{"id":110437,"date":"2024-10-18T15:54:04","date_gmt":"2024-10-18T15:54:04","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ca-buildingcode-vol1-2013\/"},"modified":"2024-10-24T21:57:21","modified_gmt":"2024-10-24T21:57:21","slug":"ca-buildingcode-vol1-2013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ca\/ca-buildingcode-vol1-2013\/","title":{"rendered":"CA BuildingCode vol1 2013"},"content":{"rendered":"

The California Building Code (CBC) contains general building design and construction requirements relating to fire and life safety, structural safety, and access compliance. CBC provisions provide minimum standards to safeguard life or limb, health, property, and public welfare by regulating and controlling the design, construction, quality of materials, use and occupancy, location, and maintenance of all buildings and structures and certain equipment. Matrix Adoption tables are provided at beginning of every chapter in Part 2 to indicate which chapters and sections are adopted by state agencies (for application to their respective occupancies). This 2-volume set is a fully integrated code based on the 2012 International Building Code\u00ae. The CBC includes: Title 24, Part 8 California Historical Building Code (CHBC): contains regulations of the State Historical Building Safety Board. Provisions contained in the CHBC provide for the preservation, restoration, rehabilitation, relocation, or reconstruction of buildings or structures designated as qualified historical buildings or properties. The CHBC contains alternative solutions for the preservation of qualified historical buildings or properties, to provide access for persons with disabilities, to provide a cost-effective approach to preservation, and to provide for the reasonable safety of the occupants or users. Title 24, Part 10 California Building Standards Commission (CBSC): adopts certain provisions of the International Existing Building Code, Appendix Chapter A1, Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n2013 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2, VOLUME 1 OF 2 <\/td>\n<\/tr>\n
2<\/td>\n2013 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2, VOLUME 1 OF 2 BASED ON THE 2012 INTERNATIONAL BUILDING CODE\u00ae TITLE PAGE <\/td>\n<\/tr>\n
3<\/td>\nCOPYRIGHT <\/td>\n<\/tr>\n
4<\/td>\nPREFACE
ACKNOWLEDGEMENTS <\/td>\n<\/tr>\n
5<\/td>\nCALIFORNIA CODE OF REGULATIONS, TITLE 24 CALIFORNIA AGENCY INFORMATION CONTACT LIST <\/td>\n<\/tr>\n
6<\/td>\nMARGINAL MARKINGS <\/td>\n<\/tr>\n
8<\/td>\nEFFECTIVE USE OF THE IBC\/CBC <\/td>\n<\/tr>\n
18<\/td>\nHOW TO DISTINGUISH BETWEEN MODEL CODE LANGUAGE AND CALIFORNIA AMENDMENTS <\/td>\n<\/tr>\n
20<\/td>\nCALIFORNIA MATRIX ADOPTION TABLES <\/td>\n<\/tr>\n
22<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
36<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 1 \u2013 ADMINISTRATION <\/td>\n<\/tr>\n
37<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 1 \u2013 ADMINISTRATION\u2014continued <\/td>\n<\/tr>\n
38<\/td>\nCHAPTER 1 SCOPE AND ADMINISTRATION
DIVISION I CALIFORNIA ADMINISTRATION
SECTION 1.1 GENERAL <\/td>\n<\/tr>\n
40<\/td>\nSECTION 1.2 BUILDING STANDARDS COMMISSION <\/td>\n<\/tr>\n
41<\/td>\nSECTION 1.3 BOARD OF STATE AND COMMUNITY CORRECTIONS
SECTION 1.4 DEPARTMENT OF CONSUMER AFFAIRS <\/td>\n<\/tr>\n
42<\/td>\nSECTION 1.5 RESERVED
SECTION 1.6 DEPARTMENT OF FOOD AND AGRICULTURE
SECTION 1.7 CALIFORNIA DEPARTMENT OF PUBLIC HEALTH
SECTION 1.8 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT <\/td>\n<\/tr>\n
43<\/td>\nSECTION 1.8.2 AUTHORITY AND ABBREVIATIONS <\/td>\n<\/tr>\n
44<\/td>\nSECTION 1.8.3 LOCAL ENFORCING AGENCY
SECTION 1.8.4 PERMITS, FEES, APPLICATIONS AND INSPECTIONS <\/td>\n<\/tr>\n
45<\/td>\nSECTION 1.8.5 RIGHT OF ENTRY FOR ENFORCEMENT
SECTION 1.8.6 LOCAL MODIFICATION BY ORDINANCE OR REGULATION <\/td>\n<\/tr>\n
46<\/td>\nSECTION 1.8.7 ALTERNATE MATERIALS, DESIGNS, TESTS AND METHODS OF CONSTRUCTION
SECTION 1.8.8 APPEALS BOARD <\/td>\n<\/tr>\n
47<\/td>\nSECTION 1.8.9 UNSAFE BUILDINGS OR STRUCTURES <\/td>\n<\/tr>\n
48<\/td>\nSECTION 1.8.10 OTHER BUILDING REGULATIONS
SECTION 1.9 DIVISION OF THE STATE ARCHITECT <\/td>\n<\/tr>\n
50<\/td>\nSECTION 1.10 OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT <\/td>\n<\/tr>\n
52<\/td>\nSECTION 1.11 OFFICE OF THE STATE FIRE MARSHAL <\/td>\n<\/tr>\n
56<\/td>\nSECTION 1.12 STATE LIBRARIAN
SECTION 1.13 RESERVED
SECTION 1.14 CALIFORNIA STATE LANDS COMMISSION <\/td>\n<\/tr>\n
58<\/td>\nDIVISION II SCOPE AND ADMINISTRATION
PART 1\u2014SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY <\/td>\n<\/tr>\n
59<\/td>\nPART 2\u2014ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL <\/td>\n<\/tr>\n
61<\/td>\nSECTION 105 PERMITS <\/td>\n<\/tr>\n
63<\/td>\nSECTION 106 FLOOR AND ROOF DESIGN LOADS
SECTION 107 SUBMITTAL DOCUMENTS <\/td>\n<\/tr>\n
64<\/td>\nSECTION 108 TEMPORARY STRUCTURES AND USES <\/td>\n<\/tr>\n
65<\/td>\nSECTION 109 FEES
SECTION 110 INSPECTIONS <\/td>\n<\/tr>\n
66<\/td>\nSECTION 111 CERTIFICATE OF OCCUPANCY
SECTION 112 SERVICE UTILITIES <\/td>\n<\/tr>\n
67<\/td>\nSECTION 113 BOARD OF APPEALS
SECTION 114 VIOLATIONS
SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT <\/td>\n<\/tr>\n
70<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 2 \u2013 DEFINITIONS <\/td>\n<\/tr>\n
71<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 2 \u2013 DEFINITIONS\u2014continued <\/td>\n<\/tr>\n
72<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 2 \u2013 DEFINITIONS\u2014continued <\/td>\n<\/tr>\n
73<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 2 \u2013 DEFINITIONS\u2014continued <\/td>\n<\/tr>\n
74<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 2 \u2013 DEFINITIONS\u2014continued <\/td>\n<\/tr>\n
75<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 2 \u2013 DEFINITIONS\u2014continued <\/td>\n<\/tr>\n
76<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 2 \u2013 DEFINITIONS\u2014continued <\/td>\n<\/tr>\n
77<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 2 \u2013 DEFINITIONS\u2014continued <\/td>\n<\/tr>\n
78<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 2 \u2013 DEFINITIONS\u2014continued <\/td>\n<\/tr>\n
79<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 2 \u2013 DEFINITIONS\u2014continued <\/td>\n<\/tr>\n
80<\/td>\nCHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS <\/td>\n<\/tr>\n
124<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 3 \u2013 USE AND OCCUPANCY CLASSIFICATION <\/td>\n<\/tr>\n
125<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 3 \u2013 USE AND OCCUPANCY CLASSIFICATION\u2014continued <\/td>\n<\/tr>\n
126<\/td>\nCHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
SECTION 301 GENERAL
SECTION 302 CLASSIFICATION
SECTION 303 ASSEMBLY GROUP A <\/td>\n<\/tr>\n
127<\/td>\nSECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
SECTION 306 FACTORY GROUP F <\/td>\n<\/tr>\n
128<\/td>\nSECTION 307 HIGH-HAZARD GROUP H <\/td>\n<\/tr>\n
130<\/td>\n[F] TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD <\/td>\n<\/tr>\n
131<\/td>\n[F] TABLE 307.1(1)\u2014(continued) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD <\/td>\n<\/tr>\n
132<\/td>\n[F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD <\/td>\n<\/tr>\n
133<\/td>\nSECTION 308 INSTITUTIONAL GROUP I <\/td>\n<\/tr>\n
