Infant formula and adult nutritionals — Determination of ß-carotene, lycopene and lutein by reversed-phase ultra-high performance liquid chromatography (RP-UHPLC)

Published By Publication Date Number of Pages
ISO 2020-07 38
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies a method for the quantitative determination of ß-carotene and lycopene in infant formula and adult nutritionals in solid (i.e. powders) or liquid (i.e. ready-to-feed liquids and liquid concentrates) forms using reversed-phase ultra-high performance liquid chromatography (RP-UHPLC) and UV-visible detection. The application range runs from 1 µg/100 g to 1 500 µg/100 g for lycopene and from 1 µg/100 g to 2 250 µg/100 g for ß-carotene. Based on the single-laboratory validation, the limit of detection (LOD) was 0,1 µg/100 g and the limit of quantification (LOQ) was 0,3 µg/100 g for each carotenoid.

The method does not apply to materials that contain measurable levels of ß-apo-8'-carotenal. The reproducibility data meets the requirements given in References [8] and [10].