NY StateExistingBuildingCode 2020 TEMP
$46.58
Existing Building Code of New York State
Published By | Publication Date | Number of Pages |
NY | 2020 | 322 |
This is a fully integrated custom code based on the 2018 International Existing Building Code.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover |
2 | Copyright |
3 | ACKNOWLEDGEMENTS |
5 | PREFACE |
7 | EFFECTIVE USE |
13 | TABLE OF CONTENTS |
17 | CHAPTER 1 SCOPE AND ADMINISTRATION Section 101 Title, Scope and Purpose |
18 | 102 Applicability |
19 | 103 Administration and Enforcement |
20 | 104 Materials, Equipment and Methods of Construction 105 Building Permits, Construction Inspections, Stop Work Orders, Certificates of Occupancy, and Operating Permits |
22 | 106 Submittal Documents |
23 | 107 Service Utilities 108 Inspection of Solid Fuel-burning Heating Appliances, Chimneys and Flues |
25 | CHAPTER 2 DEFINITIONS Section 201 General 202 General Definitions |
29 | CHAPTER 3 PROVISIONS FOR ALL COMPLIANCE METHODS Section 301 Administration 302 General Provisions 303 Structural Design Loads and Evaluation and Design Procedures |
30 | 304 In-Situ Load Tests 305 Accessibility for Existing Buildings |
33 | 306 Energy Storage Systems |
35 | CHAPTER 4 REPAIRS Section 401 General 402 Building Elements and Materials 403 Fire Protection 404 Means of Egress 405 Structural |
36 | 406 Electrical 407 Mechanical 408 Plumbing |
37 | CHAPTER 5 PRESCRIPTIVE COMPLIANCE METHOD Section 501 General 502 Additions |
38 | 503 Alterations |
40 | 504 Fire Escapes |
41 | 505 Windows and Emergency Escape Openings |
42 | 506 Change of Occupancy |
43 | 507 Historic Buildings |
45 | CHAPTER 6 CLASSIFICATION OF WORK Section 601 General 602 Alteration—Level 1 603 Alteration—Level 2 604 Alteration—Level 3 605 Change of Occupancy 606 Additions 607 Historic Buildings 608 Relocated Buildings |
47 | CHAPTER 7 ALTERATIONS—LEVEL 1 Section 701 General 702 Building Elements and Materials |
48 | 703 Fire Protection 704 Means of Egress 705 Reroofing |
49 | 706 Structural 707 Energy Conservation 708 Plumbing |
51 | CHAPTER 8 ALTERATIONS—LEVEL 2 Section 801 General 802 Building Elements and Materials |
53 | 803 Fire Protection |
55 | 804 Carbon Monoxide Detection 805 Means of Egress |
60 | 806 Structural |
61 | 808 Mechanical 809 Plumbing |
62 | 810 Energy Conservation |
63 | CHAPTER 9 ALTERATIONS—LEVEL 3 Section 901 General 902 Special Use and Occupancy 903 Building Elements and Materials 904 Fire Protection |
64 | 905 Means of Egress 906 Structural |
65 | 907 Energy Conservation |
67 | CHAPTER 10 CHANGE OF OCCUPANCY Section 1001 General 1002 Special Use and Occupancy 1003 Building Elements and Materials 1004 Fire Protection 1005 Means of Egress 1006 Structural |
68 | 1007 Electrical 1008 Mechanical 1009 Plumbing |
69 | 1010 Other Requirements 1011 Change of Occupancy Classification |
73 | CHAPTER 11 ADDITIONS Section 1101 General 1102 Heights and Areas 1103 Structural |
74 | 1104 Smoke Alarms in Occupancy Groups R and I-1 1105 Carbon Monoxide Detection 1106 Storm Shelters 1107 Energy Conservation |
75 | CHAPTER 12 HISTORIC BUILDINGS Section 1201 General 1202 Repairs 1203 Fire Safety |