134<\/td>\nSECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R <\/td>\n<\/tr>\n
136<\/td>\nSECTION 311 STORAGE GROUP S <\/td>\n<\/tr>\n
137<\/td>\nSECTION 312 UTILITY AND MISCELLANEOUS GROUP U
SECTION 313 LABORATORIES GROUP L [SFM] <\/td>\n<\/tr>\n
138<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 4 \u2013 SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY <\/td>\n<\/tr>\n
139<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 4 \u2013 SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY\u2014continued <\/td>\n<\/tr>\n
140<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 4 \u2013 SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY\u2014continued <\/td>\n<\/tr>\n
141<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 4 \u2013 SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY\u2014continued <\/td>\n<\/tr>\n
142<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 4 \u2013 SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY\u2014continued <\/td>\n<\/tr>\n
144<\/td>\nCHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS <\/td>\n<\/tr>\n
148<\/td>\nSECTION 403 HIGH-RISE BUILDINGS AND GROUP I-2 OCCUPANCIES HAVING OCCUPIED FLOORS LOCATED MORE THAN 75 FEET ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS <\/td>\n<\/tr>\n
149<\/td>\nTABLE 403.2.4 MINIMUM BOND STRENGTH <\/td>\n<\/tr>\n
151<\/td>\nSECTION 404 ATRIUMS
SECTION 405 UNDERGROUND BUILDINGS <\/td>\n<\/tr>\n
153<\/td>\nSECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES <\/td>\n<\/tr>\n
154<\/td>\nTABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT <\/td>\n<\/tr>\n
157<\/td>\nSECTION 407 GROUP I-2 <\/td>\n<\/tr>\n
160<\/td>\nSECTION 408 GROUP I-3 <\/td>\n<\/tr>\n
165<\/td>\nSECTION 409 MOTION PICTURE PROJECTION ROOMS <\/td>\n<\/tr>\n
166<\/td>\nSECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS <\/td>\n<\/tr>\n
168<\/td>\nSECTION 411 SPECIAL AMUSEMENT BUILDINGS
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.3.1 HEIGHT AND AREA LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS <\/td>\n<\/tr>\n
170<\/td>\n[F] TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTS <\/td>\n<\/tr>\n
171<\/td>\nSECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS <\/td>\n<\/tr>\n
172<\/td>\n[F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS <\/td>\n<\/tr>\n
173<\/td>\n[F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDSd,e,f <\/td>\n<\/tr>\n
174<\/td>\n[F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREAa
SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5 <\/td>\n<\/tr>\n
175<\/td>\n[F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTSa <\/td>\n<\/tr>\n
177<\/td>\n[F] TABLE 415.5.2 DETACHED BUILDING REQUIRED <\/td>\n<\/tr>\n
180<\/td>\n[F] TABLE 415.10.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a <\/td>\n<\/tr>\n
185<\/td>\nSECTION 416 APPLICATION OF FLAMMABLE FINISHES <\/td>\n<\/tr>\n
186<\/td>\nSECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
SECTION 419 LIVE\/WORK UNITS <\/td>\n<\/tr>\n
187<\/td>\nSECTION 420 GROUPS R-1, R-2, R-2.1, R-3, R3.1 and R-4 <\/td>\n<\/tr>\n
190<\/td>\nSECTION 421 HYDROGEN CUTOFF ROOMS
SECTION 422 AMBULATORY CARE FACILITIES <\/td>\n<\/tr>\n
191<\/td>\nSECTION 423 STORM SHELTERS
SECTION 424 CHILDREN\u2019S PLAY STRUCTURES
SECTION 425 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-2.1, R-3.1, R-4 [SFM] <\/td>\n<\/tr>\n
194<\/td>\nSECTION 426 GROUP I-4 [SFM] <\/td>\n<\/tr>\n
195<\/td>\nSECTION 427 RESERVED
SECTION 428 RESERVED
SECTION 429 RESERVED
SECTION 430 HORSE RACING STABLES [SFM]
SECTION 431 PET KENNELS [SFM]
SECTION 432 COMBUSTION ENGINES AND GAS TURBINES [SFM] <\/td>\n<\/tr>\n
196<\/td>\nSECTION 433 FIXED GUIDEWAY TRANSIT SYSTEMS [SFM] <\/td>\n<\/tr>\n
199<\/td>\nSECTION 434 EXPLOSIVES [SFM] <\/td>\n<\/tr>\n
202<\/td>\nSECTION 435 RESERVED
SECTION 436 WINERY CAVES [SFM] <\/td>\n<\/tr>\n
203<\/td>\nSECTION 437 RESERVED
SECTION 438 RESERVED
SECTION 439 PUBLIC LIBRARIES [SL AND SFM] <\/td>\n<\/tr>\n
204<\/td>\nSECTION 440 GROUP C [SFM] <\/td>\n<\/tr>\n
206<\/td>\nSECTION 441 RESERVED
SECTION 442 SCHOOL FACILITIES FOR KINDERGARTEN THROUGH 12TH GRADE AND GROUP E DAY CARE <\/td>\n<\/tr>\n
207<\/td>\nSECTION 443 GROUP L [SFM] <\/td>\n<\/tr>\n
210<\/td>\nTABLE 443.7.3.1 HAZARDOUS MATERIALS QUANTITY PER LABORATORY SUITE
SECTION 444 RESERVED
SECTION 445 LARGE FAMILY DAY-CARE HOMES [SFM] <\/td>\n<\/tr>\n
212<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 5 \u2013 GENERAL BUILDING HEIGHTS AND AREAS <\/td>\n<\/tr>\n
214<\/td>\nCHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS <\/td>\n<\/tr>\n
215<\/td>\nTABLE 503 ALLOWABLE BUILDING HEIGHTS AND AREASa, b Building height limitations shown in feet above grade plane. Story limitations shown as stories above grade plane. Building area limitations shown in square feet, as determined by the definition of \u201cArea, building,\u201d\u009d per story <\/td>\n<\/tr>\n
216<\/td>\nTABLE 503\u2014continued ALLOWABLE BUILDING HEIGHTS AND AREASa, b
FIGURE 5-1 <\/td>\n<\/tr>\n
217<\/td>\nSECTION 504 BUILDING HEIGHT
SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS <\/td>\n<\/tr>\n
218<\/td>\nSECTION 506 BUILDING AREA MODIFICATIONS
EQUATION 5-1
EQUATION 5-2
EQUATION 5-3 <\/td>\n<\/tr>\n
220<\/td>\nSECTION 507 UNLIMITED AREA BUILDINGS <\/td>\n<\/tr>\n
221<\/td>\nSECTION 508 MIXED USE AND OCCUPANCY <\/td>\n<\/tr>\n
222<\/td>\nSECTION 509 INCIDENTAL USES <\/td>\n<\/tr>\n
223<\/td>\nTABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
SECTION 510 SPECIAL PROVISIONS <\/td>\n<\/tr>\n
224<\/td>\nTABLE 509 INCIDENTAL USES <\/td>\n<\/tr>\n
228<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 6 \u2013 TYPES OF CONSTRUCTION <\/td>\n<\/tr>\n
230<\/td>\nCHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION <\/td>\n<\/tr>\n
231<\/td>\nTABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCEa, e
TABLE 602.4 WOOD MEMBER SIZE EQUIVALENCIES <\/td>\n<\/tr>\n
232<\/td>\nSECTION 603 COMBUSTIBLE MATERIAL IN TYPE I AND II CONSTRUCTION <\/td>\n<\/tr>\n
234<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 7 \u2013 FIRE AND SMOKE PROTECTION FEATURES <\/td>\n<\/tr>\n
236<\/td>\nCHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS <\/td>\n<\/tr>\n
237<\/td>\nSECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS <\/td>\n<\/tr>\n
239<\/td>\nSECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION <\/td>\n<\/tr>\n
240<\/td>\nFIGURE 705.7 EQUIVALENT OPENING FACTOR
EQUATION 7-1 <\/td>\n<\/tr>\n
241<\/td>\nTABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION <\/td>\n<\/tr>\n
242<\/td>\nEQUATION 7-2 <\/td>\n<\/tr>\n
243<\/td>\nSECTION 706 FIRE WALLS <\/td>\n<\/tr>\n
244<\/td>\nTABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS <\/td>\n<\/tr>\n
245<\/td>\nSECTION 707 FIRE BARRIERS <\/td>\n<\/tr>\n
246<\/td>\nTABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS <\/td>\n<\/tr>\n
247<\/td>\nSECTION 708 FIRE PARTITIONS <\/td>\n<\/tr>\n
248<\/td>\nSECTION 709 SMOKE BARRIERS
SECTION 710 SMOKE PARTITIONS <\/td>\n<\/tr>\n
249<\/td>\nSECTION 711 HORIZONTAL ASSEMBLIES <\/td>\n<\/tr>\n
250<\/td>\nSECTION 712 VERTICAL OPENINGS <\/td>\n<\/tr>\n
251<\/td>\nSECTION 713 SHAFT ENCLOSURES <\/td>\n<\/tr>\n
253<\/td>\nSECTION 714 PENETRATIONS <\/td>\n<\/tr>\n
256<\/td>\nSECTION 715 FIRE-RESISTANT JOINT SYSTEMS <\/td>\n<\/tr>\n
