27.080 – Heat pumps – PDF Standards Store ?u= Wed, 06 Nov 2024 01:27:40 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 ?u=/wp-content/uploads/2024/11/cropped-icon-150x150.png 27.080 – Heat pumps – PDF Standards Store ?u= 32 32 ISO/TS 16491:2012 ?u=/product/publishers/iso/iso-ts-164912012/ Wed, 06 Nov 2024 01:27:40 +0000 Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests
Published By Publication Date Number of Pages
ISO 2012-12 36
]]>
ISO/TS 16491:2012 gives guidance on the practical applications of the principles of performance measurement of air-cooled air-conditioners and air-to-air heat pumps as described in ISO 5151, ISO 13253, and ISO 15042.

]]>
ISO 5151:2017 ?u=/product/publishers/iso/iso-51512017/ Tue, 05 Nov 2024 23:27:23 +0000 Non-ducted air conditioners and heat pumps — Testing and rating for performance
Published By Publication Date Number of Pages
ISO 2017-07 82
]]>
ISO 5151:2017 specifies performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled air conditioners and air-to-air heat pumps.

ISO 5151:2017 is applicable to the following equipment:

– non-ducted air-cooled air conditioners and non-ducted air-to-air heat pumps; or

– ducted air conditioners and/or ducted heat pumps rated at less than 8 kW and intended to operate at an external static pressure of less than 25 Pa.

ISO 5151:2017 is limited to:

– residential, commercial and industrial single-package and split-system air conditioners and heat pumps;

– factory-made, electrically driven and use mechanical compression;

– utilizing single, multiple and variable capacity components;

– multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller.

The requirements of testing and rating contained in this document are based on the use of matched assemblies.

ISO 5151:2017 is not applicable to the rating and testing of the following:

a) water-source heat pumps or water cooled air conditioners;

b) multi-split-system air conditioners and air-to-air heat pumps (follow ISO 15042 for the testing of such equipment);

c) mobile (windowless) units having a condenser exhaust duct;

d) individual assemblies not constituting a complete refrigeration system;

e) equipment using the absorption refrigeration cycle;

f) ducted equipment except for those specified in this clause (follow ISO 13253 for the testing of such equipment).

ISO 5151:2017 does not cover the determination of seasonal efficiencies, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.

NOTE Throughout this document, the terms "equipment" and "systems" mean "air conditioners" and/or "heat pumps".

]]>
ISO 5151:2010 ?u=/product/publishers/iso/iso-51512010/ Tue, 05 Nov 2024 23:27:21 +0000 Non-ducted air conditioners and heat pumps — Testing and rating for performance
Published By Publication Date Number of Pages
ISO 2010-06 80
]]>
ISO 5151:2010 specifies the standard conditions for capacity and efficiency ratings of non-ducted air-cooled air conditioners and non-ducted air to air heat pumps. It is applicable to ducted units rated at less than 8 kW and intended to operate at an external static pressure of less than 25 Pa. ISO 5151:2010 also specifies the test methods for determining the capacity and efficiency ratings.

]]>
ISO 5149-3:2014 ?u=/product/publishers/iso/iso-5149-32014/ Tue, 05 Nov 2024 23:27:20 +0000 Systèmes frigorifiques et pompes à chaleur — Exigences de sécurité et d'environnement — Partie 3: Site d'installation
Published By Publication Date Number of Pages
ISO 2014-04 22
]]>
L'ISO 5149-3:2014 est applicable aux sites d'installation (espace du bâtiment et services).Elle spécifie les exigences pour le site relatives à la sécurité, qui peuvent être nécessaires en raison du système frigorifique et ses composants auxiliaires sans être directement liées à ceux-ci.

L'ISO 5149-3:2014 s'applique aux systèmes frigorifiques neufs, aux extensions ou modifications de systèmes existants et, pour les systèmes utilisés, aux systèmes transférés et exploités sur un autre site. Elle s'applique également en cas de transformation d'un système pour un autre fluide frigorigène.

]]>
ISO 5149-4:2014 ?u=/product/publishers/iso/iso-5149-42014/ Tue, 05 Nov 2024 23:27:19 +0000 Refrigerating systems and heat pumps — Safety and environmental requirements — Part 4: Operation, maintenance, repair and recovery
Published By Publication Date Number of Pages
ISO 2014-04 28
]]>
ISO 5149-4:2014 specifies requirements for safety and environmental aspects in relation to operation, maintenance and repair of refrigerating systems and the recovery, reuse and disposal of all types of refrigerant, refrigerant oil, heat transfer fluid, refrigerating system and part thereof.

These requirements are intended to minimize risks of injury to persons and damage to property and the environment resulting from improper handling of the refrigerants or from contaminants leading to system breakdown and resultant emission of the refrigerant.

]]>
ISO 5149-2:2014 ?u=/product/publishers/iso/iso-5149-22014/ Tue, 05 Nov 2024 23:27:19 +0000 Refrigerating systems and heat pumps — Safety and environmental requirements — Part 2: Design, construction, testing, marking and documentation
Published By Publication Date Number of Pages
ISO 2014-04 62
]]>
ISO 5149-2:2014 is applicable to the design, construction, and installation of refrigerating systems, including piping, components, materials, and ancillary equipment directly associated with such systems, which are not covered in ISO 5149-1, ISO 5149-3, or ISO 5149-4. It also specifies requirements for testing, commissioning, marking, and documentation. Requirements for secondary heat-transfer circuits are excluded except for any safety devices associated with the refrigerating system.

