IEEE C57.13.5-2019
$59.58
IEEE Standard for Performance and Test Requirements for Instrument Transformers of a Nominal System Voltage of 115 kV and Above
Published By | Publication Date | Number of Pages |
IEEE | 2019 | 81 |
Revision Standard – Active. Single-phase instrument transformers of a nominal system voltage of 115 kV and above with capacitive insulation system for line-to-ground connection and for both indoor and outdoor application are discussed in this standard. This standard is intended for use as a supplement to IEEE Std C57.13-2016 and as a basis for performance and safety of equipment. Test sequences, criteria, methods, and documentation for the test are also described.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C57.13.5™-2019 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
7 | Participants |
9 | Introduction |
10 | Contents |
12 | 1. Overview 1.1 Scope 1.2 Purpose 1.3 Word usage |
13 | 2. Normative references 3. Definitions |
15 | 4. General 4.1 Insulation requirements |
19 | 4.2 Mineral oil requirements 4.3 Requirements for accuracy and accuracy calibration systems 4.4 Mechanical performance requirements |
21 | 4.5 Thermal performance requirements 4.6 Ground shield requirements 4.7 Dissolved gas and water content requirements for new oil-immersed transformers |
22 | 4.8 Endurance capability for fast high voltage transient 4.9 Performance of internal arc protection 4.10 Identification of test sample in the type test report 4.11 Secondary short-circuit capability for voltage transformers |
23 | 4.12 Relaying current transformers having an anti-remanence gap 4.13 Gas filling pressure and gas monitoring for gas-filled instrument transformers 5. Test conditions |
24 | 6. Classification of tests 6.1 Routine tests and test sequences |
27 | 6.2 Type tests and test sequences |
30 | 6.3 Special tests 7. Routine test procedures (applicable to instrument transformers) 7.1 Verification of terminal markings and polarity 7.2 Capacitance and dissipation factor test 7.3 Applied voltage test on secondary windings |
31 | 7.4 Insulation resistance test on windings 7.5 Lightning impulse voltage test on the primary winding |
32 | 7.6 Power frequency voltage withstand test 7.7 Partial discharge test |
33 | 7.8 Dissolved gas and water content analysis for oil-immersed transformers (of a nominal system voltage of 345 kV and above) 7.9 Sealing test 7.10 Ground shield check |
34 | 7.11 Tests on the mineral oil 7.12 Inspection and routine pressure test for enclosure of gas-filled instrument transformers 8. Routine test procedures (applicable to current transformers) 8.1 Inter-turn over-voltage test |
35 | 8.2 Accuracy test for the metering rated current transformers 8.3 Resistance measurement of relaying rated secondary windings |
36 | 8.4 Performance characteristics of relaying current transformers |
37 | 9. Routine test procedures (applicable to voltage transformers) 9.1 Applied voltage test on the neutral terminal 9.2 Accuracy test 9.3 Excitation characteristics with respect to rated voltage factor |
38 | 9.4 Resistance measurement of windings 10. Type test procedures (applicable to instrument transformers) 10.1 Dissolved gas and water content analysis 10.2 Mechanical test |
39 | 10.3 Lightning impulse voltage test on the primary winding |
40 | 10.4 Switching impulse voltage test on the primary winding – wet |
41 | 10.5 External radio influence voltage (RIV) test 10.6 Power frequency voltage withstand test – wet 10.7 Power frequency voltage withstand/partial discharge test – dry |
42 | 10.8 Temperature rise test |
44 | 10.9 Short-time mechanical and thermal rating test |
45 | 10.10 Accuracy performance test 10.11 Creepage distance measurement |
46 | 10.12 Leakage test at low temperature for gas-filled instrument transformers 10.13 Burst test on enclosure for gas-filled instrument transformers 11. Type test procedure (applicable to current transformers) 11.1 Secondary open-circuit voltage withstand test |
47 | 12. Special test procedures 12.1 Endurance chopped wave test |
48 | 12.2 Internal arc test |
49 | 12.3 Seismic qualification 13. Identification of test sample in the type test report |
50 | 13.1 Document package related to transformer type |
51 | Annex A (normative) Test code A.1 Temperature rise test |
52 | A.2 Leakage test at low temperature for gas-filled instrument transformers |
53 | A.3 Endurance chopped wave test |
55 | Annex B (normative) Validity of type test reports and guidance for reviewing the design comparison report for the modified design B.1 Validity of type test reports B.2 Guidance of reviewing the comparison report |
57 | Annex C (normative) Current transformers used for the detection of unbalance current of capacitor banks C.1 General C.2 Definition C.3 General requirements |
63 | C.4 Specific requirements |
68 | Annex D (normative) Gas tightness D.1 Specification D.2 Testing D.3 Cumulative test method and calibration procedure |
72 | D.4 Time between replenishments |
73 | Annex E (informative) Dielectric tests performed at an altitude of 1000 m or less for instrument transformers designed for installation at altitudes greater than 1000 m |
74 | Annex F (informative) Dielectric tests, oil sampling, and other related measurements in the field |
75 | Annex G (informative) Internal arc protection for instrument transformers |
76 | Annex H (informative) Rated voltage factor |
77 | Annex I (informative) Current transformers having transient performance requirements |
78 | Annex J (informative) Electrical endurance test, explanatory note |
79 | Annex K (informative) Bibliography |
81 | Back cover |