257<\/td>\nSECTION 716 OPENING PROTECTIVES
TABLE 716.3 MARKING FIRE-RATED GLAZING ASSEMBLIES <\/td>\n<\/tr>\n
259<\/td>\nTABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS <\/td>\n<\/tr>\n
260<\/td>\nTABLE 716.5\u2014continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS <\/td>\n<\/tr>\n
262<\/td>\nTABLE 716.6 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS <\/td>\n<\/tr>\n
263<\/td>\nSECTION 717 DUCTS AND AIR TRANSFER OPENINGS
TABLE 717.3.2.1 FIRE DAMPER RATING <\/td>\n<\/tr>\n
268<\/td>\nSECTION 718 CONCEALED SPACES <\/td>\n<\/tr>\n
270<\/td>\nSECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS <\/td>\n<\/tr>\n
271<\/td>\nSECTION 721 PRESCRIPTIVE FIRE RESISTANCE <\/td>\n<\/tr>\n
272<\/td>\nTABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm <\/td>\n<\/tr>\n
273<\/td>\nTABLE 721.1(1)\u2014continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm <\/td>\n<\/tr>\n
274<\/td>\nTABLE 721.1(1)\u2014continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm <\/td>\n<\/tr>\n
275<\/td>\nTABLE 721.1(1) \u2014continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm <\/td>\n<\/tr>\n
276<\/td>\nTABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS <\/td>\n<\/tr>\n
277<\/td>\nTABLE 721.1(2)\u2014continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS <\/td>\n<\/tr>\n
278<\/td>\nTABLE 721.1(2) \u2014continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS <\/td>\n<\/tr>\n
279<\/td>\nTABLE 721.1(2)\u2014continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS <\/td>\n<\/tr>\n
280<\/td>\nTABLE 721.1(2)\u2014continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS <\/td>\n<\/tr>\n
281<\/td>\nTABLE 721.1(2)\u2014continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS <\/td>\n<\/tr>\n
282<\/td>\nTABLE 721.1(2)\u2014continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS <\/td>\n<\/tr>\n
283<\/td>\nTABLE 721.1(2)\u2014continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS <\/td>\n<\/tr>\n
284<\/td>\nTABLE 721.1(2)\u2014continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS <\/td>\n<\/tr>\n
285<\/td>\nTABLE 721.1(3)\u2014continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS <\/td>\n<\/tr>\n
286<\/td>\nTABLE 721.1(3)\u2014continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS <\/td>\n<\/tr>\n
287<\/td>\nTABLE 721.1(3) \u2014continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS <\/td>\n<\/tr>\n
288<\/td>\nTABLE 721.1(3) \u2014continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS <\/td>\n<\/tr>\n
289<\/td>\nTABLE 721.1(3)\u2014continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEM <\/td>\n<\/tr>\n
290<\/td>\nTABLE 721.1(3)\u2014continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS <\/td>\n<\/tr>\n
291<\/td>\nTABLE 721.1(3)\u2014continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS <\/td>\n<\/tr>\n
292<\/td>\nTABLE 721.1(3)\u2014continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS <\/td>\n<\/tr>\n
293<\/td>\nTABLE 721.1(3)\u2014continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS <\/td>\n<\/tr>\n
294<\/td>\nTABLE 721.1(3)\u2014continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS <\/td>\n<\/tr>\n
295<\/td>\nSECTION 722 CALCULATED FIRE RESISTANCE <\/td>\n<\/tr>\n
296<\/td>\nTABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
EQUATION 7-3
TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4 <\/td>\n<\/tr>\n
297<\/td>\nTABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
EQUATION 7-4 <\/td>\n<\/tr>\n
298<\/td>\nFIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL <\/td>\n<\/tr>\n
299<\/td>\nTABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS <\/td>\n<\/tr>\n
300<\/td>\nEQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS <\/td>\n<\/tr>\n
301<\/td>\nFIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES <\/td>\n<\/tr>\n
302<\/td>\nTABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb <\/td>\n<\/tr>\n
303<\/td>\nTABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches) <\/td>\n<\/tr>\n
304<\/td>\nEQUATION 7-6
TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS <\/td>\n<\/tr>\n
305<\/td>\nEQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
EQUATION 7-8
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS <\/td>\n<\/tr>\n
306<\/td>\nTABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
EQUATION 7-9
TABLE 722.4.1(3) VALUES OF Rn 0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS <\/td>\n<\/tr>\n
307<\/td>\nTABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-10
EQUATION 7-11
FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS <\/td>\n<\/tr>\n
308<\/td>\nEQUATION 7-12
EQUATION 7-13
FIGURE 722.5.1(2) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS <\/td>\n<\/tr>\n
309<\/td>\nFIGURE 722.5.1(3) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD\/SCREW ATTACHMENT SYSTEM
EQUATION 7-14
FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 721.5.1(5) WIDE FLANGE STRUCTURE STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS <\/td>\n<\/tr>\n
310<\/td>\nFIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa,b
FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS <\/td>\n<\/tr>\n
311<\/td>\nTABLE 722.5.1(1) W\/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(2) PROPERTIES OF CONCRETE <\/td>\n<\/tr>\n
312<\/td>\nTABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W\/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES <\/td>\n<\/tr>\n
313<\/td>\nTABLE 722.5.1(4)\u2014continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W\/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES <\/td>\n<\/tr>\n
314<\/td>\nTABLE 722.5.1(4)\u2014continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W\/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES <\/td>\n<\/tr>\n
315<\/td>\nTABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS <\/td>\n<\/tr>\n
316<\/td>\nTABLE 722.5.1(5)\u2014continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS <\/td>\n<\/tr>\n
317<\/td>\nTABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS <\/td>\n<\/tr>\n
318<\/td>\nTABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)] <\/td>\n<\/tr>\n
319<\/td>\nTABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMALWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)] <\/td>\n<\/tr>\n
320<\/td>\nEQUATION 7-15
EQUATION 7-16 <\/td>\n<\/tr>\n
321<\/td>\nFIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17 <\/td>\n<\/tr>\n
322<\/td>\nEQUATION 7-18
TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES
EQUATION 7-19
EQUATION 7-20
EQUATION 7-21 <\/td>\n<\/tr>\n
323<\/td>\nTABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION <\/td>\n<\/tr>\n
324<\/td>\nFIGURE 722.6.3(1) LOAD FIGURE
FIGURE 722.6.3(2) EFFECTIVE LENGTH FACTORS <\/td>\n<\/tr>\n
326<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 7A \u2013 MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE <\/td>\n<\/tr>\n
328<\/td>\nCHAPTER 7A [SFM] MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
SECTION 701A SCOPE, PURPOSE AND APPLICATION <\/td>\n<\/tr>\n
329<\/td>\nSECTION 702A DEFINITIONS
SECTION 703A STANDARDS OF QUALITY <\/td>\n<\/tr>\n
330<\/td>\nSECTION 704A IGNITION-RESISTANT CONSTRUCTION <\/td>\n<\/tr>\n
331<\/td>\nSECTION 705A ROOFING
SECTION 706A VENTS
SECTION 707A EXTERIOR COVERING <\/td>\n<\/tr>\n