76 | 1204 Change of Occupancy |
77 | 1205 Structural 1206 Relocated Buildings |
79 | CHAPTER 13 PERFORMANCE COMPLIANCE METHODS Section 1301 General |
91 | CHAPTER 14 RELOCATED OR MOVED BUILDINGS Section 1401 General 1402 Requirements |
93 | CHAPTER 15 CONSTRUCTION SAFEGUARDS Section 1501 General |
94 | 1502 Protection of Adjoining Property 1503 Temporary Use of Streets, Alleys and Public Property |
95 | 1504 Fire Extinguishers 1505 Means of Egress 1506 Standpipes 1507 Automatic Sprinkler System 1508 Accessibility 1509 Water Supply for Fire Protection |
97 | CHAPTER 16 REFERENCED STANDARDS |
101 | APPENDIX A GUIDELINES FOR THE SEISMIC RETROFIT OF EXISTING BUILDINGS CHAPTER A1 SEISMIC STRENGTHENING PROVISIONS FOR UNREINFORCED MASONRY BEARING WALL BUILDINGS Section A101 Purpose A102 Scope A103 Definitions |
102 | A104 Symbols and Notations A105 General Requirements |
103 | A106 Materials Requirements |
105 | A107 Quality Control A108 Design Strengths |
106 | A109 Analysis and Design Procedure A110 General Procedure A111 Special Procedure |
108 | A112 Analysis and Design |
109 | A113 Detailed Building System Design Requirements |
110 | A114 Walls of Unburned Clay, Adobe or Stone Masonry |
117 | CHAPTER A2 EARTHQUAKE HAZARD REDUCTION IN EXISTING REINFORCED CONCRETE AND REINFORCED MASONRY WALL BUILDINGS WITH FLEXIBLE DIAPHRAGMS Section A201 Purpose A202 Scope A203 Definitions A204 Symbols and Notations A205 General Requirements |
118 | A206 Analysis and Design |
119 | A207 Materials of Construction |
121 | CHAPTER A3 PRESCRIPTIVE PROVISIONS FOR SEISMIC STRENGTHENING OF CRIPPLE WALLS AND SILL PLATE ANCHORAGE OF LIGHT, WOOD-FRAME RESIDENTIAL BUILDINGS Section A301 General A302 Definitions |
122 | A303 Structural Weaknesses A304 Strengthening Requirements |
139 | CHAPTER A4 EARTHQUAKE RISK REDUCTION IN WOOD-FRAME RESIDENTIAL BUILDINGS WITH SOFT, WEAK OR OPEN FRONT WALLS Section A401 General A402 Definitions A403 Analysis and Design |
141 | A404 Prescriptive Measures for Weak Story A405 Materials of Construction |
142 | A406 Information Required to be on the Plans A407 Quality Control |
143 | CHAPTER A5 REFERENCED STANDARDS |
145 | APPENDIX B SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS FOR EXISTING BUILDINGS AND FACILITIES Section B101 Qualified Historical Buildings and Facilities B102 Fixed Transportation Facilities and Stations |
146 | B103 Dwelling Units and Sleeping Units B104 Referenced Standards |
147 | APPENDIX C GUIDELINES FOR THE WIND RETROFIT OF EXISTING BUILDINGS CHAPTER C1 GABLE END RETROFIT FOR HIGH-WIND AREAS Section C101 General C102 Definitions C103 Materials of Construction |
149 | C104 Retrofitting Gable End Walls to Enhance Wind Resistance |
169 | CHAPTER C2 ROOF DECK FASTENING FOR HIGH-WIND AREAS Section C201 General C202 Roof Deck Attachment for Wood Roofs C203 Referenced Standards |
171 | APPENDIX D DIAPER CHANGING STATIONS D101 Introduction D102 Purpose D103 Definitions |
172 | D104 General Requirements |
173 | D105 Accessibility, Construction and Installation Requirements D16 Signage D107 Maintenance D108 Historic Buildings |
189 | Resource A Table of Contents |
308 | Bibliography |
315 | INDEX |