{"id":117051,"date":"2024-10-19T03:29:13","date_gmt":"2024-10-19T03:29:13","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-c1295-6\/"},"modified":"2024-10-24T22:30:44","modified_gmt":"2024-10-24T22:30:44","slug":"astm-c1295-6","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-c1295-6\/","title":{"rendered":"ASTM-C1295"},"content":{"rendered":"<\/p>\n
1.1 This test method covers the measurement of gamma energy emitted from fission products in uranium hexafluoride (UF 6 ) and uranyl nitrate solution. It is intended to provide a method for demonstrating compliance with UF 6 specifications C 787 and C 996 and uranyl nitrate specification C 788.<\/p>\n
1.2 The lower limit of detection is 5000 MeV Bq\/kg (MeV\/kg per second) of uranium and is the square root of the sum of the squares of the individual reporting limits of the nuclides to be measured. The limit of detection was determined on a pure, aged natural uranium (ANU) solution. The value is dependent upon detector efficiency and background.<\/p>\n
1.3 The nuclides to be measured are 106<\/sup> Ru\/ 106<\/sup> Rh, 103<\/sup> Ru, 137<\/sup> Cs, 144<\/sup> Ce, 144<\/sup> Pr, 141<\/sup> Ce, 95<\/sup> Zr, 95<\/sup> Nb, and 125<\/sup> Sb. Other gamma energy-emitting fission nuclides present in the spectrum at detectable levels should be identified and quantified as required by the data quality objectives.<\/p>\n 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/p>\n C1295-05 Standard Test Method for Gamma Energy Emission from Fission Products in Uranium Hexafluoride and Uranyl Nitrate Solution<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Summary of Test Method
Significance and Use
Apparatus <\/td>\n<\/tr>\n\n 2<\/td>\n Calibration and Standardization of Detector
Measurement of Control Standard Solution
TABLE 1 <\/td>\n<\/tr>\n\n 3<\/td>\n Procedure
Calculation
Precision and Bias <\/td>\n<\/tr>\n\n 4<\/td>\n Keywords
TABLE 2 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2005<\/td>\n 4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":117053,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[464,2637],"product_tag":[],"class_list":{"0":"post-117051","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-27-120-30","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/117051","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/117053"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=117051"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=117051"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=117051"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}