333<\/td>\nSECTION 708A EXTERIOR WINDOWS AND DOORS <\/td>\n<\/tr>\n
334<\/td>\nSECTION 709A DECKING
SECTION 710A ACCESSORY STRUCTURES <\/td>\n<\/tr>\n
336<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 8 \u2013 INTERIOR FINISHES <\/td>\n<\/tr>\n
338<\/td>\nCHAPTER 8 INTERIOR FINISHES
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 WALL AND CEILING FINISHES <\/td>\n<\/tr>\n
340<\/td>\nTABLE 803.9 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk <\/td>\n<\/tr>\n
341<\/td>\nSECTION 804 INTERIOR FLOOR FINISH
SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION <\/td>\n<\/tr>\n
342<\/td>\nSECTION 806 DECORATIVE MATERIALS AND TRIM
SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS <\/td>\n<\/tr>\n
344<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 9 \u2013 FIRE PROTECTION SYSTEMS <\/td>\n<\/tr>\n
345<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 9 \u2013 FIRE PROTECTION SYSTEMS\u2014continued <\/td>\n<\/tr>\n
346<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 9 \u2013 FIRE PROTECTION SYSTEMS\u2014continued <\/td>\n<\/tr>\n
347<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 9 \u2013 FIRE PROTECTION SYSTEMS\u2014continued <\/td>\n<\/tr>\n
348<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 9 \u2013 FIRE PROTECTION SYSTEMS\u2014continued <\/td>\n<\/tr>\n
349<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 9 \u2013 FIRE PROTECTION SYSTEMS\u2014continued <\/td>\n<\/tr>\n
350<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 9 \u2013 FIRE PROTECTION SYSTEMS\u2014continued <\/td>\n<\/tr>\n
352<\/td>\nCHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
SECTION 902 DEFINITIONS <\/td>\n<\/tr>\n
353<\/td>\nSECTION 903 AUTOMATIC SPRINKLER SYSTEMS <\/td>\n<\/tr>\n
355<\/td>\n[F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA <\/td>\n<\/tr>\n
357<\/td>\n[F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS <\/td>\n<\/tr>\n
361<\/td>\nSECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS <\/td>\n<\/tr>\n
363<\/td>\nSECTION 905 STANDPIPE SYSTEMS
[F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE CALIFORNIA FIRE CODE <\/td>\n<\/tr>\n
366<\/td>\nSECTION 906 PORTABLE FIRE EXTINGUISHERS
[F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS <\/td>\n<\/tr>\n
367<\/td>\n[F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCH
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS <\/td>\n<\/tr>\n
382<\/td>\n[F] TABLE 907.5.2.3.3 VISIBLE ALARMS <\/td>\n<\/tr>\n
384<\/td>\nSECTION 908 EMERGENCY ALARM SYSTEMS <\/td>\n<\/tr>\n
385<\/td>\nSECTION 909 SMOKE CONTROL SYSTEMS <\/td>\n<\/tr>\n
387<\/td>\nEQUATION 9-1
EQUATION 9-2
EQUATION 9-3 <\/td>\n<\/tr>\n
394<\/td>\nSECTION 910 SMOKE AND HEAT REMOVAL <\/td>\n<\/tr>\n
395<\/td>\nEQUATION 9-4
[F] TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa <\/td>\n<\/tr>\n
396<\/td>\nSECTION 911 FIRE COMMAND CENTER <\/td>\n<\/tr>\n
397<\/td>\nSECTION 912 FIRE DEPARTMENT CONNECTIONS <\/td>\n<\/tr>\n
398<\/td>\nSECTION 913 FIRE PUMPS
SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 915 EMERGENCY RESPONDER RADIO COVERAGE <\/td>\n<\/tr>\n
400<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 10 \u2013 MEANS OF EGRESS <\/td>\n<\/tr>\n
401<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 10 \u2013 MEANS OF EGRESS\u2014continued <\/td>\n<\/tr>\n
402<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 10 \u2013 MEANS OF EGRESS\u2014continued <\/td>\n<\/tr>\n
403<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 10 \u2013 MEANS OF EGRESS\u2014continued <\/td>\n<\/tr>\n
404<\/td>\nCHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
SECTION 1003 GENERAL MEANS OF EGRESS <\/td>\n<\/tr>\n
406<\/td>\nSECTION 1004 OCCUPANT LOAD <\/td>\n<\/tr>\n
407<\/td>\nTABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
SECTION 1005 MEANS OF EGRESS SIZING <\/td>\n<\/tr>\n
408<\/td>\nSECTION 1006 MEANS OF EGRESS ILLUMINATION <\/td>\n<\/tr>\n
409<\/td>\nSECTION 1007 ACCESSIBLE MEANS OF EGRESS <\/td>\n<\/tr>\n
412<\/td>\nSECTION 1008 DOORS, GATES AND TURNSTILES <\/td>\n<\/tr>\n
413<\/td>\nTABLE 1008.1.4.1 REVOLVING DOOR SPEEDS <\/td>\n<\/tr>\n
419<\/td>\nSECTION 1009 STAIRWAYS <\/td>\n<\/tr>\n
423<\/td>\nSECTION 1010 RAMPS <\/td>\n<\/tr>\n
425<\/td>\nSECTION 1011 EXIT SIGNS <\/td>\n<\/tr>\n
426<\/td>\nSECTION 1012 HANDRAILS <\/td>\n<\/tr>\n
427<\/td>\nSECTION 1013 GUARDS <\/td>\n<\/tr>\n
429<\/td>\nSECTION 1014 EXIT ACCESS
TABLE 1014.3 COMMON PATH OF EGRESS TRAVEL <\/td>\n<\/tr>\n
430<\/td>\nSECTION 1015 EXIT AND EXIT ACCESS DOORWAYS
TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY <\/td>\n<\/tr>\n
431<\/td>\nSECTION 1016 EXIT ACCESS TRAVEL DISTANCE
TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCEa <\/td>\n<\/tr>\n
432<\/td>\nSECTION 1017 AISLES
SECTION 1018 CORRIDORS <\/td>\n<\/tr>\n
433<\/td>\nTABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING
TABLE 1018.2 MINIMUM CORRIDOR WIDTH <\/td>\n<\/tr>\n
434<\/td>\nSECTION 1019 EGRESS BALCONIES
SECTION 1020 EXITS
SECTION 1021 NUMBER OF EXITS <\/td>\n<\/tr>\n
435<\/td>\nTABLE 1021.1 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS <\/td>\n<\/tr>\n
436<\/td>\nTABLE 1021.2(1) (IFC [B] TABLE 1021.2(1)) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2, R-3 AND R-4 OCCUPANCIES
TABLE 1021.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES <\/td>\n<\/tr>\n
437<\/td>\nSECTION 1023 EXIT PASSAGEWAYS <\/td>\n<\/tr>\n
438<\/td>\nSECTION 1024 LUMINOUS EGRESS PATH MARKINGS <\/td>\n<\/tr>\n
439<\/td>\nSECTION 1025 HORIZONTAL EXITS <\/td>\n<\/tr>\n
440<\/td>\nSECTION 1026 EXTERIOR EXIT STAIRWAYS AND RAMPS <\/td>\n<\/tr>\n
441<\/td>\nSECTION 1027 EXIT DISCHARGE <\/td>\n<\/tr>\n
442<\/td>\nSECTION 1028 ASSEMBLY <\/td>\n<\/tr>\n
443<\/td>\nTABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY <\/td>\n<\/tr>\n
445<\/td>\nTABLE 1028.10.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS <\/td>\n<\/tr>\n
447<\/td>\nSECTION 1029 EMERGENCY ESCAPE AND RESCUE <\/td>\n<\/tr>\n
450<\/td>\nCHAPTER 11 RESERVED <\/td>\n<\/tr>\n
452<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 11A \u2013 HOUSING ACCESSIBILITY <\/td>\n<\/tr>\n
454<\/td>\nCHAPTER 11A HOUSING ACCESSIBILITY
DIVISION I \u2013 APPLICATION, GENERAL PROVISIONS, AND DEFINITIONS
SECTION 1101A APPLICATION
SECTION 1102A BUILDING ACCESSIBILITY <\/td>\n<\/tr>\n
455<\/td>\nSECTION 1103A DESIGN AND CONSTRUCTION
SECTION 1104A COVERED MULTIFAMILY DWELLINGS <\/td>\n<\/tr>\n
456<\/td>\nSECTION 1105A GARAGES, CARPORTS AND PARKING FACILITIES
SECTION 1106A SITE AND BUILDING CHARACTERISTICS
SECTION 1107A DEFINITIONS <\/td>\n<\/tr>\n
457<\/td>\nDIVISION II \u2013 EXTERIOR FACILITIES
SECTION 1108A GENERAL REQUIREMENTS FOR ACCESSIBLE PARKING AND EXTERIOR ROUTES OF TRAVEL
SECTION 1109A PARKING FACILITIES <\/td>\n<\/tr>\n
459<\/td>\nSECTION 1110A EXTERIOR ROUTES OF TRAVEL <\/td>\n<\/tr>\n
460<\/td>\nSECTION 1111A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1112A CURB RAMPS ON ACCESSIBLE ROUTES
SECTION 1113A WALKS AND SIDEWALKS ON AN ACCESSIBLE ROUTE <\/td>\n<\/tr>\n
461<\/td>\nSECTION 1114A EXTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES <\/td>\n<\/tr>\n
462<\/td>\nSECTION 1115A EXTERIOR STAIRWAYS <\/td>\n<\/tr>\n
463<\/td>\nSECTION 1116A HAZARDS ON ACCESSIBLE ROUTES <\/td>\n<\/tr>\n
464<\/td>\nDIVISION III \u2013 BUILDING FEATURES
