTION |
66 | FIGURE 305.8(2) NONCOMPLIANT PIPE PROTECTION FIGURE 305.8(2) NONCOMPLIANT PIPE PROTECTION FIGURE 305.9 PROTECTION OF PLUMBING SYSTEM COMPONENTS FIGURE 305.9 PROTECTION OF PLUMBING SYSTEM COMPONENTS |
67 | SECTION 306 TRENCHING, EXCAVATION AND BACKFILL SECTION 306 TRENCHING, EXCAVATION AND BACKFILL FIGURE 306.2 PIPE ON BOTTOM OF TRENCH FIGURE 306.2 PIPE ON BOTTOM OF TRENCH FIGURE 306.2.1 OVEREXCAVATED TRENCH FIGURE 306.2.1 OVEREXCAVATED TRENCH |
68 | FIGURE 306.3 BACKFILLING 6-INCH TAMPED LAYER FIGURE 306.3 BACKFILLING 6-INCH TAMPED LAYER |
69 | SECTION 307 STRUCTURAL SAFETY SECTION 307 STRUCTURAL SAFETY FIGURE 307.2(1) NOTCHES OR HOLES IN WOOD STUDS FIGURE 307.2(1) NOTCHES OR HOLES IN WOOD STUDS |
70 | FIGURE 307.2(2) HOLES AND NOTCHES IN WOOD JOISTS FIGURE 307.2(2) HOLES AND NOTCHES IN WOOD JOISTS |
71 | FIGURE 307.2(3) NONCOMPLIANT NOTCH IN FLOOR JOIST FIGURE 307.2(3) NONCOMPLIANT NOTCH IN FLOOR JOIST FIGURE 307.2(4) NOTCHING AND BORING IN A WOOD STUD WALL FIGURE 307.2(4) NOTCHING AND BORING IN A WOOD STUD WALL |
72 | FIGURE 307.3(1) COMBUSTIBLE PIPE PENETRATION OF FIRE-RATED WALL FIGURE 307.3(1) COMBUSTIBLE PIPE PENETRATION OF FIRE-RATED WALL FIGURE 307.3(2) ANNULAR SPACE PROTECTION FIGURE 307.3(2) ANNULAR SPACE PROTECTION SECTION 308 PIPING SUPPORT SECTION 308 PIPING SUPPORT |
73 | FIGURE 307.3(3) PIPE PENETRATION OF FIRE-RESISTANCE-RATED ROOF/CEILING ASSEMBLY FIGURE 307.3(3) PIPE PENETRATION OF FIRE-RESISTANCE-RATED ROOF/CEILING ASSEMBLY FIGURE 307.3(4) PIPE PENETRATION OF FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY FIGURE 307.3(4) PIPE PENETRATION OF FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY |
74 | FIGURE 307.4 PROHIBITED ALTERATION (TOP CHORD OF FLOOR TRUSS REMOVED) FIGURE 307.4 PROHIBITED ALTERATION (TOP CHORD OF FLOOR TRUSS REMOVED) FIGURE 307.5 EXCAVATION IN RELATION TO FOOTING FIGURE 307.5 EXCAVATION IN RELATION TO FOOTING |
75 | TABLE 308.5 HANGER SPACING TABLE 308.5 HANGER SPACING FIGURE 308.5(1) POINT OF SAG BETWEEN HANGERS FIGURE 308.5(1) POINT OF SAG BETWEEN HANGERS |
76 | FIGURE 308.5(2) LOCATION OF HANGERS FIGURE 308.5(2) LOCATION OF HANGERS FIGURE 308.6S WAY BRACING FIGURE 308.6S WAY BRACING |
77 | FIGURE 308.7 RESTRAINED COUPLING FIGURE 308.7 RESTRAINED COUPLING FIGURE 308.7.1 ANCHORAGE LOCATION FIGURE 308.7.1 ANCHORAGE LOCATION SECTION 309 FLOOD HAZARD RESISTANCE SECTION 309 FLOOD HAZARD RESISTANCE |
78 | FIGURE 308.9(1) PIPE SUPPORT FIGURE 308.9(1) PIPE SUPPORT FIGURE 308.9(2) PIPE BEND SUPPORT MAINTAINING BEND RADIUS FIGURE 308.9(2) PIPE BEND SUPPORT MAINTAINING BEND RADIUS |
79 | SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS |
80 | FIGURE 310.2 FIXTURE AND PIPING OBSTRUCTIONS FIGURE 310.2 FIXTURE AND PIPING OBSTRUCTIONS |
81 | FIGURE 310.5(1) URINAL PARTITIONS FIGURE 310.5(1) URINAL PARTITIONS SECTION 311 TOILET FACILITIES FOR WORKERS SECTION 311 TOILET FACILITIES FOR WORKERS SECTION 312 TESTS AND INSPECTIONS SECTION 312 TESTS AND INSPECTIONS |
82 | FIGURE 310.5(2) URINAL PARTITIONS FIGURE 310.5(2) URINAL PARTITIONS TABLE 311.1 MINIMUM NUMBER OF TOILET FACILITIES TABLE 311.1 MINIMUM NUMBER OF TOILET FACILITIES |
85 | SECTION 313 EQUIPMENT EFFICIENCIES SECTION 313 EQUIPMENT EFFICIENCIES SECTION 314 CONDENSATE DISPOSAL SECTION 314 CONDENSATE DISPOSAL |
87 | FIGURE 314.2.3(1) CONDENSATE OVERFLOW SWITCH FIGURE 314.2.3(1) CONDENSATE OVERFLOW SWITCH FIGURE 314.2.3(2) CONDENSATE OVERFLOW SWITCH FIGURE 314.2.3(2) CONDENSATE OVERFLOW SWITCH FIGURE 314.2.3(3) PRIMARY OR AUXILIARY DRAIN PAN FLOAT SWITCH FIGURE 314.2.3(3) PRIMARY OR AUXILIARY DRAIN PAN FLOAT SWITCH |
88 | BIBLIOGRAPHY BIBLIOGRAPHY |
90 | CHAPTER 4: FIXTURES, FAUCETS AND FIXTURE FITTINGS CHAPTER 4: FIXTURES, FAUCETS AND FIXTURE FITTINGS GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION 401 GENERAL SECTION 401 GENERAL |
91 | SECTION 402 FIXTURE MATERIALS SECTION 402 FIXTURE MATERIALS SECTION 403 MINIMUM PLUMBING FACILITIES SECTION 403 MINIMUM PLUMBING FACILITIES |
92 | TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES a(See Sections 403.2 and 403.3) TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES a(See Sections 403.2 and 403.3) |
95 | EXAMPLE 1 TOTAL NUMBER OF REQUIRED FIXTURES(Mixed-Use Building) EXAMPLE 1 TOTAL NUMBER OF REQUIRED FIXTURES(Mixed-Use Building) |
96 | EXAMPLE 2 TOTAL NUMBER OF REQUIRED FIXTURES (Mixed-Use Building) EXAMPLE 2 TOTAL NUMBER OF REQUIRED FIXTURES (Mixed-Use Building) |
97 | EXAMPLE 3 TOTAL NUMBER OF REQUIRED FIXTURES EXAMPLE 3 TOTAL NUMBER OF REQUIRED FIXTURES EXAMPLE 3 TOTAL NUMBER OF REQUIRED FIXTURES EXAMPLE 3 TOTAL NUMBER OF REQUIRED FIXTURES |
99 | FIGURE 403.4 CUSTOMER TOILET ACCESS FIGURE 403.4 CUSTOMER TOILET ACCESS SECTION 404 ACCESSIBLE PLUMBING FACILITIES SECTION 404 ACCESSIBLE PLUMBING FACILITIES |
100 | SECTION 405 INSTALLATION OF FIXTURES SECTION 405 INSTALLATION OF FIXTURES FIGURE 405.3.1 FIXTURE CLEARANCES FIGURE 405.3.1 FIXTURE CLEARANCES |
101 | FIGURE 405.4 WATER CLOSET FLOOR FLANGE FIGURE 405.4 WATER CLOSET FLOOR FLANGE |
102 | FIGURE 405.4.3 WALL-HUNG WATER CLOSET FIGURE 405.4.3 WALL-HUNG WATER CLOSET FIGURE 405.5 JOINTS BETWEEN FIXTURES AND WALLS OR FLOORS FIGURE 405.5 JOINTS BETWEEN FIXTURES AND WALLS OR FLOORS |
103 | FIGURE 405.7 FIXTURE OVERFLOW FIGURE 405.7 FIXTURE OVERFLOW SECTION 406 AUTOMATIC CLOTHES WASHERS SECTION 406 AUTOMATIC CLOTHES WASHERS |
104 | FIGURE 406.3 CLOTHES WASHER TRENCH DRAIN FIGURE 406.3 CLOTHES WASHER TRENCH DRAIN SECTION 407 BATHTUBS SECTION 407 BATHTUBS |
105 | SECTION 408 BIDETS SECTION 408 BIDETS |
106 | SECTION 409 DISHWASHING MACHINES SECTION 409 DISHWASHING MACHINES SECTION 410 DRINKING FOUNTAINS SECTION 410 DRINKING FOUNTAINS |
107 | SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS SECTION 412 FLOOR AND TRENCH DRAINS SECTION 412 FLOOR AND TRENCH DRAINS |
108 | FIGURE 412.2(1) TYPICAL FLOOR DRAIN WITHOUT INTEGRAL TRAP FIGURE 412.2(1) TYPICAL FLOOR DRAIN WITHOUT INTEGRAL TRAP FIGURE 412.2(2) TYPICAL FLOOR DRAIN WITH INTEGRAL TRAP FIGURE 412.2(2) TYPICAL FLOOR DRAIN WITH INTEGRAL TRAP SECTION 413 FOOD WASTE GRINDER UNITS SECTION 413 FOOD WASTE GRINDER UNITS |
109 | FIGURE 413.3 COMMERCIAL FOOD WASTE GRINDER FIGURE 413.3 COMMERCIAL FOOD WASTE GRINDER SECTION 414 GARBAGE CAN WASHERS SECTION 414 GARBAGE CAN WASHERS |
110 | FIGURE 414.2 GARBAGE CAN WASHER FIGURE 414.2 GARBAGE CAN WASHER SECTION 415 LAUNDRY TRAYS SECTION 415 LAUNDRY TRAYS SECTION 416 LAVATORIES SECTION 416 LAVATORIES |
111 | FIGURE 416.1 GROUP WASH-UP FIXTURE FIGURE 416.1 GROUP WASH-UP FIXTURE SECTION 417 SHOWERS SECTION 417 SHOWERS |
112 | FIGURE 417.2 SECURING SHOWER RISER FIGURE 417.2 SECURING SHOWER RISER |
113 | FIGURE 417.3 SHOWER FLOOR DESIGN FIGURE 417.3 SHOWER FLOOR DESIGN |
114 | FIGURE 417.4 SHOWER COMPARTMENT FIGURE 417.4 SHOWER COMPARTMENT |
115 | FIGURE 417.5.2 SHOWER LINING CONNECTION FIGURE 417.5.2 SHOWER LINING CONNECTION SECTION 418 SINKS SECTION 418 SINKS |