ISO 5149-2:2014 is applicable to new refrigerating systems, extensions or modifications of already existing systems, and for used systems, being transferred to and operated on another site.

ISO 5149-2:2014 applies to: a) refrigerating systems, stationary or mobile, of all sizes including heat pumps; b) secondary cooling or heating systems; c) the location of the refrigerating systems; and d)replaced parts and added components after the adoption of this part of ISO 5149, if they are not identical in function and in capacity.

ISO 5149-2:2014 does not cover "motor vehicle air conditioners". It does not apply to goods in storage, with respect to spoilage or contamination, but it also applies in the case of the conversion of a system for another refrigerant.

]]>
ISO 5149-1:2014 ?u=/product/publishers/iso/iso-5149-12014/ Tue, 05 Nov 2024 23:27:18 +0000 Refrigerating systems and heat pumps — Safety and environmental requirements — Part 1: Definitions, classification and selection criteria
Published By Publication Date Number of Pages
ISO 2014-04 52
]]>
ISO 5149-1:2014 specifies the requirements for the safety of persons and property, provides guidance for the protection of the environment, and establishes procedures for the operation, maintenance, and repair of refrigerating systems and the recovery of refrigerants.

ISO 5149-1:2014 specifies the classification and selection criteria applicable to the refrigerating systems and heat pumps. These classification and selection criteria are used in ISO 5149-2, ISO 5149-3, and ISO 5149-4.

ISO 5149-1:2014 applies to: a) refrigerating systems, stationary or mobile, of all sizes including heat pumps; b) secondary cooling or heating systems; c) the location of the refrigerating systems; and d) replaced parts and added components after adoption of this part of ISO 5149 if they are not identical in function and in the capacity.

ISO 5149-1:2014 applies to fixed or mobile systems, except to vehicle air conditioning systems covered by a specific product standard, e.g. ISO 13043 and SAE J 639.

ISO 5149-1:2014 is applicable to new refrigerating systems, extensions or modifications of already existing systems, and for used systems, being transferred to and operated on another site.

ISO 5149-1:2014 also applies in the case of the conversion of a system to another refrigerant.

Systems containing refrigerants which are not listed in ISO 817 are not covered in ISO 5149-1:2014.

]]>
ISO 5149-1:2014/Amd 1:2015 ?u=/product/publishers/iso/iso-5149-12014-amd-12015/ Tue, 05 Nov 2024 23:27:18 +0000 Refrigerating systems and heat pumps — Safety and environmental requirements — Part 1: Definitions, classification and selection criteria — Amendment 1: Correction of QLAV, QLMV
Published By Publication Date Number of Pages
ISO 2015-10 8
]]>
Refrigerating systems and heat pumps — Safety and environmental requirements — Part 1: Definitions, classification and selection criteria — Amendment 1: Correction of QLAV, QLMV
Published By Publication Date Number of Pages
ISO 2015-10 8
]]>
ISO 21978:2021 ?u=/product/publishers/iso/iso-219782021/ Tue, 05 Nov 2024 22:32:27 +0000 Heat pump water heater — Testing and rating at part load conditions and calculation of seasonal coefficient of performance for space heating
Published By Publication Date Number of Pages
ISO 2021-02 54
]]>
The document specifies test conditions for determining the seasonal performance characteristics of air source heat pump water heaters for space heating with electrically driven compressors with or without supplementary heater. The purpose of this document is to rate performance of the heat pump water heaters for space heating with no operation of any supplementary heater. In the case of heat pump water heaters for space heating consisting of several parts with refrigerant or water connections, this document applies only to those designed and supplied as a complete package.

The seasonal coefficient of performance depends, inter alia, on the climate conditions and temperature regime of the space heating distribution network.

This document defines:

— three design conditions, each of them being characterized by a design temperature which represents the lowest temperature that can occur in that design condition;

— three water temperature distribution regimes, namely "temperature application" in the text.

The user of this document is free to determine the seasonal coefficient of performance for one or more of the defined design conditions and for one or more of the defined temperature applications.

This document also provides a full description of three heating seasons that can be used with the associated design conditions.

]]>
ISO 21922:2021 ?u=/product/publishers/iso/iso-219222021/ Tue, 05 Nov 2024 22:31:53 +0000 Refrigerating systems and heat pumps — Valves — Requirements, testing and marking
Published By Publication Date Number of Pages
ISO 2021-08 98
]]>
This document specifies safety requirements, certain functional requirements, and marking of valves and other components with similar bodies, hereinafter called valves, for use in refrigerating systems including heat pumps.

This document includes requirements for valves with extension pipes.

This document describes the procedure to be followed when designing valve parts subjected to pressure as well as the criteria to be used in the selection of materials.

This document describes methods by which reduced impact values at low temperatures may be taken into account in a safe manner.

This document applies to the design of bodies and bonnets for pressure relief devices, including bursting disc devices, with respect to pressure containment but it does not apply to any other aspects of the design or application of pressure relief devices.

In addition, this document is applicable to valves with a maximum operating temperature not exceeding 200 °C and a maximum allowable pressure not exceeding 160 bar[1].

 

[1] 1 bar = 0,1 MPa.

]]>