SECTION 1117A GENERAL REQUIREMENTS FOR ACCESSIBLE ENTRANCES, EXITS, INTERIOR ROUTES OF TRAVEL AND FACILITY ACCESSIBILITY
SECTION 1118A EGRESS AND AREAS OF REFUGE
SECTION 1119A INTERIOR ROUTES OF TRAVEL
SECTION 1120A INTERIOR ACCESSIBLE ROUTES <\/td>\n<\/tr>\n
465<\/td>\nSECTION 1121A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1122A INTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES <\/td>\n<\/tr>\n
466<\/td>\nSECTION 1123A INTERIOR STAIRWAYS <\/td>\n<\/tr>\n
467<\/td>\nSECTION 1124A ELEVATORS AND PLATFORM (WHEELCHAIR) LIFTS <\/td>\n<\/tr>\n
469<\/td>\nSECTION 1125A HAZARDS ON ACCESSIBLE ROUTES
SECTION 1126A DOORS <\/td>\n<\/tr>\n
471<\/td>\nSECTION 1127A COMMON USE FACILITIES <\/td>\n<\/tr>\n
479<\/td>\nDIVISION IV \u2013 DWELLING UNIT FEATURES
SECTION 1128A COVERED DWELLING UNITS
SECTION 1129A RESERVED
SECTION 1130A ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DWELLING UNITS
SECTION 1131A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1132A DOORS <\/td>\n<\/tr>\n
481<\/td>\nSECTION 1133A KITCHENS <\/td>\n<\/tr>\n
482<\/td>\nSECTION 1134A BATHING AND TOILET FACILITIES <\/td>\n<\/tr>\n
485<\/td>\nSECTION 1135A LAUNDRY ROOMS
SECTION 1136A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS <\/td>\n<\/tr>\n
486<\/td>\nDIVISION V \u2013 FEATURES COMMON TO EXTERIOR AND INTERIOR OF BUILDINGS
SECTION 1137A OTHER FEATURES AND FACILITIES
SECTION 1138A SPACE ALLOWANCES AND REACH RANGES <\/td>\n<\/tr>\n
488<\/td>\nSECTION 1139A ACCESSIBLE DRINKING FOUNTAINS <\/td>\n<\/tr>\n
489<\/td>\nSECTION 1140A ACCESSIBLE TELEPHONES
SECTION 1141A ACCESSIBLE SWIMMING POOLS <\/td>\n<\/tr>\n
490<\/td>\nSECTION 1142A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS
SECTION 1143A SIGNAGE <\/td>\n<\/tr>\n
491<\/td>\nTABLE 1143A.5 VISUAL CHARACTER HEIGHT <\/td>\n<\/tr>\n
492<\/td>\nTABLE 1143A.7.1 BRAILLE DIMENSIONS
SECTION 1144A RESERVED
SECTION 1145A RESERVED
SECTION 1146A RESERVED
SECTION 1147A RESERVED
SECTION 1148A RESERVED
SECTION 1149A RESERVED <\/td>\n<\/tr>\n
493<\/td>\nDIVISION VI \u2013 SITE IMPRACTICALITY TESTS
SECTION 1150A SITE IMPRACTICALITY TESTS
TEST NO. 1\u2014INDIVIDUAL BUILDING TEST
TEST NO. 2\u2014SITE ANALYSIS TEST <\/td>\n<\/tr>\n
494<\/td>\nTEST NO. 3\u2014UNUSUAL CHARACTERISTICS TEST <\/td>\n<\/tr>\n
495<\/td>\nDIVISION VII \u2013 FIGURES
FIGURE 11A-1A INTERNATIONAL ACCESSIBILITY SYMBOL <\/td>\n<\/tr>\n
496<\/td>\nFIGURE 11A-1B HEADROOM CLEARANCE AND OVERHANGING OBSTRUCTION <\/td>\n<\/tr>\n
497<\/td>\nFIGURE 11A-1C WIDTH OF ACCESSIBLE ROUTE AT TURNS <\/td>\n<\/tr>\n
498<\/td>\nFIGURE 11A-1D WHEELCHAIR TURNING SPACE
FIGURE 11A-1E WHEELCHAIR PASSAGE WIDTH <\/td>\n<\/tr>\n
499<\/td>\nFIGURE 11A-1F CHANGE IN LEVEL <\/td>\n<\/tr>\n
500<\/td>\nFIGURE 11A-1G MINIMUM CLEAR FLOOR SPACE FOR WHEELCHAIRS <\/td>\n<\/tr>\n
501<\/td>\nFIGURE 11A-1H MINIMUM CLEAR FLOOR SPACE IN ALCOVES <\/td>\n<\/tr>\n
502<\/td>\nFIGURE 11A-1I FORWARD REACH <\/td>\n<\/tr>\n
503<\/td>\nFIGURE 11A-1J SIDE REACH <\/td>\n<\/tr>\n
504<\/td>\nFIGURE 11A-1K <\/td>\n<\/tr>\n
505<\/td>\nFIGURE 11A-1L INTERIOR ACCESSIBLE ROUTE (CORRIDOR) OVER 200 FEET; OCCUPANT LOAD 10 OR MORE <\/td>\n<\/tr>\n
506<\/td>\nFIGURE 11A-2B SINGLE AND VAN ACCESSIBLE PARKING STALLS <\/td>\n<\/tr>\n
507<\/td>\nFIGURE 11A-2C DIAGONAL PARKING STALLS <\/td>\n<\/tr>\n
508<\/td>\nFIGURE 11A-3A CURB DETAILS <\/td>\n<\/tr>\n
509<\/td>\nFIGURE 11A-3B CURB DETAIL <\/td>\n<\/tr>\n
510<\/td>\nFIGURE 11A-3C CURB DETAIL <\/td>\n<\/tr>\n
511<\/td>\nFIGURE 11A-3D CURB DETAIL <\/td>\n<\/tr>\n
512<\/td>\nFIGURE 11A-3E CURB DETAIL <\/td>\n<\/tr>\n
513<\/td>\nFIGURE 11A-3F CURB DETAIL – SIDDEWALK LESS THAN 60\u201d\u00b3 WIDE
FIGURE 11A-3G CURB DETAIL <\/td>\n<\/tr>\n
514<\/td>\nFIGURE 11A-3H CURB DETAIL
FIGURE 11A-3I CURB DETAIL <\/td>\n<\/tr>\n
515<\/td>\nFIGURE 11A-3J CURB DETAIL
FIGURE 11A-3K CURB DETAIL <\/td>\n<\/tr>\n
516<\/td>\nFIGURE 11A-3L CURB SECTIONS <\/td>\n<\/tr>\n
517<\/td>\nFIGURE 11A-5A RAMPS AND SIDEWALKS <\/td>\n<\/tr>\n
518<\/td>\nFIGURE 11A-6A WARNING STRIPING AND HANDRAIL EXTENSIONS <\/td>\n<\/tr>\n
519<\/td>\nFIGURE 11A-6B STAIR HANDRAILS <\/td>\n<\/tr>\n
520<\/td>\nFIGURE 11A-6C RAMP DIMENSIONS <\/td>\n<\/tr>\n
521<\/td>\nFIGURE 11A-6D RAMP LANDING AND DOORWAY <\/td>\n<\/tr>\n
522<\/td>\nFIGURE 11A-6D RAMP LANDING AND DOORWAY <\/td>\n<\/tr>\n
523<\/td>\nFIGURE 11A-6E STAIR HANDRAILS <\/td>\n<\/tr>\n
524<\/td>\nFIGURE 11A-7A MINIMUM DIMENSIONS OF ELEVATOR CARS <\/td>\n<\/tr>\n
525<\/td>\nFIGURE 11A-7B ELEVATOR CONTROL PANEL <\/td>\n<\/tr>\n
526<\/td>\nFIGURE 11A-7C HOISTWAY AND ELEVATOR ENTRANCES
FIGURE 11A-7D GRAPH OF TIMING EQUATION <\/td>\n<\/tr>\n
527<\/td>\nFIGURE 11A-8A FRONT APPROACHES\u2014SWINGING DOORS
FIGURE 11A-8B HINGE SIDE APPROACHES\u2014SWINGING DOORS <\/td>\n<\/tr>\n
528<\/td>\nFIGURE 11A-8C LATCH SIDE APPROACH\u2014SWINGING DOORS
FIGURE 11A-8D FRONT APPROACH\u2014SLIDING DOORS AND FOLDING DOORS
FIGURE 11A-8E SLIDE SIDE APPROACH\u2014SLIDING DOORS AND FOLDING DOORS
FIGURE 11A-8F LATCH SIDE APPROACH\u2014SLIDING DOORS AND FOLDING DOORS <\/td>\n<\/tr>\n
529<\/td>\nFIGURE 11A-8G VESTIBULE <\/td>\n<\/tr>\n
530<\/td>\nFIGURE 11A-8H VESTIBULE (SERVING OTHER THAN A REQUIRED EXIT STAIRWAY) <\/td>\n<\/tr>\n
531<\/td>\nFIGURE 11A-8I THRESHOLDS
FIGURE 11A-8J PLATFORM AT SECONDARY EXTERIOR DOOR
FIGURE 11A-8K RAMP AT SECONDARY EXTERIOR DOOR <\/td>\n<\/tr>\n
532<\/td>\nFIGURE 11A-9A TOILET FACILITIES <\/td>\n<\/tr>\n
533<\/td>\nFIGURE 11A-9B WATER CLOSETS <\/td>\n<\/tr>\n
534<\/td>\nFIGURE 11A-9C GRAB BARS <\/td>\n<\/tr>\n
535<\/td>\nFIGURE 11A-9D KNEE AND TOE SPACE <\/td>\n<\/tr>\n
536<\/td>\nFIGURE 11A-9E CLEAR FLOOR SPACE AT BATHTUBS <\/td>\n<\/tr>\n
537<\/td>\nFIGURE 11A-9F GRAB BARS AT BATHTUBS <\/td>\n<\/tr>\n
538<\/td>\nFIGURE 11A-9G REINFORCEMENT FOR GRAB BARS <\/td>\n<\/tr>\n
539<\/td>\nFIGURE 11A-9H STANDARD ROLL-IN SHOWER <\/td>\n<\/tr>\n
540<\/td>\nFIGURE 1A-9I SHOWER SEATS AND GRAB BARS <\/td>\n<\/tr>\n
541<\/td>\nFIGURE 11A-9J OPEN SHOWER <\/td>\n<\/tr>\n
542<\/td>\nFIGURE 11A-9K ALTERNATE ROLL-IN SHOWER <\/td>\n<\/tr>\n
543<\/td>\nFIGURE 11A-9L SHOWER WITH WATER CLOSET
FIGURE 11A-9M WING WALL OR CABINET AT WATER CLOSET <\/td>\n<\/tr>\n
544<\/td>\nFIGURE 11A-10A KITCHEN SPECIFICATIONS <\/td>\n<\/tr>\n
545<\/td>\nFIGURE 11A-11A DRINKING FOUNTAINS <\/td>\n<\/tr>\n
546<\/td>\nFIGURE 11A-11B MOUNTING HEIGHTS AND CLEARANCES FOR TELEPHONES <\/td>\n<\/tr>\n
547<\/td>\nFIGURE 11A-1E INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS <\/td>\n<\/tr>\n
548<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 11B \u2013 ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLICLY FUNDED HOUSING <\/td>\n<\/tr>\n
550<\/td>\nCHAPTER 11B ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
DIVISION 1: APPLICATION AND ADMINISTRATION
11B-101 PURPOSE
11B-102 DIMENSIONS FOR ADULTS AND CHILDREN
11B-103 EQUIVALENT FACILITATION
11B-104 CONVENTIONS
11B-105 REFERENCED STANDARDS
11B-106 DEFINITIONS
FIGURE 11B-104 GRAPHIC CONVENTION FOR FIGURES <\/td>\n<\/tr>\n
552<\/td>\n11B-107 SPECIAL CONDITIONS APPEALS ACTION
11B-108 MAINTENANCE OF ACCESSIBLE FEATURES <\/td>\n<\/tr>\n
553<\/td>\nDIVISION 2: SCOPING REQUIREMENTS
11B-201 APPLICATION
11B-202 EXISTING BUILDINGS AND FACILITIES <\/td>\n<\/tr>\n
555<\/td>\n11B-203 GENERAL EXCEPTIONS <\/td>\n<\/tr>\n
556<\/td>\n11B-204 PROTRUDING OBJECTS
11B-205 OPERABLE PARTS