116 | SECTION 419 URINALS SECTION 419 URINALS |
117 | FIGURE 419.1(1) WATERLESS URINAL FIGURE 419.1(1) WATERLESS URINAL FIGURE 419.1(2) WATERLESS URINAL CARTRIDGE FIGURE 419.1(2) WATERLESS URINAL CARTRIDGE SECTION 420 WATER CLOSETS SECTION 420 WATER CLOSETS |
118 | FIGURE 419.3 URINAL SURROUNDING MATERIAL FIGURE 419.3 URINAL SURROUNDING MATERIAL |
119 | FIGURE 420.1(1) BOWL DESIGN FIGURE 420.1(1) BOWL DESIGN FIGURE 420.1(2) FLUSHING ACTION FOR CERTAIN WATER CLOSETS FIGURE 420.1(2) FLUSHING ACTION FOR CERTAIN WATER CLOSETS |
120 | FIGURE 420.1 WATER CLOSET BOWL HEIGHTS FIGURE 420.1 WATER CLOSET BOWL HEIGHTS FIGURE 420.1(3) DETERMINING WATER CLOSET RIM HEIGHT FIGURE 420.1(3) DETERMINING WATER CLOSET RIM HEIGHT FIGURE 420.4 ACCEPTABLE 4 X 3 CLOSET BENDS FIGURE 420.4 ACCEPTABLE 4 X 3 CLOSET BENDS SECTION 421 WHIRLPOOL BATHTUBS SECTION 421 WHIRLPOOL BATHTUBS |
121 | FIGURE 421.5(1) NONCOMPLIANT WHIRLPOOL BATHTUB PUMP ACCESS FIGURE 421.5(1) NONCOMPLIANT WHIRLPOOL BATHTUB PUMP ACCESS SECTION 422 HEALTH CARE FIXTURES AND EQUIPMENT SECTION 422 HEALTH CARE FIXTURES AND EQUIPMENT |
122 | FIGURE 421.5(2) NONCOMPLIANT WHIRLPOOL BATHTUB PUMP ACCESS FIGURE 421.5(2) NONCOMPLIANT WHIRLPOOL BATHTUB PUMP ACCESS |
123 | SECTION 423 SPECIALTY PLUMBING FIXTURES SECTION 423 SPECIALTY PLUMBING FIXTURES |
124 | SECTION 424 FAUCETS AND OTHER FIXTURE FITTINGS SECTION 424 FAUCETS AND OTHER FIXTURE FITTINGS |
125 | TABLE 424.3 TEMPERATURE BURN CHART TABLE 424.3 TEMPERATURE BURN CHART |
126 | FIGURE 424.4 STANDARDS RELATED TO FIXTURE APPLICATIONS FIGURE 424.4 STANDARDS RELATED TO FIXTURE APPLICATIONS |
127 | TABLE 424.4 MAXIMUM TEMPERATURES ALLOWED AT USE LOCATIONS TABLE 424.4 MAXIMUM TEMPERATURES ALLOWED AT USE LOCATIONS SECTION 425 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS SECTION 425 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS |
129 | SECTION 426 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT SECTION 426 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT SECTION 427 FLOOR SINKS SECTION 427 FLOOR SINKS BIBLIOGRAPHY BIBLIOGRAPHY |
132 | CHAPTER 5: WATER HEATERS CHAPTER 5: WATER HEATERS GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION 501 GENERAL SECTION 501 GENERAL |
133 | FIGURE 501.2 WATER-TO-AIR HEAT EXCHANGER FIGURE 501.2 WATER-TO-AIR HEAT EXCHANGER |
135 | TABLE 501.6(1) TYPICAL CAPACITY TABLE FOR TANKLESS WATER HEATERS TABLE 501.6(1) TYPICAL CAPACITY TABLE FOR TANKLESS WATER HEATERS FIGURE 501.6(1) TYPICAL CAPACITY GRAPH FOR TANKLESS WATER HEATERS FIGURE 501.6(1) TYPICAL CAPACITY GRAPH FOR TANKLESS WATER HEATERS |
136 | FIGURE 501.6(2) TYPICAL DETERMINATION OF FLOW AT GIVEN TEMPERATURE RISE FIGURE 501.6(2) TYPICAL DETERMINATION OF FLOW AT GIVEN TEMPERATURE RISE |
137 | SECTION 502 INSTALLATION SECTION 502 INSTALLATION |
138 | SECTION 503 CONNECTIONS SECTION 503 CONNECTIONS |
139 | FIGURE 503.1 WATER HEATER VALVE FIGURE 503.1 WATER HEATER VALVE SECTION 504 SAFETY DEVICES SECTION 504 SAFETY DEVICES |
140 | FIGURE 504.2 WATER HEATER WITH BOTTOM FEED FIGURE 504.2 WATER HEATER WITH BOTTOM FEED FIGURE 504.4 COMBINATION TEMPERATURE AND PRESSURE-RELIEF VALVE FIGURE 504.4 COMBINATION TEMPERATURE AND PRESSURE-RELIEF VALVE |
141 | FIGURE 504.4.1 TEMPERATURE- AND PRESSURE-RELIEF VALVE INSTALLATION FIGURE 504.4.1 TEMPERATURE- AND PRESSURE-RELIEF VALVE INSTALLATION |
142 | FIGURE 504.5 COMBINATION TEMPERATURE- AND PRESSURE-RELIEF VALVE LABEL FIGURE 504.5 COMBINATION TEMPERATURE- AND PRESSURE-RELIEF VALVE LABEL |
143 | FIGURE 504.6(1) RELIEF VALVE DISCHARGE FIGURE 504.6(1) RELIEF VALVE DISCHARGE |
144 | FIGURE 504.6(2) RELIEF VALVE INDIRECT WASTE FIGURE 504.6(2) RELIEF VALVE INDIRECT WASTE |
145 | FIGURE 504.7 WATER HEATER IN PAN FIGURE 504.7 WATER HEATER IN PAN SECTION 505 INSULATION SECTION 505 INSULATION BIBLIOGRAPHY BIBLIOGRAPHY |
148 | CHAPTER 6: WATER SUPPLY AND DISTRIBUTION CHAPTER 6: WATER SUPPLY AND DISTRIBUTION GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION 601 GENERAL SECTION 601 GENERAL |
149 | SECTION 602 WATER REQUIRED SECTION 602 WATER REQUIRED |
150 | SECTION 603 WATER SERVICE SECTION 603 WATER SERVICE |
151 | FIGURE 603.1(1) RESIDENTIAL WATER SERVICE SCHEMATIC FIGURE 603.1(1) RESIDENTIAL WATER SERVICE SCHEMATIC |
152 | TABLE 603.1 TABLE FOR ESTIMATING DEMAND TABLE 603.1 TABLE FOR ESTIMATING DEMAND |
153 | FIGURE 603.1(2) FRICTION LOSS IN SMOOTH PIPE a (Type L, ASTM B 88 Copper Tubing) FIGURE 603.1(2) FRICTION LOSS IN SMOOTH PIPE a (Type L, ASTM B 88 Copper Tubing) |
154 | FIGURE 603.1(3) FRICTION LOSS IN SDR 9 PEX TUBING FIGURE 603.1(3) FRICTION LOSS IN SDR 9 PEX TUBING |
155 | FIGURE 603.2(1) SEPARATION OF WATER SERVICE AND BUILDING SEWER FIGURE 603.2(1) SEPARATION OF WATER SERVICE AND BUILDING SEWER FIGURE 603.2(2) WATER SERVICE CROSSING OVER BUILDING SEWER FIGURE 603.2(2) WATER SERVICE CROSSING OVER BUILDING SEWER |
156 | TABLE 603.2.1 MINIMUM HORIZONTAL SEPARATION DISTANCES BETWEEN WATER SOURCE ELEMENTS AND SOIL ABSORPTION SYSTEM COMPONENTS TABLE 603.2.1 MINIMUM HORIZONTAL SEPARATION DISTANCES BETWEEN WATER SOURCE ELEMENTS AND SOIL ABSORPTION SYSTEM COMPONENTS SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM |
157 | FIGURE 604.1(1) DIFFERENCE IN ELEVATION FIGURE 604.1(1) DIFFERENCE IN ELEVATION FIGURE 604.1(2) DIFFERENCE IN ELEVATION FIGURE 604.1(2) DIFFERENCE IN ELEVATION |
158 | FIGURE 604.1(3) CAVITATION FIGURE 604.1(3) CAVITATION TABLE 604.1 MAXIMUM FLOW VELOCITY TABLE 604.1 MAXIMUM FLOW VELOCITY |
160 | TABLE 604.3 PEAK DEMAND PERIODS TABLE 604.3 PEAK DEMAND PERIODS TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS |
161 | TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS |
162 | FIGURE 604.5 WATER SUPPLY CONNECTION WITH REDUCED-SIZE FLEXIBLE SUPPLY FIGURE 604.5 WATER SUPPLY CONNECTION WITH REDUCED-SIZE FLEXIBLE SUPPLY TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES |
164 | FIGURE 604.9(1) EXAMPLE OF MECHANICAL WATER-HAMMER ARRESTORS FIGURE 604.9(1) EXAMPLE OF MECHANICAL WATER-HAMMER ARRESTORS |
165 | FIGURE 604.9(2) AIR CHAMBER WATER HAMMER ARRESTOR FIGURE 604.9(2) AIR CHAMBER WATER HAMMER ARRESTOR FIGURE 604.10 FACTORY BUILT MANIFOLD FOR PARALLEL DISTRIBUTION FIGURE 604.10 FACTORY BUILT MANIFOLD FOR PARALLEL DISTRIBUTION |
166 | TABLE 604.10.1 MANIFOLD SIZING TABLE 604.10.1 MANIFOLD SIZING SECTION 605 MATERIALS, JOINTS AND CONNECTIONS SECTION 605 MATERIALS, JOINTS AND CONNECTIONS |
167 | TABLE 605.3 WATER SERVICE PIPE TABLE 605.3 WATER SERVICE PIPE |
168 | FIGURE 605.3(1) PLASTIC WATER SERVICE EXTENDING INTO BUILDING FIGURE 605.3(1) PLASTIC WATER SERVICE EXTENDING INTO BUILDING |
169 | FIGURE 605.3(2) PLASTIC WATER SERVICE EXTENDING INTO BUILDING FIGURE 605.3(2) PLASTIC WATER SERVICE EXTENDING INTO BUILDING |
172 | FIGURE 605.3(3) SAMPLE MARKING OF PEX TUBING FIGURE 605.3(3) SAMPLE MARKING OF PEX TUBING |
175 | TABLE 605.4 WATER DISTRIBUTION PIPE TABLE 605.4 WATER DISTRIBUTION PIPE |
