IEEE C37.121-2020(Redline)

$51.46

IEEE Guide for Switchgear–Unit Substation–Requirements (Redline)

Published By Publication Date Number of Pages
IEEE 2020
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Revision Standard – Active. The basis for the coordination of equipment in unit substations by assisting in the selection of components is intended as the use of this guide. A variety of designs for unit substations are possible using various combinations of incoming sections, transformer sections, outgoing sections, and transition sections. It is intended that the incoming, outgoing, transformer, and transition sections included in a unit substation meet the basic requirements of applicable industry standards for those sections. This guide covers three-phase unit substations for step-down operation in the range of 112.5 kVA or greater at primary voltages of 601 V through 52 kV.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std C37.121™-2020 Front cover
2 Title page
4 Important Notices and Disclaimers Concerning IEEE Standards Documents
8 Participants
9 Introduction
10 Contents
12 1. Overview
1.1 Scope
1.2 Purpose
13 1.3 Word usage
2. Normative references
14 3. Definitions
15 4. Service conditions
4.1 General
4.2 Usual service conditions
16 4.3 Unusual service conditions
5. Transformer section
5.1 General
18 5.2 Primary unit substation transformers
5.3 Secondary unit substation transformers
19 6. Incoming section
6.1 General
6.2 High-voltage (or primary) bushings on the transformer cover
6.3 Primary terminal chamber on the transformer
6.4 Metal-enclosed bus
6.5 Metal-clad or metal-enclosed switchgear
21 6.6 Metal-enclosed interrupter switchgear
22 6.7 Cutout, fuse, or fuse link
6.8 Metal-enclosed switchgear incorporating gas insulation systems
7. Outgoing section
7.1 General
7.2 Metal-clad switchgear
23 7.3 Metal-enclosed interrupter switchgear
7.4 Metal-enclosed bus
7.5 Metal-enclosed, low-voltage, power circuit breaker switchgear
7.6 Switchboards
7.7 Motor control centers
8. Ratings
8.1 General
8.2 Rated power frequency
8.3 Rated kVA
24 8.4 Rated high voltage (or primary voltage) and rated low voltage (or secondary voltage)
8.5 Rated continuous current
8.6 Rated short-time withstand current
8.7 Rated momentary withstand current
8.8 Rated power frequency withstand voltages
25 8.9 Rated lightning impulse withstand voltage (BIL)
9. Construction
9.1 General
9.2 Phase and polarity arrangements
9.3 Phase sequence
9.4 Metal barriers
9.5 Interlocks
26 9.6 Grounding
9.7 Nameplates
9.8 Drawings, diagrams, instructions
9.9 Coordination
27 10. Typical arrangements
10.1 General
10.2 Primary unit substations
29 10.3 Secondary unit substations
32 11. Guide for selection, application, installation, and maintenance of unit substations
11.1 Application considerations
11.2 Unusual service conditions
33 11.3 System conditions
11.4 Transformer selection
34 11.5 Load requirements
11.6 Miscellaneous design considerations
36 11.7 Installation, field-testing, operation, and maintenance
38 Annex A (informative) Bibliography
40 Back cover
IEEE C37.121-2020
$51.46