11B-206 ACCESSIBLE ROUTES <\/td>\n<\/tr>\n
560<\/td>\n11B-207 ACCESSIBLE MEANS OF EGRESS
11B-208 PARKING SPACES <\/td>\n<\/tr>\n
561<\/td>\nTABLE 11B-208.2 PARKING SPACES <\/td>\n<\/tr>\n
562<\/td>\n11B-209 PASSENGER LOADING ZONES AND BUS STOPS
11B-210 STAIRWAYS
11B-211 DRINKING FOUNTAINS <\/td>\n<\/tr>\n
563<\/td>\n11B-212 KITCHENS, KITCHENETTES, WET BARS AND SINKS
11B-213 TOILET FACILITIES AND BATHING FACILITIES
\n <\/td>\n<\/tr>\n
564<\/td>\n11B-214 WASHING MACHINES AND CLOTHES DRYERS
11B-215 FIRE ALARM SYSTEMS
11B-216 SIGNS <\/td>\n<\/tr>\n
566<\/td>\n11B-217 TELEPHONES
TABLE 11B-217.2 WHEELCHAIR ACCESSIBLE TELEPHONES <\/td>\n<\/tr>\n
567<\/td>\n11B-218 TRANSPORTATION FACILITIES
11B-219 ASSISTIVE LISTENING SYSTEMS <\/td>\n<\/tr>\n
568<\/td>\n11B-220 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES
11B-221 ASSEMBLY AREAS
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS <\/td>\n<\/tr>\n
570<\/td>\n11B-222 DRESSING, FITTING AND LOCKER ROOMS
11B-223 MEDICAL CARE AND LONG-TERM CARE FACILITIES <\/td>\n<\/tr>\n
571<\/td>\n11B-224 TRANSIENT LODGING GUEST ROOMS <\/td>\n<\/tr>\n
572<\/td>\nTABLE 11B-224.2 GUEST ROOMS WITH MOBILITY FEATURES
TABLE 11B-224.4 GUEST ROOMS WITH COMMUNICATION FEATURES
11B-225 STORAGE <\/td>\n<\/tr>\n
573<\/td>\nTABLE 11B-225.3 SELF-SERVICE STORAGE FACILITIES
11B-226 DINING SURFACES AND WORK SURFACES
11B-227 SALES AND SERVICE
TABLE 11B-227.2 CHECK-OUT AISLES <\/td>\n<\/tr>\n
574<\/td>\n11B-228 DEPOSITORIES, VENDING MACHINES, CHANGE MACHINES, MAIL BOXES AND FUEL DISPENSERS
11B-229 WINDOWS
11B-230 TWO-WAY COMMUNICATION SYSTEMS
11B-231 JUDICIAL FACILITIES
11B-232 DETENTION FACILITIES AND CORRECTIONAL FACILITIES <\/td>\n<\/tr>\n
575<\/td>\n11B-233 RESIDENTIAL FACILITIES <\/td>\n<\/tr>\n
577<\/td>\n11B-234 AMUSEMENT RIDES
11B-235 RECREATIONAL BOATING FACILITIES
TABLE 11B-235.2 BOAT SLIPS <\/td>\n<\/tr>\n
578<\/td>\n11B-236 EXERCISE MACHINES AND EQUIPMENT
11B-237 FISHING PIERS AND PLATFORMS
11B-238 GOLF FACILITIES
11B-239 MINIATURE GOLF FACILITIES
11B-240 PLAY AREAS <\/td>\n<\/tr>\n
579<\/td>\nTABLE 11B-240.2.1.2 NUMBER AND TYPES OF GROUND LEVEL PLAY COMPONENTS REQUIRED TO BE ON ACCESSIBLE ROUTES
11B-241 SAUNAS AND STEAM ROOMS
11B-242 SWIMMING POOLS, WADING POOLS, AND SPAS
11B-243 SHOOTING FACILITIES WITH FIRING POSITIONS
11B-244 RELIGIOUS FACILITIES <\/td>\n<\/tr>\n
580<\/td>\n11B-245 COMMERCIAL FACILITIES LOCATED IN PRIVATE RESIDENCES
11B-246 OUTDOOR DEVELOPED AREAS
11B-247 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE <\/td>\n<\/tr>\n
581<\/td>\nDIVISION 3: BUILDING BLOCKS
11B-301 GENERAL
11B-302 FLOOR OR GROUND SURFACES
FIGURE 11B-302.2 CARPET PILE HEIGHT
FIGURE 11B-302.3 ELONGATED OPENINGS IN FLOOR OR GROUND SURFACES
11B-303 CHANGES IN LEVEL
FIGURE 11B-303.2 VERTICAL CHANGE IN LEVEL
FIGURE 11B-303.3 BEVELED CHANGE IN LEVEL <\/td>\n<\/tr>\n
582<\/td>\n11B-304 TURNING SPACE
FIGURE 11B-304.3.2 T-SHAPED TURNING SPACE
11B-305 CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.5 POSITION OF CLEAR FLOOR OR GROUND SPACE <\/td>\n<\/tr>\n
583<\/td>\nFIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH
FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH
11B-306 KNEE AND TOE CLEARANCE
FIGURE 11B-306.2 TOE CLEARANCE <\/td>\n<\/tr>\n
584<\/td>\nFIGURE 11B-306.3 KNEE CLEARANCE
11B-307 PROTRUDING OBJECTS
FIGURE 11B-307.2 LIMITS OF PROTRUDING OBJECTS
FIGURE 11B-307.3 POST-MOUNTED PROTRUDING OBJECTS <\/td>\n<\/tr>\n
585<\/td>\nFIGURE 11B-307.4 VERTICAL CLEARANCE
11B-308 REACH RANGES
FIGURE 11B-308.2.1 UNOBSTRUCTED FORWARD REACH
FIGURE 11B-308.2.2 OBSTRUCTED HIGH FORWARD REACH <\/td>\n<\/tr>\n
586<\/td>\nFIGURE 11B-308.3.1 UNOBSTRUCTED SIDE REACH
FIGURE 11B-308.3.2 OBSTRUCTED HIGH SIDE REACH
11B-309 OPERABLE PARTS <\/td>\n<\/tr>\n
587<\/td>\nDIVISION 4: ACCESSIBLE ROUTES
11B-401 GENERAL
11B-402 ACCESSIBLE ROUTES
11B-403 WALKING SURFACES
FIGURE 11B-403.5.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE <\/td>\n<\/tr>\n
588<\/td>\nFIGURE 11B-403.5.2 CLEAR WIDTH AT TURN
11B-404 DOORS, DOORWAYS, AND GATES <\/td>\n<\/tr>\n
589<\/td>\nFIGURE 11B-404.2.3 CLEAR WIDTH OF DOORWAYS
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES <\/td>\n<\/tr>\n
590<\/td>\nFIGURE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES <\/td>\n<\/tr>\n
591<\/td>\nFIGURE 11B-404.2.4.1\u2014continued MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES <\/td>\n<\/tr>\n
592<\/td>\nTABLE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS
FIGURE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS <\/td>\n<\/tr>\n
593<\/td>\nFIGURE 11B-404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES
FIGURE 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES <\/td>\n<\/tr>\n
595<\/td>\n11B-405 RAMPS <\/td>\n<\/tr>\n
596<\/td>\nFIGURE 11B-405.7 RAMP LANDINGS
FIGURE 11B-405.9.2 CURB OR BARRIER EDGE PROTECTION
11B-406 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS <\/td>\n<\/tr>\n
597<\/td>\nFIGURE 11B-406.2.2 SIDES OF CURB RAMPS
FIGURE 11B-406.3.2 PARALLEL CURB RAMPS
FIGURE 11B-406.5.3 LANDINGS AT THE TOP OF CURB RAMPS <\/td>\n<\/tr>\n
598<\/td>\nFIGURE 11B-406.5.7 COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS
FIGURE 11B-406.5.10 DIAGONAL OR CORNER TYPE CURB RAMPS
FIGURE 11B-406.6 ISLANDS IN CROSSINGS
11B-407 ELEVATORS <\/td>\n<\/tr>\n
599<\/td>\nFIGURE 11B-407.2.2.2 VISIBLE HALL SIGNALS <\/td>\n<\/tr>\n
600<\/td>\nFIGURE 11B-407.2.3.1 FLOOR DESIGNATIONS ON JAMBS OF ELEVATOR HOISTWAY ENTRANCE
FIGURE 11B-407.2.3.2 CAR DESIGNATIONS ON JAMBS OF DESTINATION-ORIENTED ELEVATOR HOISTWAY ENTRANCES <\/td>\n<\/tr>\n
601<\/td>\nTABLE 11B-407.4.1 ELEVATOR CAR DIMENSIONS <\/td>\n<\/tr>\n
602<\/td>\nFIGURE 11B-407.4.1 ELEVATOR CAR DIMENSIONS <\/td>\n<\/tr>\n
603<\/td>\nTABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION <\/td>\n<\/tr>\n
604<\/td>\n11B-408 LIMITED-USE\/LIMITED-APPLICATION ELEVATORS <\/td>\n<\/tr>\n
605<\/td>\nFIGURE 11B-408.4.1 LIMITED-USE\/LIMITED-APPLICATION (LULA) ELEVATOR CAR DIMENSIONS
11B-409 PRIVATE RESIDENCE ELEVATORS
FIGURE 11B-409.4.6.2 LOCATION OF PRIVATE RESIDENCE ELEVATOR CONTROL PANEL <\/td>\n<\/tr>\n
606<\/td>\n11B-410 PLATFORM LIFTS
FIGURE 11B-410.6 PLATFORM LIFT DOORS AND GATES <\/td>\n<\/tr>\n
607<\/td>\nDIVISION 5: GENERAL SITE AND BUILDING ELEMENTS
11B-501 GENERAL
11B-502 PARKING SPACES
FIGURE 11B-502.2 VEHICLE PARKING SPACES <\/td>\n<\/tr>\n
608<\/td>\nFIGURE 11B-502.3 PARKING SPACE ACCESS AISLE <\/td>\n<\/tr>\n
609<\/td>\nFIGURE 11B-502.3.3 ANGLED AND PERPENDICULAR PARKING IDENTIFICATION <\/td>\n<\/tr>\n
610<\/td>\n11B-503 PASSENGER DROP-OFF AND LOADING ZONES
FIGURE 11B-503.3 PASSENGER DROP-OFF AND LOADING ZONE ACCESS AISLE <\/td>\n<\/tr>\n
611<\/td>\n11B-504 STAIRWAYS
FIGURE 11B-504.5 STAIR NOSINGS
11B-505 HANDRAILS <\/td>\n<\/tr>\n
612<\/td>\nFIGURE 11B-505.4 HANDRAIL HEIGHT
FIGURE 11B-505.5 HANDRAIL CLEARANCE
FIGURE 11B-505.6 HORIZONTAL PROJECTIONS BELOW GRIPPING SURFACE
FIGURE 11B-505.7.2 HANDRAIL NON-CIRCULAR CROSS SECTION <\/td>\n<\/tr>\n
613<\/td>\nFIGURE 11B-505.10.1 TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS
FIGURE 11B-505.10.2 TOP HANDRAIL EXTENSION AT STAIRS
FIGURE 11B-505.10.3 BOTTOM HANDRAIL EXTENSION AT STAIRS <\/td>\n<\/tr>\n
614<\/td>\nDIVISION 6: PLUMBING ELEMENTS AND FACILITIES
11B-601 GENERAL
11B-602 DRINKING FOUNTAINS
FIGURE 11B-602.5 DRINKING FOUNTAIN SPOUT LOCATION
