IEEE C37.09-2018:2021 Edition

$91.54

IEEE Standard Test Procedures for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V

Published By Publication Date Number of Pages
IEEE 2021 21
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Revision Standard – Active. The testing procedures for all high-voltage circuit breakers that include voltage ratings above 1000 V ac and comprise both indoor and outdoor types having the preferred ratings as listed in IEEE Std C37.04(TM) are covered. Typical circuit breakers covered by these standards have maximum voltage ratings from 4.76 kV through 800 kV, and continuous current ratings of 600 A through 5000 A associated with the various maximum voltage ratings. The test procedures verify all assigned ratings, including continuous current, dielectric withstand voltages, short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. Production test procedures are also included. This standard does not cover generator circuit breakers as these are covered in IEC/IEEE 62271-37-013. (Note: IEEE Std C37.09-2018 requires the use of a color monitor (and color printer) to view many of the graphics contained in this standard. Color is essential to the understanding of the graphics.)

PDF Catalog

PDF Pages PDF Title
1 IEEE Std C37.09-2018 Cor1-2021 Front cover
2 Title page
4 Important notices and disclaimers concerning IEEE standards documents
8 Participants
10 Introduction
11 Contents
12 1. Scope
13 4.5.7 Chopped wave lightning impulse withstand voltage tests
4.5.8.1 Waveform for switching impulse voltage tests
4.8.2.3.3 Arcing time for three-phase test duty T100a
16 4.8.2.3.4 Arcing time for three-phase tests covering both conditions for kpp = 1.3 and kpp = 1.5
4.8.2.7 Control voltage
17 4.8.3.4 Single-phase tests with splitting of test duties in test series taking into account associated TRV for each pole-to-clear
4.8.4.4 Test duty T100a
4.8.5.4.3 Condition check after meeting service capability tests
18 4.10.4 Grounding of the supply circuit
4.10.7 Test voltage
4.10.9 Test duties
19 4.10.9.1.3 Class C2 alternative of separate making tests
4.10.9.1.8 Three-phase line-charging and cable-charging current switching tests for class C2
4.10.9.2.7 Single-phase and three-phase capacitance current switching tests for class C1
20 4.12.4.1 Single phase
5.6.1 Controlled pressure systems for gas
5.6.2 Closed pressure systems for gas
21 Back cover
IEEE C37.09-2018
$91.54