176 | TABLE 605.5 PIPE FITTINGS TABLE 605.5 PIPE FITTINGS |
177 | TABLE 605.8 MANUFACTURED PIPE NIPPLES TABLE 605.8 MANUFACTURED PIPE NIPPLES |
178 | FIGURE 605.11 ASBESTOS-CEMENT PIPE JOINT FIGURE 605.11 ASBESTOS-CEMENT PIPE JOINT |
179 | FIGURE 605.12.1 HEAT APPLICATION OF BRAZED JOINT FIGURE 605.12.1 HEAT APPLICATION OF BRAZED JOINT |
180 | FIGURE 605.14.3 PREPARATION OF PIPE END FIGURE 605.14.3 PREPARATION OF PIPE END |
182 | FIGURE 605.15.2(1) TYPICAL FLARED JOINT FIGURE 605.15.2(1) TYPICAL FLARED JOINT FIGURE 605.15.2(2) TYPICAL FLARED JOINT FIGURE 605.15.2(2) TYPICAL FLARED JOINT |
185 | FIGURE 605.20.4 BENDING FIGURE 605.20.4 BENDING |
187 | TABLE 605.24.1 CORROSIVE HIERARCHY OF METALS (Galvanic Series) TABLE 605.24.1 CORROSIVE HIERARCHY OF METALS (Galvanic Series) FIGURE 605.24.1(1) DIELECTRIC UNION FIGURE 605.24.1(1) DIELECTRIC UNION |
188 | FIGURE 605.24.1(2) DIELECTRIC FLANGE FITTING FIGURE 605.24.1(2) DIELECTRIC FLANGE FITTING SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM |
189 | FIGURE 606.1(1) CURB VALVE ON WATER SUPPLY FIGURE 606.1(1) CURB VALVE ON WATER SUPPLY FIGURE 606.1(2) VALVE AT ENTRANCE TO THE BUILDING AND ON THE DISCHARGE SIDE OF METER FIGURE 606.1(2) VALVE AT ENTRANCE TO THE BUILDING AND ON THE DISCHARGE SIDE OF METER |
190 | FIGURE 606.1(3) VALVES FOR EACH RISER AND DOWNFEED FIGURE 606.1(3) VALVES FOR EACH RISER AND DOWNFEED FIGURE 606.1(4) DWELLING UNIT VALVE FIGURE 606.1(4) DWELLING UNIT VALVE FIGURE 606.1(5) VALVES ON SUPPLY TO EACH TANK FIGURE 606.1(5) VALVES ON SUPPLY TO EACH TANK |
191 | FIGURE 606.1(6) WATER HEATER VALVE FIGURE 606.1(6) WATER HEATER VALVE |
192 | FIGURE 606.2(1) SHUTOFF VALVES FOR EACH FIXTURE FIGURE 606.2(1) SHUTOFF VALVES FOR EACH FIXTURE FIGURE 606.2(2) SILL FAUCET VALVE FIGURE 606.2(2) SILL FAUCET VALVE |
193 | TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS |
194 | SECTION 607 HOT WATER SUPPLY SYSTEM SECTION 607 HOT WATER SUPPLY SYSTEM |
195 | FIGURE 607.2 HOT WATER SUPPLY TEMPERATURE MAINTENANCE FIGURE 607.2 HOT WATER SUPPLY TEMPERATURE MAINTENANCE |
196 | FIGURE 607.3 EXAMPLE METHOD OF THERMAL EXPANSION CONTROL FIGURE 607.3 EXAMPLE METHOD OF THERMAL EXPANSION CONTROL |
197 | FIGURE 607.3.1 PRESSURE-REDUCING VALVE WITH THERMAL EXPANSION BYPASS FIGURE 607.3.1 PRESSURE-REDUCING VALVE WITH THERMAL EXPANSION BYPASS |
198 | SECTION 608 PROTECTION OF POTABLE WATER SUPPLY SECTION 608 PROTECTION OF POTABLE WATER SUPPLY |
199 | TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS |
200 | FIGURE 608.1(1) ATMOSPHERIC PRESSURE FIGURE 608.1(1) ATMOSPHERIC PRESSURE FIGURE 608.1(2) PRESSURE EXERTED BY 1 CUBIC FOOT OF WATER FIGURE 608.1(2) PRESSURE EXERTED BY 1 CUBIC FOOT OF WATER |
201 | FIGURE 608.1(3) PRESSURE EXERTED BY A COLUMN OF WATER FIGURE 608.1(3) PRESSURE EXERTED BY A COLUMN OF WATER |
202 | FIGURE 608.1(4) BASE PRESSURE FIGURE 608.1(4) BASE PRESSURE FIGURE 608.1(5) COLUMN OF WATER EXPOSED TO ATMOSPHERE FIGURE 608.1(5) COLUMN OF WATER EXPOSED TO ATMOSPHERE FIGURE 608.1(6) OPEN TUBE INSERTED IN CONTAINER OF WATER FIGURE 608.1(6) OPEN TUBE INSERTED IN CONTAINER OF WATER |
203 | FIGURE 608.1(7) VACUUM APPLIED TO A SEALED TUBE INSERTED IN ACONTAINER OF WATER FIGURE 608.1(7) VACUUM APPLIED TO A SEALED TUBE INSERTED IN ACONTAINER OF WATER FIGURE 608.1(8) EXAMPLE OF SIMPLE SIPHON FIGURE 608.1(8) EXAMPLE OF SIMPLE SIPHON FIGURE 608.1(9) EXAMPLE OF ASPIRATION OR VENTURE PRINCIPLE FIGURE 608.1(9) EXAMPLE OF ASPIRATION OR VENTURE PRINCIPLE |
204 | FIGURE 608.1(10) EXAMPLE OF PUMP CAUSING NEGATIVE PRESSURE FIGURE 608.1(10) EXAMPLE OF PUMP CAUSING NEGATIVE PRESSURE |
205 | FIGURE 608.6.1 CONNECTION BETWEEN TWO SYSTEMS FIGURE 608.6.1 CONNECTION BETWEEN TWO SYSTEMS |
206 | TABLE 608.8 IDENTIFICATION COLOR TABLE 608.8 IDENTIFICATION COLOR FIGURE 608.7(1) YARD HYDRANT WITH STOP AND WASTE VALVE FIGURE 608.7(1) YARD HYDRANT WITH STOP AND WASTE VALVE TABLE 608.8.3 SIZE OF PIPE IDENTIFICATION TABLE 608.8.3 SIZE OF PIPE IDENTIFICATION |
207 | FIGURE 608.7(2) PROHIBITED INSTALLATION OF YARD HYDRANTS CONNECTED TO WATER SERVICE LINES FIGURE 608.7(2) PROHIBITED INSTALLATION OF YARD HYDRANTS CONNECTED TO WATER SERVICE LINES FIGURE 608.8 IDENTIFICATION OF PIPING SYSTEMS FIGURE 608.8 IDENTIFICATION OF PIPING SYSTEMS |
210 | FIGURE 608.13.4 BAROMETRIC LOOP FIGURE 608.13.4 BAROMETRIC LOOP FIGURE 608.13.5 PRESSURE VACUUM BREAKER FIGURE 608.13.5 PRESSURE VACUUM BREAKER |
211 | FIGURE 608.13.7 DOUBLE CHECK-VALVE ASSEMBLY FIGURE 608.13.7 DOUBLE CHECK-VALVE ASSEMBLY |
213 | TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS |
214 | FIGURE 608.15.1(1) AIR GAP FOR A LAVATORY FAUCET FIGURE 608.15.1(1) AIR GAP FOR A LAVATORY FAUCET FIGURE 608.15.1(2) AIR GAP PIPING SYSTEM FIGURE 608.15.1(2) AIR GAP PIPING SYSTEM FIGURE 608.15.1(3) AIR GAPS-LOCATED NEAR SINGLE WALL FIGURE 608.15.1(3) AIR GAPS-LOCATED NEAR SINGLE WALL |
215 | FIGURE 608.15.1(4) AIR GAPS-LOCATED NEAR INTERSECTING WALLS FIGURE 608.15.1(4) AIR GAPS-LOCATED NEAR INTERSECTING WALLS FIGURE 608.15.4(1) VACUUM BREAKER FOR HAND HELD SHOWER FIGURE 608.15.4(1) VACUUM BREAKER FOR HAND HELD SHOWER |
216 | FIGURE 608.15.4(2) SUBMERGED INLET PROTECTED BY VACUUM BREAKER FIGURE 608.15.4(2) SUBMERGED INLET PROTECTED BY VACUUM BREAKER |
217 | FIGURE 608.15.4.2(1) HOSE (SILL) FAUCET WITHOUT VACUUM BREAKER FIGURE 608.15.4.2(1) HOSE (SILL) FAUCET WITHOUT VACUUM BREAKER FIGURE 608.15.4.2(2) HOSE (SILL) FREEZEPROOF FAUCET WITH INTEGRAL ANTISIPHON DEVICES FIGURE 608.15.4.2(2) HOSE (SILL) FREEZEPROOF FAUCET WITH INTEGRAL ANTISIPHON DEVICES |
218 | FIGURE 608.15.4.2(3) HOSE CONNECTION VACUUM BREAKER FIGURE 608.15.4.2(3) HOSE CONNECTION VACUUM BREAKER FIGURE 608.16.1 BEVERAGE DISPENSER FIGURE 608.16.1 BEVERAGE DISPENSER |
219 | FIGURE 608.16.2 FOR BOILER WITHOUT CONDITIONING CHEMICALS FIGURE 608.16.2 FOR BOILER WITHOUT CONDITIONING CHEMICALS |
220 | TABLE 608.16.3(1) GOSSELIN RATINGS TABLE 608.16.3(1) GOSSELIN RATINGS TABLE 608.16.3(2) HEAT TRANSFER FLUIDS (ESSENTIALLYNONTOXIC) GOSSELIN RATING OF TABLE 608.16.3(2) HEAT TRANSFER FLUIDS (ESSENTIALLYNONTOXIC) GOSSELIN RATING OF FIGURE 608.16.3 DOUBLE WALL HEAT EXCHANGER FIGURE 608.16.3 DOUBLE WALL HEAT EXCHANGER |
221 | FIGURE 608.16.4(1) COMBINATION WATER DISTRIBUTION/AUTOMATIC SPRINKLER SYSTEM FIGURE 608.16.4(1) COMBINATION WATER DISTRIBUTION/AUTOMATIC SPRINKLER SYSTEM |
222 | FIGURE 608.16.4(2) COMMON FIRE SPRINKLER AND DOMESTIC WATER SUPPLY FIGURE 608.16.4(2) COMMON FIRE SPRINKLER AND DOMESTIC WATER SUPPLY |
224 | FIGURE 608.16.6 REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER FIGURE 608.16.6 REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER |
225 | TABLE 608.17.1 DISTANCE FROM CONTAMINATION TOPRIVATE WATER SUPPLIES AND PUMP SUCTION LINES TABLE 608.17.1 DISTANCE FROM CONTAMINATION TOPRIVATE WATER SUPPLIES AND PUMP SUCTION LINES FIGURE 608.17.3 DEPTH OF WELL FIGURE 608.17.3 DEPTH OF WELL |