11B-603 TOILET AND BATHING ROOMS <\/td>\n<\/tr>\n
615<\/td>\n11B-604 WATER CLOSETS AND TOILET COMPARTMENTS
FIGURE 11B-604.2 WATER CLOSET LOCATION
FIGURE 11B-604.3.1 SIZE OF CLEARANCE AT WATER CLOSETS
FIGURE 11B-604.3.2 (EXCEPTION) OVERLAP OF WATER CLOSET CLEARANCE IN RESIDENTIAL DWELLING UNITS <\/td>\n<\/tr>\n
616<\/td>\nFIGURE 11B-604.5.1 SIDE WALL GRAB BAR AT WATER CLOSETS
FIGURE 11B-604.5.2 REAR WALL GRAB BAR AT WATER CLOSETS <\/td>\n<\/tr>\n
617<\/td>\nFIGURE 11B-604.7 DISPENSER OUTLET LOCATION
FIGURE 11B-604.8.1.1.2 MANEUVERING SPACE WITH SIDE-OPENING DOOR <\/td>\n<\/tr>\n
618<\/td>\nFIGURE 11B-604.8.1.1.3 MANEUVERING SPACE WITH END-OPENING DOOR
FIGURE 11B-604.8.1.2 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS
11B-604.8.2 AMBULATORY ACCESSIBLE TOILET COMPARTMENT <\/td>\n<\/tr>\n
619<\/td>\nFIGURE 11B-604.8.1.4 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCE
TABLE 11B-604.9 SUGGESTED DIMENSIONS FOR CHILDREN\u2019S USE <\/td>\n<\/tr>\n
620<\/td>\n11B-605 URINALS
FIGURE 11B-605.2 HEIGHT AND DEPTH OF URINALS
11B-606 LAVATORIES AND SINKS
11B-607 BATHTUBS <\/td>\n<\/tr>\n
621<\/td>\nFIGURE 11B-607.2 CLEARANCE FOR BATHTUBS <\/td>\n<\/tr>\n
622<\/td>\nFIGURE 11B-607.4.1 GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS
FIGURE 11B-607.4.2 GRAB BARS FOR BATHTUBS WITH REMOVABLE IN-TUB SEATS
FIGURE 11B-607.5 BATHTUB CONTROL LOCATION <\/td>\n<\/tr>\n
623<\/td>\n11B-608 SHOWER COMPARTMENTS
FIGURE 11B-608.2.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
FIGURE 11B-608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
FIGURE 11B-608.3.2 GRAB BARS FOR STANDARD ROLL-IN TYPE SHOWER <\/td>\n<\/tr>\n
624<\/td>\nFIGURE 11B-608.3.3 GRAB BARS FOR ALTERNATE ROLL-IN TYPE SHOWERS
FIGURE 11B-608.5.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION
FIGURE 11B-608.5.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION <\/td>\n<\/tr>\n
625<\/td>\n11B-609 GRAB BARS
FIGURE 11B-609.2.2 GRAB BAR NON-CIRCULAR CROSS SECTION
FIGURE 11B-609.3 SPACING OF GRAB BARS
11B-610 SEATS <\/td>\n<\/tr>\n
626<\/td>\nFIGURE 11B-610.2 BATHTUB SEATS
FIGURE 11B-610.3 EXTENT OF SEAT
FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT
FIGURE 11B-610.3.2 L-SHAPED SHOWER SEAT
11B-611 WASHING MACHINES AND CLOTHES DRYERS <\/td>\n<\/tr>\n
627<\/td>\nFIGURE 11B-611.4 HEIGHT OF LAUNDRY COMPARTMENT OPENING
11B-612 SAUNAS AND STEAM ROOMS <\/td>\n<\/tr>\n
628<\/td>\nDIVISION 7: COMMUNICATION ELEMENTS AND FEATURES
11B-701 GENERAL
11B-702 FIRE ALARM SYSTEMS
11B-703 SIGNS
FIGURE 11B-703.2.5 HEIGHT OF RAISED CHARACTERS <\/td>\n<\/tr>\n
629<\/td>\nTABLE 11B-703.3.1 BRAILLE DIMENSIONS
FIGURE 11B-703.3.1 BRAILLE MEASUREMENT
FIGURE 11B-703.3.2 POSITION OF BRAILLE
FIGURE 11B-703.4.1 HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND <\/td>\n<\/tr>\n
630<\/td>\nFIGURE 11B-703.4.2 LOCATION OF TACTILE SIGNS AT DOORS
TABLE 11B-703.5.5 VISUAL CHARACTER HEIGHT <\/td>\n<\/tr>\n
631<\/td>\nFIGURE 11B-703.6.1 PICTOGRAM FIELD
FIGURE 11B-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY
FIGURE 11B-703.7.2.2 INTERNATIONAL SYMBOL OF TTY <\/td>\n<\/tr>\n
632<\/td>\nFIGURE 11B-703.7.2.3 VOLUME CONTROL TELEPHONE
FIGURE 11B-703.7.2.4 INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
FIGURE 11B-703.7.2.5 CLEANER AIR SYMBOL <\/td>\n<\/tr>\n
633<\/td>\n11B-704 TELEPHONES
FIGURE 11B-704.2.1.1 PARALLEL APPROACH TO TELEPHONE
FIGURE 11B-704.2.1.2 FORWARD APPROACH TO TELEPHONE
11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE <\/td>\n<\/tr>\n
634<\/td>\nFIGURE 11B-705.1 SIZE AND SPACING OF TRUNCATED DOMES <\/td>\n<\/tr>\n
635<\/td>\nFIGURE 11B-705.2 DETECTABLE DIRECTIONAL TEXTURE
11B-706 ASSISTIVE LISTENING SYSTEMS
11B-707 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES <\/td>\n<\/tr>\n
636<\/td>\nFIGURE 11B-707.6.2 NUMERIC KEY LAYOUT <\/td>\n<\/tr>\n
637<\/td>\n11B-708 TWO-WAY COMMUNICATION SYSTEMS <\/td>\n<\/tr>\n
638<\/td>\nDIVISION 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
11B-801 GENERAL
11B-802 WHEELCHAIR SPACES, COMPANION SEATS, AND DESIGNATED AISLE SEATS AND SEMI-AMBULANT SEATS
FIGURE 11B-802.1.2 WIDTH OF WHEELCHAIR SPACES
FIGURE 11B-802.1.3 DEPTH OF WHEELCHAIR SPACES
FIGURE 11B-802.2.1.1 LINES OF SIGHT OVER THE HEADS OF SEATED SPECTATORS
FIGURE 11B-802.2.1.2 LINES OF SIGHT BETWEEN THE HEADS OF SEATED SPECTATORS <\/td>\n<\/tr>\n
639<\/td>\nFIGURE 11B-802.2.2.1 LINES OF SIGHT OVER THE HEADS OF STANDING SPECTATORS
FIGURE 11B-802.2.2.2 LINES OF SIGHT BETWEEN THE HEADS OF STANDING SPECTATORS
11B-803 DRESSING, FITTING, AND LOCKER ROOMS
11B-804 KITCHENS AND KITCHENETTES <\/td>\n<\/tr>\n
640<\/td>\nFIGURE 11B-804.2.1 PASS THROUGH KITCHENS
FIGURE 11B-804.2.2 U-SHAPED KITCHENS <\/td>\n<\/tr>\n
641<\/td>\n11B-805 MEDICAL CARE AND LONG-TERM FACILITIES <\/td>\n<\/tr>\n
642<\/td>\n11B-806 TRANSIENT LODGING GUEST ROOMS
11B-807 HOLDING CELLS AND HOUSING CELLS <\/td>\n<\/tr>\n
643<\/td>\n11B-808 COURTROOMS
11B-809 RESIDENTIAL DWELLING UNITS <\/td>\n<\/tr>\n
644<\/td>\n11B-810 TRANSPORTATION FACILITIES
FIGURE 11B-810.2.2 DIMENSIONS OF BUS BOARDING AND ALIGHTING AREAS
FIGURE 11B-810.3 BUS SHELTERS <\/td>\n<\/tr>\n
645<\/td>\nFIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS
11B-811 STORAGE <\/td>\n<\/tr>\n
646<\/td>\nDIVISION 9: BUILT-IN ELEMENTS
11B-901 GENERAL
11B-902 DINING SURFACES AND WORK SURFACES
11B-903 BENCHES
FIGURE 11B-903.4 BENCH BACK SUPPORT
11B-904 CHECK-OUT AISLES AND SALES AND SERVICE COUNTERS <\/td>\n<\/tr>\n
647<\/td>\nFIGURE 11B-904.3.2 CHECK-OUT AISLE COUNTERS
FIGURE 11B-904.4 (EXCEPTION) ALTERATION OF SALES AND SERVICE COUNTERS <\/td>\n<\/tr>\n
648<\/td>\nDIVISION 10: RECREATION FACILITIES
11B-1001 GENERAL
11B-1002 AMUSEMENT RIDES
FIGURE 11B-1002.4.4.3 PROTRUSIONS IN WHEELCHAIR SPACES IN AMUSEMENT RIDES <\/td>\n<\/tr>\n
649<\/td>\n11B-1003 RECREATIONAL BOATING FACILITIES <\/td>\n<\/tr>\n
650<\/td>\nFIGURE 11B-1003.3.1 BOAT SLIP CLEARANCE
FIGURE 11B-1003.3.1 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOAT SLIPS
FIGURE 11B-1003.3.1 (EXCEPTION 2) EDGE PROTECTION AT BOAT SLIPS <\/td>\n<\/tr>\n
651<\/td>\nFIGURE 11B-1003.3.2 BOARDING PIER CLEARANCE
FIGURE 11B-1003.3.2 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOARDING PIERS
FIGURE 11B-1003.3.2 (EXCEPTION 2) EDGE PROTECTION AT BOARDING PIERS <\/td>\n<\/tr>\n
652<\/td>\n11B-1004 EXERCISE MACHINES AND EQUIPMENT
11B-1005 FISHING PIERS AND PLATFORMS
FIGURE 11B-1005.3.2 EXTENDED GROUND OR DECK SURFACE AT FISHING PIERS AND PLATFORMS
11B-1006 GOLF FACILITIES <\/td>\n<\/tr>\n
653<\/td>\n11B-1007 MINIATURE GOLF FACILITIES
FIGURE 11B-1007.3.2 GOLF CLUB REACH RANGE AREA
11B-1008 PLAY AREAS <\/td>\n<\/tr>\n
655<\/td>\nFIGURE 11B-1008.3.1 TRANSFER PLATFORMS
FIGURE 11B-1008.3.2 TRANSFER STEPS
11B-1009 SWIMMING POOLS, WADING POOLS, AND SPAS <\/td>\n<\/tr>\n
656<\/td>\nFIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION
FIGURE 11B-1009.2.3 CLEAR DECK SPACE AT POOL LIFTS
FIGURE 11B-1009.2.4 POOL LIFT SEAT HEIGHT
FIGURE 11B-1009.2.8 POOL LIFT SUBMERGED DEPTH <\/td>\n<\/tr>\n
657<\/td>\nFIGURE 11B-1009.3.2 SLOPED ENTRY SUBMERGED DEPTH
FIGURE 11B-1009.3.3 HANDRAILS FOR SLOPED ENTRY
FIGURE 11B-1009.4.1 CLEAR DECK SPACE AT TRANSFER WALLS
FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT <\/td>\n<\/tr>\n
658<\/td>\nFIGURE 11B-1009.4.3 DEPTH AND LENGTH OF TRANSFER WALLS
FIGURE 11B-1009.4.5 GRAB BARS FOR TRANSFER WALLS
