17.240 – Radiation measurements – PDF Standards Store ?u= Wed, 06 Nov 2024 03:02:46 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 ?u=/wp-content/uploads/2024/11/cropped-icon-150x150.png 17.240 – Radiation measurements – PDF Standards Store ?u= 32 32 JIS Z 4601:2009 ?u=/product/publishers/jis/jis-z-46012009/ Wed, 06 Nov 2024 03:02:46 +0000 Radioactive Dust Samplers
Published By Publication Date Number of Pages
JIS 2009-10-20 11
]]>
This Standard specifies the radioactive dust samplers (hereafter referred to as "samplers") which can collect radioactive particles by means of filtrating in the air, which is used to obtain the radioactive concentration in air due to the particulate substances for the purpose of radiation protection in working circumstances, exhaust systems, environment, etc. of nuclear facilities, radiation utilizing facilities.

]]>
JIS Z 4520:2007 ?u=/product/publishers/jis/jis-z-45202007/ Wed, 06 Nov 2024 03:02:45 +0000 Test procedures for germanium gamma-ray detectors
Published By Publication Date Number of Pages
JIS 2007-09-20 28
]]>
Test procedures for germanium gamma-ray detectors
Published By Publication Date Number of Pages
JIS 2007-09-20 28
]]>
JIS Z 4511:2005 ?u=/product/publishers/jis/jis-z-45112005/ Wed, 06 Nov 2024 03:02:44 +0000 Methods of calibration for exposure meters, air kerma meters, air absorbed dose meters and dose-equivalent meters
Published By Publication Date Number of Pages
JIS 2005-03-20 41
]]>
Methods of calibration for exposure meters, air kerma meters, air absorbed dose meters and dose-equivalent meters
Published By Publication Date Number of Pages
JIS 2005-03-20 41
]]>
JIS Z 4511:2018 ?u=/product/publishers/jis/jis-z-45112018/ Wed, 06 Nov 2024 03:02:44 +0000 X and gamma reference radiation for calibrating dosemeters and dose rate meters and for determining their response as a function of photon energy
Published By Publication Date Number of Pages
JIS 2018-07-20 108
]]>
This Standard specifies the calibration method of dose-equivalent (rate) meter used for area monitoring and individual monitoring for radiation protection and used for setting up the air kerma reference field in the photon energy range 8 keV to 9 MeV and at air kerma rates from 10 µ Gy· h-1 to 10 Gy· h-1.

This Standard also specifies the test methods of the response as a function of photon energy and angle of radiation incidence.

This Standard is also applicable to an air absorbed dose (rate) meter, an air kerma (rate) meter and an exposure (rate) meter.

NOTE The International Standards corresponding to this Standard and the symbol of degree of correspondence are as follows.

ISO 4037-1: 1996 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy-Part 1: Radiation characteristics and production methods

ISO 4037-2: 1997 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy-Part 2: Dosimetry for radiation protection over the energy ranges from 8 ke V to 1,3 Me V and 4 Me V to 9 Me V

ISO 4037-3: 1999 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy-Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence

ISO 4037-4: 2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy-Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields (overall evaluation: MOD)

In addition, symbols which denote the degree of correspondence in the contents between the relevant International Standards and JIS are IDT (identical), MOD (modified), and NEQ (not equivalent) according to ISO/IEC Guide 21-1.

]]>
JIS Z 4501:2011 ?u=/product/publishers/jis/jis-z-45012011/ Wed, 06 Nov 2024 03:02:41 +0000 Testing method of lead equivalent for X-ray protective devices
Published By Publication Date Number of Pages
JIS 2011-03-22 9
]]>
This Standard specifies the testing method for the lead equivalent of protective devices, protective materials, etc. against X-ray tube voltages of 10 kV or over up to and including 400 kV.

]]>
JIS Z 4342:2013 ?u=/product/publishers/jis/jis-z-43422013/ Wed, 06 Nov 2024 03:02:40 +0000 Equipment for measuring specific activity of gamma-emitting radionuclides in foodstuffs
Published By Publication Date Number of Pages
JIS 2013-03-21 39
]]>
This Standard specifies the scintillation type radiation meters used for measuring the activity concentration of gamma-emitting radionuclides in food/foodstuffs (hereafter referred to as "radiation meters") under field conditions where radioactive substances have spread due to the nuclear reactor accident, etc.

It does not apply to the low background stationary radioactivity analysis equipment such as a germanium gamma -ray detector used in specialized agencies for analysis.

In addition, this Standard is applicable also to the measurement of environmental samples in general such as soil, sewage, plant and animal life.

NOTE 1 The pretreatment method of samples is not covered by this Standard.

NOTE 2 The International Standard corresponding to this Standard and the symbol of degree of correspondence are as follows.

lEC 61563 : 2001 Radiation protection instrumentation – Equipment for measuring specific activity of gamma-emitting radionuclides in foodstuffs (MOD)

In addition, symbols which denote the degree of correspondence in the contents between the relevant International Standard and JIS are IDT (identical), MOD (modified), and NEQ (not equivalent) according to ISO/IEC Guide 21-1.

]]>
JIS Z 4337:2011 ?u=/product/publishers/jis/jis-z-43372011/ Wed, 06 Nov 2024 03:02:40 +0000 Installed articles surface contamination monitoring assemblies for beta emitters
Published By Publication Date Number of Pages
JIS 2011-11-21 21
]]>
This Japanese Industrial Standard specifies the installed articles surface contamination monitoring assemblies for beta emitters (hereafter referred to as the "monitor") intended for detecting the contamination by the nuclide to emit beta rays of 0.15 MeV or over in the maximum energy for measuring the surface contamination of articles carried out from the controlled area of nuclear facility and the like.

]]>
JIS Z 4501:1988 ?u=/product/publishers/jis/jis-z-45011988/ Wed, 06 Nov 2024 03:02:40 +0000 Testing Method of Lead Equivalent for X-Ray Protective Devices
Published By Publication Date Number of Pages
JIS 1988-11-01 6
]]>
Testing Method of Lead Equivalent for X-Ray Protective Devices
Published By Publication Date Number of Pages
JIS 1988-11-01 6
]]>
JIS Z 4332:1992 ?u=/product/publishers/jis/jis-z-43321992/ Wed, 06 Nov 2024 03:02:38 +0000 General Requirements for Personal X-Ray and Gamma-Ray Dosemeters
Published By Publication Date Number of Pages
JIS 1992-03-01 12
]]>
General Requirements for Personal X-Ray and Gamma-Ray Dosemeters
Published By Publication Date Number of Pages
JIS 1992-03-01 12
]]>
JIS Z 4333:1990 ?u=/product/publishers/jis/jis-z-43331990/ Wed, 06 Nov 2024 03:02:38 +0000 Portable Photon Ambient Dose Equivalent Ratemeters for Radiation Protection
Published By Publication Date Number of Pages
JIS 1990-01-01 17
]]>
Portable Photon Ambient Dose Equivalent Ratemeters for Radiation Protection
Published By Publication Date Number of Pages
JIS 1990-01-01 17
]]>