226 | FIGURE 608.17.4 WELL CASING FIGURE 608.17.4 WELL CASING FIGURE 608.17.5 CASING FOR DRILLED OR DRIVEN WELL FIGURE 608.17.5 CASING FOR DRILLED OR DRIVEN WELL FIGURE 608.17.7 DUG WELL COVER FIGURE 608.17.7 DUG WELL COVER |
227 | SECTION 609 HEALTH CARE PLUMBING SECTION 609 HEALTH CARE PLUMBING FIGURE 609.2 DUAL WATER SERVICE FOR HOSPITALS FIGURE 609.2 DUAL WATER SERVICE FOR HOSPITALS |
228 | SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM |
229 | SECTION 611 DRINKING WATER TREATMENT UNITS SECTION 611 DRINKING WATER TREATMENT UNITS SECTION 612 SOLAR SYSTEMS SECTION 612 SOLAR SYSTEMS |
230 | SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES BIBLIOGRAPHY BIBLIOGRAPHY |
234 | CHAPTER 7: SANITARY DRAINAGE CHAPTER 7: SANITARY DRAINAGE GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION 701 GENERAL SECTION 701 GENERAL |
235 | FIGURE 701.3(1) COMMON BUILDING SEWER LOCATED WITHIN AN APPROVED PUBLIC SEWER EASEMENT FIGURE 701.3(1) COMMON BUILDING SEWER LOCATED WITHIN AN APPROVED PUBLIC SEWER EASEMENT |
236 | FIGURE 701.3(2) BUILDING ON SAME LOT FIGURE 701.3(2) BUILDING ON SAME LOT SECTION 702 MATERIALS SECTION 702 MATERIALS |
237 | TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE |
239 | TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE |
240 | TABLE 702.3 BUILDING SEWER PIPE TABLE 702.3 BUILDING SEWER PIPE |
241 | SECTION 703 BUILDING SEWER SECTION 703 BUILDING SEWER TABLE 702.4 PIPE FITTINGS TABLE 702.4 PIPE FITTINGS |
242 | SECTION 704 DRAINAGE PIPING INSTALLATION SECTION 704 DRAINAGE PIPING INSTALLATION TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE |
243 | FIGURE 704.3 HYDRAULIC JUMP FIGURE 704.3 HYDRAULIC JUMP SECTION 705 JOINTS SECTION 705 JOINTS |
244 | FIGURE 705.3 ASBESTOS-CEMENT PIPE JOINT FIGURE 705.3 ASBESTOS-CEMENT PIPE JOINT |
245 | FIGURE 705.4.1 HEAT APPLICATION OF BRAZED JOINT FIGURE 705.4.1 HEAT APPLICATION OF BRAZED JOINT |
246 | FIGURE 705.5.1 CAULKED JOINT FOR HUB AND SPIGOT (CAST-IRON) FIGURE 705.5.1 CAULKED JOINT FOR HUB AND SPIGOT (CAST-IRON) |
247 | FIGURE 705.5.2 CAST-IRON COMPRESSION GASKET FIGURE 705.5.2 CAST-IRON COMPRESSION GASKET FIGURE 705.5.3 HUBLESS CAST-IRON DRAINAGE PIPE JOINT FIGURE 705.5.3 HUBLESS CAST-IRON DRAINAGE PIPE JOINT FIGURE 705.6 CONCRETE MECHANICAL JOINT FIGURE 705.6 CONCRETE MECHANICAL JOINT |
249 | FIGURE 705.9.3 PREPARATION OF PIPE END FIGURE 705.9.3 PREPARATION OF PIPE END |
251 | FIGURE 705.13.2 LEAD-WIPED JOINT FIGURE 705.13.2 LEAD-WIPED JOINT |
253 | FIGURE 705.18.3 CAST-IRON ADAPTER FITTING FIGURE 705.18.3 CAST-IRON ADAPTER FITTING |
254 | FIGURE 705.19(1) SLIP JOINT FIGURE 705.19(1) SLIP JOINT FIGURE 705.19(2) SLIP JOINTS FIGURE 705.19(2) SLIP JOINTS |
255 | TABLE 705.20 CAULKING FERRULE SPECIFICATIONS TABLE 705.20 CAULKING FERRULE SPECIFICATIONS TABLE 705.21 SOLDERING BUSHING SPECIFICATIONS TABLE 705.21 SOLDERING BUSHING SPECIFICATIONS SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS |
256 | TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION |
257 | FIGURE 706.3(1) COMPARISON OF DIFFERENT 11/2-INCH LONG SWEEPS FOR VARIOUS PIPING MATERIALS FIGURE 706.3(1) COMPARISON OF DIFFERENT 11/2-INCH LONG SWEEPS FOR VARIOUS PIPING MATERIALS FIGURE 706.3(2) COMPARISON OF 3-INCH COMBINATION WYE AND EIGHTH BEND FOR VARIOUS PIPING MATERIALS FIGURE 706.3(2) COMPARISON OF 3-INCH COMBINATION WYE AND EIGHTH BEND FOR VARIOUS PIPING MATERIALS |
258 | FIGURE 706.3(3) DRAINAGE PATTERN FITTINGS FIGURE 706.3(3) DRAINAGE PATTERN FITTINGS |
260 | FIGURE 706.3(4) DIFFERENCE BETWEEN PVC PLASTIC 1/4-BEND SHORT SWEEP AND 1/4-BEND VENT FIGURE 706.3(4) DIFFERENCE BETWEEN PVC PLASTIC 1/4-BEND SHORT SWEEP AND 1/4-BEND VENT FIGURE 706.3(5) BACK-TO-BACK FIXTURES FIGURE 706.3(5) BACK-TO-BACK FIXTURES FIGURE 706.3(6) HEEL INLET FITTINGS FIGURE 706.3(6) HEEL INLET FITTINGS |
261 | FIGURE 706.3(7) COMBINATION TEES FIGURE 706.3(7) COMBINATION TEES FIGURE 706.3(8) FITTING USES FIGURE 706.3(8) FITTING USES |
262 | FIGURE 706.3(9) IMPROPER USE OF DWV-PVC/ABS 90 DEGREE FITTINGS FIGURE 706.3(9) IMPROPER USE OF DWV-PVC/ABS 90 DEGREE FITTINGS |
263 | FIGURE 706.3(10) PROPER USE OF DWV-PVC/ABS 90 DEGREE FITTINGS FIGURE 706.3(10) PROPER USE OF DWV-PVC/ABS 90 DEGREE FITTINGS FIGURE 706.4(1) HEEL- AND SIDE-INLET QUARTER BEND APPLICATION RESTRICTIONS FIGURE 706.4(1) HEEL- AND SIDE-INLET QUARTER BEND APPLICATION RESTRICTIONS SECTION 707 PROHIBITED JOINTS AND CONNECTIONS SECTION 707 PROHIBITED JOINTS AND CONNECTIONS |
264 | FIGURE 706.4(2) SIDE-INLET QUARTER BEND FOR WATER CLOSET FIGURE 706.4(2) SIDE-INLET QUARTER BEND FOR WATER CLOSET SECTION 708 CLEANOUTS SECTION 708 CLEANOUTS |
265 | FIGURE 708.1 ACCEPTABLE CLEANOUTS FIGURE 708.1 ACCEPTABLE CLEANOUTS |
266 | FIGURE 708.2 CLEANOUT INSTALLATIONS FIGURE 708.2 CLEANOUT INSTALLATIONS FIGURE 708.3.1 CLEANOUT LOCATIONS FIGURE 708.3.1 CLEANOUT LOCATIONS |
267 | FIGURE 708.3.2(1) CLEANOUTS IN BUILDING SEWER—LIMITATIONS FIGURE 708.3.2(1) CLEANOUTS IN BUILDING SEWER—LIMITATIONS FIGURE 708.3.2(2) MANHOLE LOCATIONS FIGURE 708.3.2(2) MANHOLE LOCATIONS |
268 | FIGURE 708.3.3 CLEANOUTS FIGURE 708.3.3 CLEANOUTS |
269 | FIGURE 708.3.4 CLEANOUTS BASE OF STACK FIGURE 708.3.4 CLEANOUTS BASE OF STACK FIGURE 708.3.5(1) CLEANOUTS AT SEWER JUNCTION FIGURE 708.3.5(1) CLEANOUTS AT SEWER JUNCTION |
270 | FIGURE 708.3.5(2) TWO-WAY CLEANOUT FITTING FIGURE 708.3.5(2) TWO-WAY CLEANOUT FITTING FIGURE 708.3.6 MANHOLES INSIDE THE BUILDING FIGURE 708.3.6 MANHOLES INSIDE THE BUILDING |
271 | FIGURE 708.4 CLEANOUTS ON CONCEALED PIPING FIGURE 708.4 CLEANOUTS ON CONCEALED PIPING |
272 | TABLE 708.7 CLEANOUT SIZES TABLE 708.7 CLEANOUT SIZES FIGURE 708.8 CLEARANCE FOR CLEANOUTS FIGURE 708.8 CLEARANCE FOR CLEANOUTS SECTION 709 FIXTURE UNITS SECTION 709 FIXTURE UNITS |
274 | TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS |
275 | TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS SECTION 710 DRAINAGE SYSTEM SIZING SECTION 710 DRAINAGE SYSTEM SIZING |
276 | TABLE 710.1(1) BUILDING DRAINS AND SEWERS TABLE 710.1(1) BUILDING DRAINS AND SEWERS |
277 | FIGURE 710.1(1) BUILDING DRAIN SIZING FIGURE 710.1(1) BUILDING DRAIN SIZING TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa |
278 | TABLE 710.1(1) HORIZONTAL BRANCH CAPACITY TABLE 710.1(1) HORIZONTAL BRANCH CAPACITY FIGURE 710.1(2) HORIZONTAL BRANCH (Complete venting not shown) FIGURE 710.1(2) HORIZONTAL BRANCH (Complete venting not shown) TABLE 710.1(2) STACK CAPACITIES TABLE 710.1(2) STACK CAPACITIES |
279 | FIGURE 710.1(3) STACK SIZING FIGURE 710.1(3) STACK SIZING TABLE 710.1(3) ALLOWABLE STACK DRAINAGE FIXTURE UNITS TABLE 710.1(3) ALLOWABLE STACK DRAINAGE FIXTURE UNITS |
280 | FIGURE 710.1(4) EXAMPLE OF SIZING STACK GREATER THAN THREE BRANCH INTERVALS FIGURE 710.1(4) EXAMPLE OF SIZING STACK GREATER THAN THREE BRANCH INTERVALS FIGURE 710.1(5) SIZING OF STACK THREE BRANCH INTERVALS OR LESS FIGURE 710.1(5) SIZING OF STACK THREE BRANCH INTERVALS OR LESS |