FIGURE 11B-1009.5.1 SIZE OF TRANSFER PLATFORM
FIGURE 11B-1009.5.2 CLEAR DECK SPACE AT TRANSFER PLATFORM <\/td>\n<\/tr>\n
659<\/td>\nFIGURE 11B-1009.5.4 TRANSFER STEPS
FIGURE 11B-1009.5.6 SIZE OF TRANSFER STEPS
FIGURE 11B-1009.5.7 GRAB BARS
11B-1010 SHOOTING FACILITIES WITH FIRING POSITIONS <\/td>\n<\/tr>\n
660<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 12 \u2013 INTERIOR ENVIRONMENT <\/td>\n<\/tr>\n
662<\/td>\nCHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 VENTILATION <\/td>\n<\/tr>\n
664<\/td>\nSECTION 1204 TEMPERATURE CONTROL
SECTION 1205 LIGHTING <\/td>\n<\/tr>\n
665<\/td>\nSECTION 1206 YARDS OR COURTS
SECTION 1207 SOUND TRANSMISSION
SECTION 1208 INTERIOR SPACE DIMENSIONS <\/td>\n<\/tr>\n
666<\/td>\nSECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 TOILET AND BATHROOM REQUIREMENTS <\/td>\n<\/tr>\n
667<\/td>\nSECTION 1211 [HCD 1 & HCD 2] GARAGE DOOR SPRINGS
SECTION 1212 [HCD 1] POLLUTANT CONTROL
SECTION 1213 RESERVED
SECTION 1214 RESERVED
SECTION 1215 RESERVED
SECTION 1216 RESERVED
SECTION 1217 RESERVED
SECTION 1218 RESERVED <\/td>\n<\/tr>\n
668<\/td>\nSECTION 1219 RESERVED
SECTION 1220 RESERVED
SECTION 1221 RESERVED
SECTION 1222 RESERVED
SECTION 1223 RESERVED
SECTION 1224 [OSHPD 1] HOSPITALS <\/td>\n<\/tr>\n
671<\/td>\nTABLE 1224.4.6.1 STATION OUTLETS FOR OXYGEN, VACUUM (SUCTION), AND MEDICAL AIR1, 6 <\/td>\n<\/tr>\n
672<\/td>\nTABLE 1224.4.6.5 [OSHPD 1, 2, 3 & 4] LOCATION OF NURSE CALL DEVICES KEY: \u00b7 Required <\/td>\n<\/tr>\n
674<\/td>\nTABLE 1224.4.11 ACCEPTABLE CEILING AND CARPET LOCATIONS <\/td>\n<\/tr>\n
676<\/td>\nTABLE 1224.5 SOUND TRANSMISSION LIMITATIONS IN ACUTE CARE GENERAL HOSPITALS <\/td>\n<\/tr>\n
699<\/td>\nSECTION 1225 [OSHPD 2] SKILLED NURSING AND INTERMEDIATE-CARE FACILITIES <\/td>\n<\/tr>\n
707<\/td>\nSECTION 1226 [OSHPD 3] CLINICS <\/td>\n<\/tr>\n
717<\/td>\nSECTION 1227 [OSHPD 4] CORRECTIONAL TREATMENT CENTERS <\/td>\n<\/tr>\n
722<\/td>\nSECTION 1228 RESERVED
SECTION 1229 RESERVED
SECTION 1230 [BSCC] MINIMUM STANDARDS FOR JUVENILE FACILITIES <\/td>\n<\/tr>\n
724<\/td>\nTABLE 1230A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES <\/td>\n<\/tr>\n
726<\/td>\nSECTION 1231 [BSCC] LOCAL DETENTION <\/td>\n<\/tr>\n
728<\/td>\nTABLE 1231A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES <\/td>\n<\/tr>\n
732<\/td>\nSECTION 1232 RESERVED
SECTION 1233 RESERVED
SECTION 1234 RESERVED
SECTION 1235 [DPH] SANITARY CONTROL OF SHELLFISH (PLANTS AND OPERATIONS) <\/td>\n<\/tr>\n
733<\/td>\nSECTION 1236 [DPH] LABORATORY ANIMAL QUARTERS
SECTION 1237 [DPH] WILD ANIMAL QUARANTINE FACILITIES
SECTION 1238 RESERVED <\/td>\n<\/tr>\n
734<\/td>\nSECTION 1239 RESERVED
SECTION 1240 [AGR] MEAT AND POULTRY PROCESSING PLANTS <\/td>\n<\/tr>\n
735<\/td>\nTABLE 1240.15.1
SECTION 1241 [AGR] COLLECTION CENTERS AND FACILITIES
SECTION 1242 [AGR] RENDERERS <\/td>\n<\/tr>\n
736<\/td>\nSECTION 1243 [AGR] HORSEMEAT AND PET FOOD ESTABLISHMENTS
SECTION 1244 RESERVED
SECTION 1245 RESERVED
SECTION 1246 RESERVED
SECTION 1247 RESERVED
SECTION 1248 RESERVED
SECTION 1249 RESERVED
SECTION 1250 [CA] PHARMACIES <\/td>\n<\/tr>\n
737<\/td>\nSECTION 1251 [CA] VETERINARY FACILITIES
SECTION 1252 [CA] BARBER COLLEGES AND SHOPS <\/td>\n<\/tr>\n
738<\/td>\nSECTION 1253 [CA] SCHOOLS OF COSMETOLOGY, COSMETOLOGICAL ESTABLISHMENTS AND SATELLITE CLASSROOMS
SECTION 1254 [CA] ACUPUNCTURE OFFICES <\/td>\n<\/tr>\n
740<\/td>\nCHAPTER 13 ENERGY EFFICIENCY <\/td>\n<\/tr>\n
742<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 14 \u2013 EXTERIOR WALLS <\/td>\n<\/tr>\n
744<\/td>\nCHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 DEFINITIONS
SECTION 1403 PERFORMANCE REQUIREMENTS <\/td>\n<\/tr>\n
745<\/td>\nSECTION 1404 MATERIALS <\/td>\n<\/tr>\n
746<\/td>\nSECTION 1405 INSTALLATION OF WALL COVERINGS
TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS <\/td>\n<\/tr>\n
747<\/td>\nTABLE 1405.3.1 CLASS III VAPOR RETARDERS <\/td>\n<\/tr>\n
751<\/td>\nSECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
TABLE 1406.2.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS <\/td>\n<\/tr>\n
752<\/td>\nSECTION 1407 METAL COMPOSITE MATERIALS (MCM) <\/td>\n<\/tr>\n
753<\/td>\nTABLE 1407.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS <\/td>\n<\/tr>\n
754<\/td>\nSECTION 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1409 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL) <\/td>\n<\/tr>\n
755<\/td>\nSECTION 1410 [DSA-SS & DSA-SS\/CC, OSHPD 1, 2 & 4] ADDITIONAL REQUIREMENTS FOR ANCHORED AND ADHERED VENEER <\/td>\n<\/tr>\n
758<\/td>\nCALIFORNIA BUILDING CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 15 \u2013 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES <\/td>\n<\/tr>\n
760<\/td>\nCHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 DEFINITIONS
SECTION 1503 WEATHER PROTECTION <\/td>\n<\/tr>\n
761<\/td>\nSECTION 1504 PERFORMANCE REQUIREMENTS
TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION <\/td>\n<\/tr>\n
762<\/td>\nTABLE 1505.1a MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION <\/td>\n<\/tr>\n
763<\/td>\nSECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
TABLE 1507.2.7.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158a <\/td>\n<\/tr>\n
764<\/td>\nTABLE 1507.2.7.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161 <\/td>\n<\/tr>\n
765<\/td>\nTABLE 1507.2.9.2 VALLEY LINING MATERIAL <\/td>\n<\/tr>\n
766<\/td>\nTABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT <\/td>\n<\/tr>\n
767<\/td>\nTABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE <\/td>\n<\/tr>\n
769<\/td>\nTABLE 1507.7.6 SLATE SHINGLE HEADLAP <\/td>\n<\/tr>\n
770<\/td>\nTABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION <\/td>\n<\/tr>\n
771<\/td>\nTABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE <\/td>\n<\/tr>\n
772<\/td>\nTABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE <\/td>\n<\/tr>\n
773<\/td>\nTABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS <\/td>\n<\/tr>\n
774<\/td>\nTABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
SECTION 1508 ROOF INSULATION
TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 ROOFTOP STRUCTURES <\/td>\n<\/tr>\n
777<\/td>\nSECTION 1510 REROOFING
SECTION 1511 SOLAR PHOTOVOLTAIC PANELS\/MODULES
SECTION 1512 [DSA-SS & DSA-SS\/CC, OSHPD 1, 2 & 4] SEISMIC ANCHORAGE OF SLATE SHINGLE, CLAY AND CONCRETE TILE ROOF COVERINGS <\/td>\n<\/tr>\n
780<\/td>\nINDEX <\/td>\n<\/tr>\n
820<\/td>\nHISTORY NOTE APPENDIX <\/td>\n<\/tr>\n
822<\/td>\nGET AHEAD WITH NEW TOOLS FOR YOUR CODE <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

California Building Code, Title 24 Part 2, Volume 1 (W\/ ERRATA & SUPPLEMENT)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
CA<\/b><\/a><\/td>\n2013<\/td>\n823<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":110438,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2720],"product_tag":[],"class_list":{"0":"post-110437","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ca","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/110437","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/110438"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=110437"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=110437"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=110437"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}