IEEE ISO IEC 62271 111 2006
$107.79
IEC 62271-111 Ed.1 (IEEE Std C37.60-2003-Compilation): High Voltage Switchgear and Controlgear Part 111: Overhead, Pad-Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for alternating current systems up to 38 kV
Published By | Publication Date | Number of Pages |
IEEE | 2006 | 79 |
– Active. This Standard applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters for rated maximum voltages above 1000 V and up to 38 kV. The following is also included in section 1: In order to simplify this standard where possible, the term recloser/FI (reclosers/FIs) has been substituted for automatic circuit recloser or fault interrupter or both. NOTE–When reclosers are applied in substation, special considerations may apply.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEC 62271-111 Front Cover |
3 | Title Page |
5 | Contents |
7 | Foreword |
10 | IEEE Introduction |
11 | 1. Scope 2. References |
13 | 3. Definitions |
14 | 4. Service conditions 4.1 Usual service conditions 4.2 Unusual service conditions |
15 | 5. Rating 5.1 Rating information 5.2 Rated maximum voltage |
16 | 5.3 Rated power-frequency 5.4 Rated continuous current |
17 | 5.5 Rated minimum tripping current… 5.6 Rated symmetrical interrupting current |
19 | 5.7 Rated symmetrical making current 5.8 Rated lightning impulse withstand voltage 5.9 Rated control voltage and ranges 5.10 Rated line and cable charging interrupting currents (where applicable) |
25 | 6. Design tests (type tests) 6.1 General 6.2 Insulation (dielectric) tests |
28 | 6.3 Switching tests |
31 | 6.4 Making current capability 6.5 Rated symmetrical interrupting current tests |
42 | 6.6 Minimum tripping current tests |
43 | 6.7 Partial discharge (corona) tests |
44 | 6.8 Radio influence voltage tests (RIV) |
45 | 6.9 Surge current test; series-trip reclosers/FIs |
46 | 6.10 Temperature rise test |
48 | 6.11 Time-current tests |
49 | 6.12 Mechanical duty test 6.13 Control electronic elements surge withstand capability (SWC) tests |
51 | 6.14 Condition of recloser/FI after each test of… |
52 | 7. Production tests (routine tests) |
53 | 7.1 Reclosing and overcurrent trip calibration 7.2 Control, secondary wiring, and accessory devices check tests 7.3 Dielectric withstand test; 1-min. dry power-frequency 7.4 Partial discharge test 7.5 Mechanical operations tests |
54 | 7.6 Water leak test 8. Field tests on units in service, including dc… |
55 | 9. Construction requirements 9.1 Tank construction: submersible or dry vault reclosers/FIs 9.2 Grounding provisions |
56 | 9.3 Insulating medium quantity indicators 9.4 Oil sampling provision (submersible reclosers/FIs) 9.5 Manual operating provision 9.6 Position indicator 9.7 Nameplate markings |
57 | 9.8 Stored energy mechanism charge indicator 9.9 Enclosure integrity 9.10 Counters 9.11 Conductor terminal sizes 9.12 Tank construction-pressurized reclosers/FIs only |
58 | Annex A (informative) |
60 | Annex B (informative) |
63 | Annex C (normative) |
65 | Annex D (informative) |
69 | Annex E (informative) |
72 | Annex F (informative) |
73 | Annex G (informative) |