281 | FIGURE 710.1(6) FLOW IN A STACK FIGURE 710.1(6) FLOW IN A STACK FIGURE 710.1(7) REDUCING SIZE OF DRAINAGE STACK FIGURE 710.1(7) REDUCING SIZE OF DRAINAGE STACK SECTION 711 OFFSETS IN DRAINAGE PIPING INBUILDINGS OF FIVE STORIES OR MORE SECTION 711 OFFSETS IN DRAINAGE PIPING INBUILDINGS OF FIVE STORIES OR MORE |
282 | FIGURE 711.1 VERTICAL STACK OFFSET FIGURE 711.1 VERTICAL STACK OFFSET FIGURE 711.2 HORIZONTAL STACK OFFSET FIGURE 711.2 HORIZONTAL STACK OFFSET |
283 | FIGURE 711.3 OFFSET SIZING FIGURE 711.3 OFFSET SIZING |
284 | FIGURE 711.4(1) OFFSET SIZING FIGURE 711.4(1) OFFSET SIZING FIGURE 711.4(2) OFFSET SIZING FIGURE 711.4(2) OFFSET SIZING SECTION 712 SUMPS AND EJECTORS SECTION 712 SUMPS AND EJECTORS |
285 | FIGURE 712.1(1) PNEUMATIC SEWAGE EJECTOR FIGURE 712.1(1) PNEUMATIC SEWAGE EJECTOR FIGURE 712.1(2) MECHANICAL SEWAGE PUMP FIGURE 712.1(2) MECHANICAL SEWAGE PUMP |
286 | FIGURE 712.2 SEWAGE EJECTOR INSTALLATION FIGURE 712.2 SEWAGE EJECTOR INSTALLATION |
288 | FIGURE 712.4.1(1) MACERATING TOILET SYSTEMS FIGURE 712.4.1(1) MACERATING TOILET SYSTEMS FIGURE 712.4.1(2) MACERATING TOILET SYSTEMS FIGURE 712.4.1(2) MACERATING TOILET SYSTEMS |
289 | TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR SECTION 713 HEALTH CARE PLUMBING SECTION 713 HEALTH CARE PLUMBING |
290 | FIGURE 713.3 COMMON INDIRECT WASTE PIPE FOR STERILIZERS FIGURE 713.3 COMMON INDIRECT WASTE PIPE FOR STERILIZERS |
291 | FIGURE 713.6 CENTRAL VACUUM SYSTEM FIGURE 713.6 CENTRAL VACUUM SYSTEM |
292 | TABLE 713.9.1 MULTIPLE CONNECTION FOR BEDPAN WASHERS TO LOCAL VENT STACK TABLE 713.9.1 MULTIPLE CONNECTION FOR BEDPAN WASHERS TO LOCAL VENT STACK FIGURE 713.9.1 LOCAL VENT STACK FIGURE 713.9.1 LOCAL VENT STACK |
293 | FIGURE 713.9.2 BOTTOM CONNECTION TO LOCAL VENT STACK FIGURE 713.9.2 BOTTOM CONNECTION TO LOCAL VENT STACK TABLE 713.11.1 STACK SIZES FOR BEDPAN STEAMERS ANDBOILING-TYPE STERILIZERS (Number of Connections of Various SizesPermitted to Various-sized Sterilizer Vent Stacks) TABLE 713.11.1 STACK SIZES FOR BEDPAN STEAMERS ANDBOILING-TYPE STERILIZERS (Number of Connections of Various SizesPermitted to Various-sized Sterilizer Vent Stacks) |
294 | FIGURE 713.10 STERILIZER PIPING FIGURE 713.10 STERILIZER PIPING TABLE 713.11.3 STACK SIZES FOR PRESSURE STERILIZERS(Number of Connections of Various Sizes TABLE 713.11.3 STACK SIZES FOR PRESSURE STERILIZERS(Number of Connections of Various Sizes TABLE 713.11.4 PRESSURE INSTRUMENT WASHER STERILIZER SIZES TABLE 713.11.4 PRESSURE INSTRUMENT WASHER STERILIZER SIZES |
295 | SECTION 714 COMPUTERIZED DRAINAGE DESIGN SECTION 714 COMPUTERIZED DRAINAGE DESIGN SECTION 715 BACKWATER VALVES SECTION 715 BACKWATER VALVES |
296 | FIGURE 715.1(1) BACKWATER VALVE FIGURE 715.1(1) BACKWATER VALVE FIGURE 715.1(2) BACKWATER VALVES FIGURE 715.1(2) BACKWATER VALVES |
297 | BIBLIOGRAPHY BIBLIOGRAPHY |
300 | CHAPTER 8: INDIRECT/SPECIAL WASTE CHAPTER 8: INDIRECT/SPECIAL WASTE GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION 801 GENERAL SECTION 801 GENERAL SECTION 802 INDIRECT WASTES SECTION 802 INDIRECT WASTES |
301 | FIGURE 802.1.1(1) THREE-COMPARTMENT FOOD PREPARATION SINK FIGURE 802.1.1(1) THREE-COMPARTMENT FOOD PREPARATION SINK |
302 | FIGURE 802.1.1(2) REFRIGERATED FOOD CASE DISCHARGING TO HUB DRAIN FIGURE 802.1.1(2) REFRIGERATED FOOD CASE DISCHARGING TO HUB DRAIN FIGURE 802.1.1(3) RESTAURANT KITCHEN INDIRECT WASTE FIGURE 802.1.1(3) RESTAURANT KITCHEN INDIRECT WASTE |
303 | FIGURE 802.1.2 FLOOR DRAIN IN FOOD STORAGE FREEZER FIGURE 802.1.2 FLOOR DRAIN IN FOOD STORAGE FREEZER FIGURE 802.1.3 INDIRECT WASTE FIGURE 802.1.3 INDIRECT WASTE |
304 | FIGURE 802.1.5 INDIRECT WASTE—CLEAR-WATER WASTE FIGURE 802.1.5 INDIRECT WASTE—CLEAR-WATER WASTE |
305 | FIGURE 802.1.6 RESIDENTIAL DISHWASHER WASTE CONNECTIONS FIGURE 802.1.6 RESIDENTIAL DISHWASHER WASTE CONNECTIONS FIGURE 802.1.7 COMMERCIAL DISHWASHER WASTE CONNECTION FIGURE 802.1.7 COMMERCIAL DISHWASHER WASTE CONNECTION |
306 | FIGURE 802.2 TRAPS FOR INDIRECT WASTE PIPES FIGURE 802.2 TRAPS FOR INDIRECT WASTE PIPES |
307 | FIGURE 802.2.1 AIR GAP FIGURE 802.2.1 AIR GAP FIGURE 802.2.2(1) AIR BREAK FIGURE 802.2.2(1) AIR BREAK FIGURE 802.2.2(2) AIR BREAK FIGURE 802.2.2(2) AIR BREAK |
308 | FIGURE 802.3(1) WASTE RECEPTORS FIGURE 802.3(1) WASTE RECEPTORS FIGURE 802.3(2) WASTE RECEPTORS FIGURE 802.3(2) WASTE RECEPTORS |
309 | FIGURE 802.3.1(1) SHALLOW, FLAT BOTTOM WASTE RECEPTOR FIGURE 802.3.1(1) SHALLOW, FLAT BOTTOM WASTE RECEPTOR FIGURE 802.3.1(2) SIZE AND SHAPE OF WASTE RECEPTOR FIGURE 802.3.1(2) SIZE AND SHAPE OF WASTE RECEPTOR SECTION 803 SPECIAL WASTES SECTION 803 SPECIAL WASTES |
310 | FIGURE 802.3.2 CLEAR-WATER WASTE RECEPTOR FIGURE 802.3.2 CLEAR-WATER WASTE RECEPTOR FIGURE 802.4 STANDPIPES FIGURE 802.4 STANDPIPES |
311 | SECTION 804 MATERIALS, JOINTS AND CONNECTIONS SECTION 804 MATERIALS, JOINTS AND CONNECTIONS BIBLIOGRAPHY BIBLIOGRAPHY |
312 | CHAPTER 9: VENTS CHAPTER 9: VENTS GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION 901 GENERAL SECTION 901 GENERAL |
313 | FIGURE 901.2(1) LOSS OF TRAP SEAL FIGURE 901.2(1) LOSS OF TRAP SEAL FIGURE 901.2(2) MAXIMUM TRAP SEAL RESISTANCE FIGURE 901.2(2) MAXIMUM TRAP SEAL RESISTANCE |
314 | SECTION 902 MATERIALS SECTION 902 MATERIALS SECTION 903 OUTDOOR VENT EXTENSION SECTION 903 OUTDOOR VENT EXTENSION |
315 | FIGURE 903.1(1) REDUCTION OF STACK VENT CONNECTION FIGURE 903.1(1) REDUCTION OF STACK VENT CONNECTION FIGURE 903.1(2) STACK VENT FIGURE 903.1(2) STACK VENT |
316 | FIGURE 903.1(3) REQUIRED VENT TO OUTDOORS FIGURE 903.1(3) REQUIRED VENT TO OUTDOORS |
318 | FIGURE 903.4 VENT CONNECTION AT BASE FIGURE 903.4 VENT CONNECTION AT BASE FIGURE 903.5 VENT HEADERS FIGURE 903.5 VENT HEADERS |
319 | SECTION 904 VENT TERMINALS SECTION 904 VENT TERMINALS FIGURE 904.1 VENT TERMINAL FIGURE 904.1 VENT TERMINAL |
320 | FIGURE 904.5 SEPARATION OF VENT TERMINAL FIGURE 904.5 SEPARATION OF VENT TERMINAL |
321 | FIGURE 904.6 SIDEWALL VENT FIGURE 904.6 SIDEWALL VENT SECTION 905 VENT CONNECTIONS AND GRADES SECTION 905 VENT CONNECTIONS AND GRADES |
322 | FIGURE 905.2 GRADE OF VENTS FIGURE 905.2 GRADE OF VENTS FIGURE 905.3 VENT CONNECTIONS FIGURE 905.3 VENT CONNECTIONS |
323 | FIGURE 905.4 VERTICAL RISE OF VENT FIGURE 905.4 VERTICAL RISE OF VENT |
324 | FIGURE 905.5(1) IMPROPERLY CONNECTED VENT SERVING A DRAIN FIGURE 905.5(1) IMPROPERLY CONNECTED VENT SERVING A DRAIN FIGURE 905.5(2) PROPERLY CONNECTED VENT SERVING A DRAIN FIGURE 905.5(2) PROPERLY CONNECTED VENT SERVING A DRAIN FIGURE 905.5(3) HORIZONTAL BRANCH VENT ELEVATION FIGURE 905.5(3) HORIZONTAL BRANCH VENT ELEVATION |
325 | SECTION 906 FIXTURE VENTS SECTION 906 FIXTURE VENTS TABLE 906.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT TABLE 906.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT |
326 | FIGURE 906.1(1) DISTANCE FROM TRAP TO VENT FIGURE 906.1(1) DISTANCE FROM TRAP TO VENT SECTION 907 INDIVIDUAL VENT SECTION 907 INDIVIDUAL VENT |
