IEEE 2465-2023
$38.46
IEEE Trial-Use Recommended Practice for Pulse-Type Partial Discharge Measurements on Individual Stator Coils and Bars (Approved Draft)
Published By | Publication Date | Number of Pages |
IEEE | 2023 | 49 |
New IEEE Standard – Active. Pulse-type partial discharge test methods for individual form-wound stator coils and bars that are equipped with PD suppression coatings and energized with a sinusoidal voltage source are described in this recommended practice. A uniform procedure for measurements in terms of apparent charge at frequencies below 1 MHz and for measurements in millivolts at higher frequencies, up to 300 MHz is also provided in this recommended practice. This document does not provide pass/fail criteria, but it does describe the measurement circuit, the simulated slot, external factors affecting the measurements, the recommended method for calibration or normalization, appropriate test voltage levels, the need for and parameters of conditioning, and it provides guidelines for interpretation of test results.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std 2465™-2023 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
8 | Participants |
9 | Introduction |
10 | Contents |
11 | List of Figures |
13 | 1. Overview 1.1 Scope 1.2 Purpose |
14 | 1.3 Word usage 2. Normative references |
15 | 3. Definitions, acronyms, and abbreviations 3.1 Definitions |
17 | 3.2 Acronyms and abbreviations 4. Measurement circuits |
18 | 4.1 Measurement circuits—low frequency (LF) |
19 | 4.2 Measurement circuits—HF/VHF |
20 | 4.3 Near-field antennae—electromagnetic probe |
21 | 5. Simulated slot |
23 | 6. External factors affecting measurement |
24 | 7. Method for calibration or normalization 7.1 Calibration of PD pulses into charge (IEC 60270 detectors) |
25 | 7.2 Normalization for non-IEC 60270 detectors |
27 | 8. Test voltages and protection |
28 | 9. Conditioning and test procedures |
29 | 10. Interpretation of results 10.1 Magnitude and polarity of maximum PD pulses |
30 | 10.2 Integrated quantities 10.3 Pulse height and pulse phase analysis 10.4 Time-frequency classification map 10.5 Three Center-frequency relation diagram or multi-band synchronous measurements |
31 | Annex A (informative) Bibliography |
33 | Annex B (informative) HF/VHF measurement incorporating ground isolation circuit |
34 | Annex C (informative) Simulated slot clamping force |
37 | Annex D (informative) Typical PD pulse-phase patterns (examples) |
41 | Annex E (informative) Typical time-frequency classification maps for individual stator coils and bars |
46 | Annex F (informative) 3 center-frequency relation diagram (3CFRD) cluster separation example |