IEEE 515-2017
$59.58
IEEE Standard for the Testing, Design, Installation, and Maintenance of Electrical Resistance Trace Heating for Industrial Applications
Published By | Publication Date | Number of Pages |
IEEE | 2017 | 83 |
Revision Standard – Active. Specific testing requirements for qualifying electrical resistance trace heating for use in industrial applications in ordinary locations, as well as a basis for electrical and thermal design, are included in this standard.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std 515™-2017 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
7 | Participants |
8 | Introduction |
9 | Contents |
11 | 1. Overview 1.1 Scope 1.2 Purpose 2. Normative references |
12 | 3. Definitions |
15 | 4. General product testing 4.1 Type test—general purpose tests |
27 | 4.2 Type test—determination of maximum sheath temperature |
35 | 4.3 Routine tests 5. Marking and installation instructions 5.1 Product markings for trace heating devices |
36 | 5.2 Markings for field-assembled components 5.3 Installation instructions 6. Design 6.1 Process considerations |
37 | 6.2 Site considerations 6.3 Thermal insulation and heat-loss considerations |
41 | 6.4 Maximum temperature determination |
45 | 6.5 Design information |
47 | 6.6 Power system |
49 | 6.7 Special considerations |
52 | 6.8 Controlling and monitoring considerations |
55 | 6.9 Safety shower design requirements |
56 | 7. Installation 7.1 Personnel 7.2 Receiving and storage of materials |
57 | 7.3 Scheduling of installation 7.4 General installation recommendations |
59 | 7.5 Controls and sensors 7.6 Testing after installation 7.7 Thermal insulation—recommendations |
60 | 7.8 Functional check and field documentation—recommendations |
61 | 8. Maintenance 8.1 General maintenance recommendations 8.2 Visual inspection 8.3 Periodic operational check |
62 | 8.4 Record keeping |
63 | Annex A (informative) Bibliography |
65 | Annex B (informative) Pipe heat-loss considerations B.1 Heat-loss formula |
68 | B.2 Example heat loss calculations |
71 | Annex C (informative) Vessel heat-loss considerations C.1 Insulation heat loss (Qins) C.2 Slab surface areas (Qslab) |
72 | C.3 Support heat loss (Qsupt) |
73 | C.4 Manhole heat loss (Qmanhole) C.5 Convection coefficient equations |
75 | Annex D (informative) Heat-up and cool-down considerations D.1 Heat-up |
76 | D.2 Cool-down |
78 | Annex E (informative) Method to determine equivalent thicknesses of insulating cements |
79 | Annex F (informative) Design basic data—example (see 6.5) |
80 | Annex G (informative) Trace heater installation record—example (see 7.2.2) |
81 | Annex H (informative) Trace heater commissioning record—example (see 7.8) |
82 | Annex I (informative) Maintenance log record—example (see 8.4.3) |
83 | Back cover |