327 | FIGURE 906.1(2) MAXIMUM FALL OF FIXTURE DRAIN BETWEEN TRAP AND VENT FIGURE 906.1(2) MAXIMUM FALL OF FIXTURE DRAIN BETWEEN TRAP AND VENT FIGURE 906.1(3) TRAP TO VENT DISTANCE FOR WATER CLOSETS FIGURE 906.1(3) TRAP TO VENT DISTANCE FOR WATER CLOSETS |
328 | FIGURE 906.2(1) VENT CONNECTION FIGURE 906.2(1) VENT CONNECTION FIGURE 906.2(2) SELF-SIPHONING PHENOMENON FIGURE 906.2(2) SELF-SIPHONING PHENOMENON |
329 | FIGURE 906.3(1) CROWN VENTING FIGURE 906.3(1) CROWN VENTING FIGURE 906.3(2) CROWN VENTING FIGURE 906.3(2) CROWN VENTING |
330 | FIGURE 907.1(1) INDIVIDUAL VENTS FIGURE 907.1(1) INDIVIDUAL VENTS FIGURE 907.1(2) IMPROPERLY INSTALLED INDIVIDUAL VENTS FIGURE 907.1(2) IMPROPERLY INSTALLED INDIVIDUAL VENTS SECTION 908 COMMON VENT SECTION 908 COMMON VENT |
331 | FIGURE 908.1 COMMON VENTS FIGURE 908.1 COMMON VENTS TABLE 908.3 COMMON VENT SIZES TABLE 908.3 COMMON VENT SIZES SECTION 909 WET VENTING SECTION 909 WET VENTING |
332 | FIGURE 908.2 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT SAME LEVEL FIGURE 908.2 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT SAME LEVEL |
333 | FIGURE 908.3 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT DIFFERENT LEVELS FIGURE 908.3 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT DIFFERENT LEVELS |
334 | FIGURE 909.1(1) MULTIFLOOR WET VENTING FIGURE 909.1(1) MULTIFLOOR WET VENTING FIGURE 909.1(2) SINGLE BATHROOM GROUP (PRIVATE) WET VENT FIGURE 909.1(2) SINGLE BATHROOM GROUP (PRIVATE) WET VENT FIGURE 909.1(3) DOUBLE BATHROOM GROUP (PRIVATE) WET VENT FIGURE 909.1(3) DOUBLE BATHROOM GROUP (PRIVATE) WET VENT FIGURE 909.1(4) VERTICAL WET VENTING(PRIVATE BATHROOM GROUP) FIGURE 909.1(4) VERTICAL WET VENTING(PRIVATE BATHROOM GROUP) |
335 | FIGURE 909.1(5) WET VENT VARIATIONS FOR ASINGLE BATHROOM GROUP FIGURE 909.1(5) WET VENT VARIATIONS FOR ASINGLE BATHROOM GROUP FIGURE 909.1(6) TWO BATHROOM GROUPS FIGURE 909.1(6) TWO BATHROOM GROUPS FIGURE 909.1(7) WET VENTING FIGURE 909.1(7) WET VENTING FIGURE 909.1(8) WET VENTING FIGURE 909.1(8) WET VENTING |
336 | FIGURE 909.1(9) WET VENTING FIGURE 909.1(9) WET VENTING FIGURE 909.1(10) WET VENTING FIGURE 909.1(10) WET VENTING |
337 | FIGURE 909.1(11) MULTIPLE INDIVIDUAL VENTS FIGURE 909.1(11) MULTIPLE INDIVIDUAL VENTS |
338 | FIGURE 909.1(12) PROHIBITED WET VENTING FIGURE 909.1(12) PROHIBITED WET VENTING |
339 | TABLE 909.3 WET VENT SIZE TABLE 909.3 WET VENT SIZE SECTION 910 WASTE STACK VENT SECTION 910 WASTE STACK VENT |
340 | FIGURE 910.2(1) WASTE STACK VENT FIGURE 910.2(1) WASTE STACK VENT TABLE 910.4 WASTE STACK VENT SIZE TABLE 910.4 WASTE STACK VENT SIZE SECTION 911 CIRCUIT VENTING SECTION 911 CIRCUIT VENTING |
341 | FIGURE 910.2(2) WASTE STACK VENT FIGURE 910.2(2) WASTE STACK VENT |
342 | FIGURE 910.3 WASTE STACK VENT OFFSETS AND STACK VENT CONNECTIONS FIGURE 910.3 WASTE STACK VENT OFFSETS AND STACK VENT CONNECTIONS |
343 | FIGURE 911.1 CIRCUIT VENTING FIGURE 911.1 CIRCUIT VENTING |
344 | FIGURE 911.1.1 MULTIPLE CIRCUIT-VENTED BRANCHES FIGURE 911.1.1 MULTIPLE CIRCUIT-VENTED BRANCHES FIGURE 911.2 BACK-TO-BACK WATER CLOSETS CIRCUIT VENTED FIGURE 911.2 BACK-TO-BACK WATER CLOSETS CIRCUIT VENTED |
345 | FIGURE 911.3 SIZING A CIRCUIT VENT SYSTEM FIGURE 911.3 SIZING A CIRCUIT VENT SYSTEM |
346 | FIGURE 911.3.1 SIZING MULTIPLE CIRCUIT-VENTED BRANCHES FIGURE 911.3.1 SIZING MULTIPLE CIRCUIT-VENTED BRANCHES FIGURE 911.4.1 CIRCUIT VENT WITH RELIEF VENT CONNECTION FIGURE 911.4.1 CIRCUIT VENT WITH RELIEF VENT CONNECTION |
347 | FIGURE 911.5(1) CIRCUIT-VENTED BRANCH WITH ADDITIONAL FIXTURE CONNECTIONS FIGURE 911.5(1) CIRCUIT-VENTED BRANCH WITH ADDITIONAL FIXTURE CONNECTIONS FIGURE 911.5(2) CIRCUIT-VENTED BRANCH WITH ADDITIONAL FIXTURE CONNECTIONS FIGURE 911.5(2) CIRCUIT-VENTED BRANCH WITH ADDITIONAL FIXTURE CONNECTIONS |
348 | SECTION 912 COMBINATION DRAIN AND VENT SYSTEM SECTION 912 COMBINATION DRAIN AND VENT SYSTEM FIGURE 912.2(1) COMBINATION DRAIN AND VENT FIGURE 912.2(1) COMBINATION DRAIN AND VENT |
349 | FIGURE 912.2(2) COMBINATION DRAIN AND VENT FIGURE 912.2(2) COMBINATION DRAIN AND VENT FIGURE 912.2(3) COMBINATION DRAIN AND VENT FIGURE 912.2(3) COMBINATION DRAIN AND VENT |
350 | FIGURE 912.2(4) COMBINATION DRAIN AND VENT FIGURE 912.2(4) COMBINATION DRAIN AND VENT |
351 | FIGURE 912.2(5) VERTICAL FIXTURE DRAIN COMPONENT IN COMBINATION DRAIN AND VENT SYSTEM FIGURE 912.2(5) VERTICAL FIXTURE DRAIN COMPONENT IN COMBINATION DRAIN AND VENT SYSTEM |
352 | FIGURE 912.2.2(1) COMBINATION DRAIN AND VENT FIGURE 912.2.2(1) COMBINATION DRAIN AND VENT FIGURE 912.2.2(2) COMBINATION DRAIN AND VENT FIGURE 912.2.2(2) COMBINATION DRAIN AND VENT |
353 | FIGURE 912.2.2(3) COMBINATION DRAIN AND VENT FIGURE 912.2.2(3) COMBINATION DRAIN AND VENT FIGURE 912.2.2(4) COMBINATION DRAIN AND VENT FIGURE 912.2.2(4) COMBINATION DRAIN AND VENT |
354 | FIGURE 912.2.2(5) COMBINATION DRAIN AND VENT FIGURE 912.2.2(5) COMBINATION DRAIN AND VENT TABLE 912.3 SIZE OF COMBINATION DRAIN AND VENT PIPE TABLE 912.3 SIZE OF COMBINATION DRAIN AND VENT PIPE |
355 | SECTION 913 ISLAND FIXTURE VENTING SECTION 913 ISLAND FIXTURE VENTING FIGURE 913.2 ISLAND FIXTURE VENT FIGURE 913.2 ISLAND FIXTURE VENT |
356 | SECTION 914 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS SECTION 914 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS FIGURE 914.1 RELIEF VENT CONNECTION FIGURE 914.1 RELIEF VENT CONNECTION |
357 | SECTION 915 VENTS FOR STACK OFFSETS SECTION 915 VENTS FOR STACK OFFSETS FIGURE 915.2 VENT CONNECTIONS FOR HORIZONTAL OFFSET FIGURE 915.2 VENT CONNECTIONS FOR HORIZONTAL OFFSET |
358 | SECTION 916 VENT PIPE SIZING SECTION 916 VENT PIPE SIZING TABLE 916.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS TABLE 916.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS |
359 | FIGURE 916.1(1) VENT STACK SIZING FIGURE 916.1(1) VENT STACK SIZING |
360 | FIGURE 916.1(2) VENT STACK SIZING FIGURE 916.1(2) VENT STACK SIZING FIGURE 916.1(3) STACK VENT SIZING FIGURE 916.1(3) STACK VENT SIZING |
362 | FIGURE 916.2(1) VENT SIZING FIGURE 916.2(1) VENT SIZING FIGURE 916.2(2) VENT SIZING FIGURE 916.2(2) VENT SIZING |
363 | FIGURE 916.2(3) VENT SIZING FIGURE 916.2(3) VENT SIZING |
364 | FIGURE 916.2(4) VENT SIZING FIGURE 916.2(4) VENT SIZING |
365 | FIGURE 916.3(1) DEVELOPED LENGTH OF VENTS FIGURE 916.3(1) DEVELOPED LENGTH OF VENTS |
366 | FIGURE 916.3(2) DEVELOPED LENGTH OF VENTS FIGURE 916.3(2) DEVELOPED LENGTH OF VENTS FIGURE 916.4 COMMON BRANCH VENT FIGURE 916.4 COMMON BRANCH VENT |
367 | TABLE 916.5.1 SIZE AND LENGTH OF SUMP VENTS TABLE 916.5.1 SIZE AND LENGTH OF SUMP VENTS |
368 | FIGURE 916.5.1 SUMP VENT FIGURE 916.5.1 SUMP VENT SECTION 917 AIR ADMITTANCE VALVES SECTION 917 AIR ADMITTANCE VALVES |
369 | FIGURE 917.3(1) AIR ADMITTANCE—INDIVIDUAL VENT FIGURE 917.3(1) AIR ADMITTANCE—INDIVIDUAL VENT FIGURE 917.3(2) COMMON VENT FIGURE 917.3(2) COMMON VENT FIGURE 917.3(3) WET VENT FIGURE 917.3(3) WET VENT FIGURE 917.3(4) CIRCUIT VENT FIGURE 917.3(4) CIRCUIT VENT |
