IEEE 1566-2005
$62.83
IEEE Standard for Performance of Adjustable Speed AC Drives Rated 375 kW and Larger
Published By | Publication Date | Number of Pages |
IEEE | 2005 |
New IEEE Standard – Superseded. This standard applies to AC adjustable speed drive (ASD) systems rated over 375 kW and above 750 V output voltage as used in petrochemical and similar applications. It covers the performance requirements for an ASD system including, but not limited to, input transformer or reactor as required, power electronics, control interfaces, cooling system, switchgear, and motor. Requirements for power quality, engineering analysis, start-up assistance, training, and spare parts are also included. Certain items such as the motor, switchgear or transformer may be excluded from the scope of vendor supply if so specified in the data sheets; however the system vendor shall specify any special requirements for the equipment thus excluded.
PDF Catalog
PDF Pages | PDF Title |
---|---|
3 | IEEE Standard for Performance of Adjustable Speed AC Drives Rated 375 kW and Larger |
6 | Introduction Notice to users Errata Interpretations Patents |
7 | Participants |
9 | CONTENTS |
13 | IEEE Standard for Performance of Adjustable Speed AC Drives Rated 375 kW and Larger 1. Overview 1.1 Scope 1.2 Purpose 1.3 Application |
14 | 2. Normative references |
15 | 3. Definitions 4. Safety 4.1 General |
16 | 4.2 ASD construction requirements |
17 | 5. Unit construction 5.1 ASD structure |
18 | 5.2 Insulation 5.3 Nameplate 5.4 Rectifier |
19 | 5.5 DC link 5.6 Inverter 5.7 Modular system |
20 | 6. Adjustable speed operation 6.1 Power supply 6.2 Harmonics 6.3 Capacity 6.4 Performance |
21 | 6.5 Grounding 6.6 Rating of supply 6.7 Transient overvoltages 6.8 Voltage sags |
22 | 6.9 Loss of voltage 6.10 Three-phase voltage swells 6.11 Voltage distortion 6.12 Voltage unbalance 6.13 Common-mode voltage 6.14 Power-factor correction capacitors—Switching transients |
23 | 6.15 Harmonic distortion 6.16 Electromagnetic interference and radio-frequency interference 6.17 Acoustic noise level 7. Control 7.1 General |
24 | 7.2 Local control 7.3 Remote control (general) |
25 | 7.4 Bypass operation |
26 | 8. Input transformer or reactor 8.1 Transformer |
27 | 8.2 Reactor 9. Motor 9.1 Specification 9.2 Temperatures |
28 | 9.3 Synchronous motor 9.4 Retrofit 10. Switchgear and starters 10.1 Requirements 10.2 Switchgear supply |
29 | 11. Cooling system 11.1 Cooling system 11.2 Air cooling 11.3 Liquid cooling |
30 | 12. System coordination 12.1 Responsibility 12.2 Compatibility 13. Engineering studies 13.1 General 13.2 Studies to determine process or driven equipment requirements 13.3 Power-system analysis to determine system response to ASD |
31 | 13.4 Studies to determine the system mechanical constraints 13.5 Studies to determine the heating or cooling constraints 13.6 Reliability analysis 14. Inspection and factory tests 14.1 Records 14.2 Test plan |
32 | 14.3 Motor tests 14.4 System test |
33 | 14.5 Testing of synchronous motor applications 15. Commissioning and startup assistance 15.1 Commissioning plan 15.2 Field service |
34 | 15.3 Results 15.4 Training 16. Spare parts 17. Data interchange |
35 | Annex A (normative) Technical data sheet (to be completed by the purchaser) |
40 | Annex B (normative) Technical data sheet (to be completed by vendor) |
44 | Annex C (informative) Engineering studies: Typical requirements (tutorial only) |
47 | Annex D (informative) Bibliography |