370 | FIGURE 917.3(5) BRANCH VENT FIGURE 917.3(5) BRANCH VENT FIGURE 917.3(6) VENT CONNECTION NOT PERMITTED FIGURE 917.3(6) VENT CONNECTION NOT PERMITTED |
371 | FIGURE 917.3.1(1) PRESSURE IN DRAINAGE STACK FIGURE 917.3.1(1) PRESSURE IN DRAINAGE STACK FIGURE 917.3.1(2) LOCATION OF HORIZONTAL BRANCH DRAIN FIGURE 917.3.1(2) LOCATION OF HORIZONTAL BRANCH DRAIN |
372 | FIGURE 917.4 DISTANCE ABOVE DRAIN FIGURE 917.4 DISTANCE ABOVE DRAIN |
373 | FIGURE 917.7 VENT TO THE OPEN AIR REQUIRED FIGURE 917.7 VENT TO THE OPEN AIR REQUIRED |
374 | SECTION 918 ENGINEERED VENT SYSTEMS SECTION 918 ENGINEERED VENT SYSTEMS (Equation 9-1) (Equation 9-1) TABLE 918.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS ANDINDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES TABLE 918.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS ANDINDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES |
375 | FIGURE 918.2(1) INDIVIDUAL VENT DEVELOPED LENGTH FIGURE 918.2(1) INDIVIDUAL VENT DEVELOPED LENGTH |
376 | FIGURE 918.2(2) EXAMPLE OF ENGINEERED REDUCED-SIZE VENT FIGURE 918.2(2) EXAMPLE OF ENGINEERED REDUCED-SIZE VENT TABLE 918.2 MAXIMUM LOADS ON MULTIPLE-STORY DRAINAGE STACKS TABLE 918.2 MAXIMUM LOADS ON MULTIPLE-STORY DRAINAGE STACKS SECTION 919 COMPUTERIZED VENT DESIGN SECTION 919 COMPUTERIZED VENT DESIGN BIBLIOGRAPHY BIBLIOGRAPHY |
378 | CHAPTER 10: TRAPS, INTERCEPTORS AND SEPARATORS CHAPTER 10: TRAPS, INTERCEPTORS AND SEPARATORS GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION 1001 GENERAL SECTION 1001 GENERAL SECTION 1002 TRAP REQUIREMENTS SECTION 1002 TRAP REQUIREMENTS |
379 | FIGURE 1002.1(1) TRAP REQUIREMENTS FIGURE 1002.1(1) TRAP REQUIREMENTS |
380 | FIGURE 1002.1(2) TRAP REQUIREMENTS FIGURE 1002.1(2) TRAP REQUIREMENTS FIGURE 1002.2 SLIP JOINTS IN TRAPS FIGURE 1002.2 SLIP JOINTS IN TRAPS |
381 | FIGURE 1002.3 PROHIBITED TRAPS FIGURE 1002.3 PROHIBITED TRAPS |
382 | FIGURE 1002.4(1) TRAP PRIMER FOR 2 FLOOR DRAINS FIGURE 1002.4(1) TRAP PRIMER FOR 2 FLOOR DRAINS |
383 | FIGURE 1002.4(2) TRAP SUBJECT TO EVAPORATION FIGURE 1002.4(2) TRAP SUBJECT TO EVAPORATION FIGURE 1002.6 BUILDING TRAP FIGURE 1002.6 BUILDING TRAP |
384 | FIGURE 1002.7 INSTALLATION OF TRAP FIGURE 1002.7 INSTALLATION OF TRAP SECTION 1003 INTERCEPTORS AND SEPARATORS SECTION 1003 INTERCEPTORS AND SEPARATORS |
385 | FIGURE 1003.2 INTERCEPTORS AND SEPARATORS FIGURE 1003.2 INTERCEPTORS AND SEPARATORS |
386 | FIGURE 1003.3(1) TYPICAL CONCRETE GREASE INTERCEPTOR FIGURE 1003.3(1) TYPICAL CONCRETE GREASE INTERCEPTOR FIGURE 1003.3(2) TYPICAL GREASE INTERCEPTOR DESIGN FIGURE 1003.3(2) TYPICAL GREASE INTERCEPTOR DESIGN |
387 | FIGURE 1003.3.2 FOOD WASTE GRINDER CONNECTING TO GREASE INTERCEPTOR FIGURE 1003.3.2 FOOD WASTE GRINDER CONNECTING TO GREASE INTERCEPTOR |
388 | FIGURE 1003.3.4.2 FLOW CONTROL DEVICE FIGURE 1003.3.4.2 FLOW CONTROL DEVICE |
389 | TABLE 1003.3.4.1 CAPACITY OF GREASE INTERCEPTORS a TABLE 1003.3.4.1 CAPACITY OF GREASE INTERCEPTORS a |
392 | FIGURE 1003.9(1) TYPICAL SINGLE-FIXTURE INSTALLATIONS FIGURE 1003.9(1) TYPICAL SINGLE-FIXTURE INSTALLATIONS FIGURE 1003.9(2) VENTING OF GREASE INTERCEPTOR FIGURE 1003.9(2) VENTING OF GREASE INTERCEPTOR |
393 | FIGURE 1003.9(3) VENTING OF INTERCEPTORS AND SEPARATORS FIGURE 1003.9(3) VENTING OF INTERCEPTORS AND SEPARATORS |
394 | FIGURE 1003.10(1) AUTOMATIC GREASE INTERCEPTOR FIGURE 1003.10(1) AUTOMATIC GREASE INTERCEPTOR FIGURE 1003.10(2) SENSOR-CONTROLLED GREASE RECOVERY DEVICE FIGURE 1003.10(2) SENSOR-CONTROLLED GREASE RECOVERY DEVICE |
395 | FIGURE 1003.10(3) BIOREMEDIATION GREASE INTERCEPTOR FIGURE 1003.10(3) BIOREMEDIATION GREASE INTERCEPTOR SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS BIBLIOGRAPHY BIBLIOGRAPHY |
396 | CHAPTER 11: STORM DRAINAGE CHAPTER 11: STORM DRAINAGE GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION 1101 GENERAL SECTION 1101 GENERAL |
398 | TABLE 1101.7 FLOW RATE, IN GALLONS PER MINUTE, OF VARIOUS ROOF DRAINS AT VARIOUS WATER DEPTHS AT DRAIN INLETS (INCHES) TABLE 1101.7 FLOW RATE, IN GALLONS PER MINUTE, OF VARIOUS ROOF DRAINS AT VARIOUS WATER DEPTHS AT DRAIN INLETS (INCHES) FIGURE 1101.7(2) ROOF DRAIN WITH OVERFLOW FIGURE 1101.7(2) ROOF DRAIN WITH OVERFLOW |
399 | SECTION 1102 MATERIALS SECTION 1102 MATERIALS TABLE 1102.4 BUILDING STORM SEWER PIPE TABLE 1102.4 BUILDING STORM SEWER PIPE |
400 | TABLE 1102.5 SUBSOIL DRAIN PIPE TABLE 1102.5 SUBSOIL DRAIN PIPE |
401 | TABLE 1102.7 PIPE FITTINGS TABLE 1102.7 PIPE FITTINGS SECTION 1103 TRAPS SECTION 1103 TRAPS |
402 | FIGURE 1103 TRAPS ON STORM DRAINS THAT CONNECT TO COMBINATION SANITARY AND STORM SEWER SYSTEMS FIGURE 1103 TRAPS ON STORM DRAINS THAT CONNECT TO COMBINATION SANITARY AND STORM SEWER SYSTEMS SECTION 1104 CONDUCTORS AND CONNECTIONS SECTION 1104 CONDUCTORS AND CONNECTIONS SECTION 1105 ROOF DRAINS SECTION 1105 ROOF DRAINS |
403 | SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS |
404 | FIGURE 1106.1 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES FIGURE 1106.1 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES |
409 | TABLE 1106.2 SIZE OF VERTICAL CONDUCTORS AND LEADERS TABLE 1106.2 SIZE OF VERTICAL CONDUCTORS AND LEADERS TABLE 1106.3 SIZE OF HORIZONTAL STORM DRAINAGE PIPING TABLE 1106.3 SIZE OF HORIZONTAL STORM DRAINAGE PIPING |
410 | FIGURE 1106.3 HORIZONTAL DRAIN AND SEWERS FIGURE 1106.3 HORIZONTAL DRAIN AND SEWERS |
411 | FIGURE 1106.4 VERTICAL WALLS FIGURE 1106.4 VERTICAL WALLS SECTION 1107 SECONDARY (EMERGENCY) ROOF DRAINS SECTION 1107 SECONDARY (EMERGENCY) ROOF DRAINS |
412 | TABLE 1106.6 SIZE OF SEMICIRCULAR ROOF GUTTERS TABLE 1106.6 SIZE OF SEMICIRCULAR ROOF GUTTERS |
413 | FIGURE 1107.1 SECONDARY ROOF DRAINAGE NOT REQUIRED FIGURE 1107.1 SECONDARY ROOF DRAINAGE NOT REQUIRED FIGURE 1107.2(1) SEPARATE PRIMARY AND SECONDARY ROOF DRAINS FIGURE 1107.2(1) SEPARATE PRIMARY AND SECONDARY ROOF DRAINS |
414 | FIGURE 1107.2(2) PROHIBITED SECONDARY ROOF DRAIN CONNECTION FIGURE 1107.2(2) PROHIBITED SECONDARY ROOF DRAIN CONNECTION SECTION 1108 COMBINED SANITARY AND STORM SYSTEM SECTION 1108 COMBINED SANITARY AND STORM SYSTEM |
415 | FIGURE 1107.3 SIZE OF SCUPPERS FIGURE 1107.3 SIZE OF SCUPPERS |
416 | FIGURE 1108.1 COMBINED DRAIN AND SEWER FIGURE 1108.1 COMBINED DRAIN AND SEWER TABLE 1108.1 EQUIVALENT ROOF AREA CONVERSIONS TABLE 1108.1 EQUIVALENT ROOF AREA CONVERSIONS SECTION 1109 VALUES FOR CONTINUOUS FLOW SECTION 1109 VALUES FOR CONTINUOUS FLOW SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS |
417 | FIGURE 1110.4 MINIMUM NUMBER OF ROOF DRAINS FOR CONTROLLED FLOW FIGURE 1110.4 MINIMUM NUMBER OF ROOF DRAINS FOR CONTROLLED FLOW |
418 | SECTION 1111 SUBSOIL DRAINS SECTION 1111 SUBSOIL DRAINS FIGURE 1111.1(1) SUBSOIL DRAIN SUBJECT TO BACKFLOW FIGURE 1111.1(1) SUBSOIL DRAIN SUBJECT TO BACKFLOW SECTION 1112 BUILDING SUBDRAINS SECTION 1112 BUILDING SUBDRAINS |
419 | FIGURE 1111.1(2) SUBSOIL DRAINAGE FIGURE 1111.1(2) SUBSOIL DRAINAGE SECTION 1113 SUMPS AND PUMPING SYSTEMS SECTION 1113 SUMPS AND PUMPING SYSTEMS |
420 | BIBLIOGRAPHY BIBLIOGRAPHY |
422 | CHAPTER 12: SPECIAL PIPING AND STORAGE SYSTEMS CHAPTER 12: SPECIAL PIPING AND STORAGE SYSTEMS GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION 1201 GENERAL SECTION 1201 GENERAL SECTION 1202 MEDICAL GASES SECTION 1202 MEDICAL GASES |
423 | SECTION 1203 OXYGEN SYSTEMS SECTION 1203 OXYGEN SYSTEMS |
424 | BIBLIOGRAPHY BIBLIOGRAPHY |
426 | CHAPTER 13: REFERENCED STANDARDS CHAPTER 13: REFERENCED STANDARDS GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE |
427 | FIGURE 13 REFERENCED STANDARDS FIGURE 13 REFERENCED STANDARDS |
428 | ANSI ANSI ARI ARI ASME ASME |
429 | ASSE ASSE |
430 | ASTM ASTM |
433 | AWS AWS AWWA AWWA CISPI CISPI CSA CSA |
434 | ICC ICC |
435 | ISEA ISEA NFPA NFPA NSF NSF PDI PDI UL UL |
436 | APPENDIX A: PLUMBING PERMIT FEE SCHEDULE APPENDIX A: PLUMBING PERMIT FEE SCHEDULE GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE |
438 | APPENDIX B: RATES OF RAINFALL FOR VARIOUS CITIES APPENDIX B: RATES OF RAINFALL FOR VARIOUS CITIES GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE ALABAMA: ALABAMA: ALASKA: ALASKA: ARIZONA: ARIZONA: ARKANSAS: ARKANSAS: CALIFORNIA: CALIFORNIA: COLORADO: COLORADO: CONNECTICUT: CONNECTICUT: DELAWARE: DELAWARE: DISTRICT OF COLUMBIA: DISTRICT OF COLUMBIA: FLORIDA: FLORIDA: GEORGIA: GEORGIA: HAWAII: HAWAII: IDAHO: IDAHO: ILLINOIS: ILLINOIS: INDIANA: INDIANA: IOWA: IOWA: KANSAS: KANSAS: KENTUCKY: KENTUCKY: LOUISIANA: LOUISIANA: MAINE: MAINE: MARYLAND: MARYLAND: MASSACHUSETTS: MASSACHUSETTS: MICHIGAN: MICHIGAN: MINNESOTA: MINNESOTA: MISSISSIPPI: MISSISSIPPI: |
439 | MISSOURI: MISSOURI: MONTANA: MONTANA: NEBRASKA: NEBRASKA: NEVADA: NEVADA: NEW HAMPSHIRE: NEW HAMPSHIRE: NEW JERSEY: NEW JERSEY: NEW MEXICO: NEW MEXICO: NEW YORK: NEW YORK: NORTH CAROLINA: NORTH CAROLINA: NORTH DAKOTA: NORTH DAKOTA: OHIO: OHIO: OKLAHOMA: OKLAHOMA: OREGON: OREGON: PENNSYLVANIA: PENNSYLVANIA: RHODE ISLAND: RHODE ISLAND: SOUTH CAROLINA: SOUTH CAROLINA: SOUTH DAKOTA: SOUTH DAKOTA: TENNESSEE: TENNESSEE: TEXAS: TEXAS: UTAH: UTAH: VERMONT: VERMONT: VIRGINIA: VIRGINIA: WASHINGTON: WASHINGTON: WEST VIRGINIA: WEST VIRGINIA: WISCONSIN: WISCONSIN: WYOMING: WYOMING: |
440 | APPENDIX C: GRAY WATER RECYCLING SYSTEMS APPENDIX C: GRAY WATER RECYCLING SYSTEMS GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION C101 GENERAL SECTION C101 GENERAL |
442 | FIGURE 1 GRAY WATER RECYCLING SYSTEM FOR SUBSURFACE LANDSCAPE IRRIGATION FIGURE 1 GRAY WATER RECYCLING SYSTEM FOR SUBSURFACE LANDSCAPE IRRIGATION |
443 | FIGURE 2 GRAY WATER RECYCLING SYSTEM FOR FLUSHING WATER CLOSETS AND URINALS FIGURE 2 GRAY WATER RECYCLING SYSTEM FOR FLUSHING WATER CLOSETS AND URINALS |
444 | SECTION C102 SYSTEMS FOR FLUSHING WATERCLOSETS AND URINALS SECTION C102 SYSTEMS FOR FLUSHING WATERCLOSETS AND URINALS SECTION C103 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS SECTION C103 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS |
445 | TABLE C103.6 GRAY WATER DISCHARGE VOLUMES TABLE C103.6 GRAY WATER DISCHARGE VOLUMES |
447 | TABLE C103.8 LOCATION OF GRAY WATER SYSTEM TABLE C103.8 LOCATION OF GRAY WATER SYSTEM |
448 | TABLE C 103.9.1 DESIGN LOADING RATE TABLE C 103.9.1 DESIGN LOADING RATE |
449 | TABLE C103.10 DISTRIBUTION PIPE TABLE C103.10 DISTRIBUTION PIPE |
450 | APPENDIX D: DEGREE DAY AND DESIGN TEMPERATURES APPENDIX D: DEGREE DAY AND DESIGN TEMPERATURES GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE LOAD CALCULATIONS LOAD CALCULATIONS PIPING INSULATION PIPING INSULATION PROTECTION OF VENT TERMINALS PROTECTION OF VENT TERMINALS BIBLIOGRAPHY BIBLIOGRAPHY |
451 | TABLE D101 DEGREE DAY AND DESIGN TEMPERATURES a FOR CITIES IN THE UNITED STATES TABLE D101 DEGREE DAY AND DESIGN TEMPERATURES a FOR CITIES IN THE UNITED STATES |
456 | APPENDIX E: SIZING OF WATER PIPING SYSTEM APPENDIX E: SIZING OF WATER PIPING SYSTEM GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION E101 GENERAL SECTION E101 GENERAL SECTION E102 INFORMATION REQUIRED SECTION E102 INFORMATION REQUIRED |
457 | SECTION E103 SELECTION OF PIPE SIZE SECTION E103 SELECTION OF PIPE SIZE |
461 | TABLE E.1 TABLE E.1 |
462 | TABLE E.2 TABLE E.2 FIGURE 103.3(1) EXAMPLE-SIZING FIGURE 103.3(1) EXAMPLE-SIZING |
463 | TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS |
464 | TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURES a TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURES a |
465 | TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND |
466 | TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi) TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi) |
467 | TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet) TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet) TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBE a (feet) TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBE a (feet) |
468 | FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPE a (TYPE K, ASTM B 88 COPPER TUBING) FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPE a (TYPE K, ASTM B 88 COPPER TUBING) |
469 | FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPE a (TYPE L, ASTM B 88 COPPER TUBING) FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPE a (TYPE L, ASTM B 88 COPPER TUBING) |
470 | FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPE a (TYPE M, ASTM B 88 COPPER TUBING) FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPE a (TYPE M, ASTM B 88 COPPER TUBING) |
471 | FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPE a FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPE a |
472 | FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPE a FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPE a |
473 | FIGURE E103.3(7) FRICTION LOSS IN FAIRLY ROUGH PIPE a FIGURE E103.3(7) FRICTION LOSS IN FAIRLY ROUGH PIPE a |
474 | SECTION E201 SELECTION OF PIPE SIZE SECTION E201 SELECTION OF PIPE SIZE |
475 | TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.) TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.) |
478 | APPENDIX F: STRUCTURAL SAFETY APPENDIX F: STRUCTURAL SAFETY GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION F101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS SECTION F101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS |
479 | FIGURE 101.1 CUTTING, NOTCHING AND BORING JOISTS FIGURE 101.1 CUTTING, NOTCHING AND BORING JOISTS FIGURE 101.2 CUTTING, NOTCHING AND BORED HOLES FIGURE 101.2 CUTTING, NOTCHING AND BORED HOLES |
480 | APPENDIX G: VACUUM DRAINAGE SYSTEM APPENDIX G: VACUUM DRAINAGE SYSTEM GENERAL COMMENTS GENERAL COMMENTS PURPOSE PURPOSE SECTION G101 VACUUM DRAINAGE SYSTEM SECTION G101 VACUUM DRAINAGE SYSTEM |
481 | FIGURE G101.2.1(1) VACUUM SYSTEMS FIGURE G101.2.1(1) VACUUM SYSTEMS FIGURE G101.2.1(2) VACUUM SYSTEMS FIGURE G101.2.1(2) VACUUM SYSTEMS |
482 | FIGURE G101.2.2 TYPICAL WATER CLOSET FIGURE G101.2.2 TYPICAL WATER CLOSET |
484 | INDEX INDEX WELCOME PAGE WELCOME PAGE |