{"id":136059,"date":"2024-10-19T07:50:51","date_gmt":"2024-10-19T07:50:51","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ca-la-couty-greenbuildingcode-2011\/"},"modified":"2024-10-25T00:01:04","modified_gmt":"2024-10-25T00:01:04","slug":"ca-la-couty-greenbuildingcode-2011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ca\/ca-la-couty-greenbuildingcode-2011\/","title":{"rendered":"CA LA Couty GreenBuildingCode 2011"},"content":{"rendered":"
This package includes 2011 County of Los Angeles Green Building Standards Code Amendment pages, the 2010 California Green Building Standards Code (CALGREEN) (Title 24, Part 11)<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 2011 COUNTY OF LOS ANGELES GREEN BUILDING STANDARDS CODE LOS ANGELES COUNTY CODE TITLE 31 BASED ON THE 2010 CALGreen <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | COUNTY OF LOS ANGELES 2011 GREEN BUILDING STANDARDS CODE ADOPTING BY REFERENCE PORTIONS OF THE 2010 EDITION CALIFORNIA GREEN BUILDING STANDARDS CODE TITLE PAGE <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | COPYRIGHT <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | PREFACE ACKNOWLEDGMENTS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | PREFACE TO THE COUNTY OF LOS ANGELES AMENDMENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | CALIFORNIA CODE OF REGULATIONS, TITLE 24 CALIFORNIA AGENCY INFORMATION CONTACT LIST <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 1 \u2013 ADMINISTRATION CHAPTER 1 ADMINISTRATION SECTION 100 ADOPTION BY REFERENCE SECTION 101 TITLE, PURPOSE AND INTENT <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 2 \u2013 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 3 \u2013 GREEN BUILDING CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL SECTION 302 MIXED OCCUPANCY BUILDINGS SECTION 303 PHASED PROJECTS SECTION 304 VOLUNTARY TIERS <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | SECTION 305 CALGreen TIER 1 AND CALGREEN TIER 2 SECTION 306 VOLUNTARY MEASURES <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 4 \u2013 RESIDENTIAL MANDATORY MEASURES CHAPTER 4 RESIDENTIAL MANDATORY MEASURES DIVISION 4.1 \u2013 PLANNING AND DESIGN SECTION 4.101 GENERAL SECTION 4.102 DEFINITIONS SECTION 4.103 SITE SELECTION (RESERVED) SECTION 4.104 SITE PRESERVATION (RESERVED) SECTION 4.105 DECONSTRUCTION AND REUSE OF EXISTING STRUCTURES (RESERVED) SECTION 4.106 SITE DEVELOPMENT <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | DIVISION 4.2 \u2013 ENERGY EFFICIENCY SECTION 4.201 GENERAL <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | DIVISION 4.3 \u2013WATER EFFICIENCY AND CONSERVATION SECTION 4.301 GENERAL SECTION 4.302 DEFINITIONS SECTION 4.303 INDOOR WATER USE TABLE 4.303.1 WATER USE BASELINE1 <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | TABLE 4.303.2 FIXTURE FLOW RATES TABLE 4.303.3 STANDARDS FOR PLUMBING FIXTURES AND FIXTURE FITTINGS SECTION 4.304 OUTDOOR WATER USE <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | SECTION 4.305 WATER REUSE SYSTEMS (RESERVED) <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | DIVISION 4.4 \u2013 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY SECTION 4.401 GENERAL SECTION 4.402 DEFINITIONS SECTION 4.403 FOUNDATION SYSTEMS (RESERVED) SECTION 4.404 EFFICIENT FRAMING TECHNIQUES (RESERVED) SECTION 4.405 MATERIAL SOURCES (RESERVED) SECTION 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE SECTION 4.407 WATER RESISTANCE AND MOISTURE MANAGEMENT (RESERVED) SECTION 4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING SECTION 4.409 LIFE CYCLE ASSESSMENT (RESERVED) SECTION 4.410 BUILDING MAINTENANCE AND OPERATION <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | DIVISION 4.5 \u2013 ENVIRONMENTAL QUALITY SECTION 4.501 GENERAL SECTION 4.502 DEFINITIONS SECTION 4.503 FIREPLACES SECTION 4.504 POLLUTANT CONTROL <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | TABLE 4.504.1 ADHESIVE VOC LIMIT Less Water and Less Exempt Compounds in Grams per Liter TABLE 4.504.2 SEALANT VOC LIMIT Less Water and Less Exempt Compounds in Grams per Liter <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | TABLE 4.504.3 VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS Grams of VOC per Liter of Coating, Less Water and Less Exempt Compounds TABLE 4.504.5 FORMALDEHYDE LIMITS Maximum Formaldehyde Emissions in Parts per Million SECTION 4.505 INTERIOR MOISTURE CONTROL <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | SECTION 4.506 INDOOR AIR QUALITY AND EXHAUST SECTION 4.507 ENVIRONMENTAL COMFORT SECTION 4.508 OUTDOOR AIR QUALITY (RESERVED) <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | CHAPTER 5 NONRESIDENTIAL MANDATORY MEASURES CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 5 \u2013 NONRESIDENTIAL MANDATORY MEASURES DIVISION 1 \u2013 PLANNING AND DESIGN DIVISION 5.1 \u2013 PLANNING AND DESIGN SECTION 5.101 GENERAL SECTION 5.102 DEFINITIONS SECTION 5.103 SITE SELECTION (RESERVED) SECTION 5.104 SITE PRESERVATION (RESERVED) <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | SECTION 5.105 DECONSTRUCTION AND REUSE OF EXISTING STRUCTURES (RESERVED) SECTION 5.106 SITE DEVELOPMENT TABLE 5.106.5.2 <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 5 \u2013 NONRESIDENTIAL MANDATORY MEASURES DIVISION 5.2 \u2013 ENERGY EFFICIENCY DIVISION 5.2 \u2013 ENERGY EFFICIENCY SECTION 5.201 GENERAL <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 5 \u2013 NONRESIDENTIAL MANDATORY MEASURES DIVISION 5.3 \u2013 WATER EFFICIENCY AND CONSERVATION DIVISION 5.3 \u2013 WATER EFFICIENCY AND CONSERVATION SECTION 5.301 GENERAL SECTION 5.302 DEFINITIONS SECTION 5.303 INDOOR WATER USE <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | TABLE 5.303.2.2 INDOOR WATER USE BASELINE <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | TABLE 5.303.2.3 FIXTURE FLOW RATES TABLE 5.303.6 STANDARDS FOR PLUMBING FIXTURES AND FIXTURE FITTINGS SECTION 5.304 OUTDOOR WATER USE <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | SECTION 5.305 WATER REUSE SYSTEMS (RESERVED) <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 5 \u2013 NONRESIDENTIAL MANDATORY MEASURES DIVISION 5.4 \u2013 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY DIVISION 5.4 \u2013 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY SECTION 5.401 GENERAL SECTION 5.402 DEFINITIONS SECTION 5.403 FOUNDATION SYSTEMS (RESERVED) SECTION 5.404 EFFICIENT FRAMING TECHNIQUES (RESERVED) <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | SECTION 5.405 MATERIAL SOURCES (RESERVED) SECTION 5.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE (RESERVED) SECTION 5.407 WATER RESISTANCE AND MOISTURE MANAGEMENT SECTION 5.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING SECTION 5.409 LIFE CYCLE ASSESSMENT (RESERVED) SECTION 5.410 BUILDING MAINTENANCE AND OPERATION <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 5 \u2013 NONRESIDENTIAL MANDATORY MEASURES DIVISION 5.5 \u2013 ENVIRONMENTAL QUALITY DIVISION 5.5 \u2013 ENVIRONMENTAL QUALITY SECTION 5.501 GENERAL SECTION 5.502 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | SECTION 5.503 FIREPLACES SECTION 5.504 POLLUTANT CONTROL TABLE 5.504.4.1 ADHESIVE VOC LIMIT Less Water and Less Exempt Compounds in Grams Per Liter <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | TABLE 5.504.4.2 SEALANT VOC LIMIT Less Water and Less Exempt Compounds in Grams per Liter TABLE 5.504.4.3 VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS Grams of VOC Per Liter of Coating, Less Water and Less Exempt Compounds <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | TABLE 5.504.4.5 FORMALDEHYDE LIMITS Maximum Formaldehyde Emissions in Parts per Million. SECTION 5.505 INDOOR MOISTURE CONTROL <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | SECTION 5.506 INDOOR AIR QUALITY SECTION 5.507 ENVIRONMENTAL COMFORT SECTION 5.508 OUTDOOR AIR QUALITY <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 6 \u2013 REFERENCED ORGANIZATIONS AND STANDARDS CHAPTER 6 REFERENCED ORGANIZATIONS AND STANDARDS SECTION 601 GENERAL <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | AABC ACCA ANSI ASHRAE ASME ASTM CSA IAPMO NEBB NSF TABB <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 7 \u2013 INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS CHAPTER 7 INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS SECTION 701 GENERAL (RESERVED) SECTION 702 QUALIFICATIONS <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | SECTION 703 VERIFICATIONS <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE CHAPTER 8 \u2013 COMPLIANCE FORMS AND WORKSHEETS <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | CHAPTER 8 COMPLIANCE FORMS AND WORKSHEETS WORKSHEET (WS-1) BASELINE WATER USE <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | WORKSHEET (WS-2) 20 PERCENT REDUCTION WATER USE <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | WORKSHEET (WS-3) 30\u201335 OR 40 PERCENT REDUCTION WATER USE <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | CONSTRUCTION WASTE MANAGEMENT (CWM) PLAN <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | CONSTRUCTION WASTE MANAGEMENT (CWM) WORKSHEET <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | CONSTRUCTION WASTE MANAGEMENT (CWM) ACKNOWLEDGMENT <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE APPENDIX A4 \u2013 RESIDENTIAL VOLUNTARY MEASURES APPENDIX A4 RESIDENTIAL VOLUNTARY MEASURES DIVISION A4.1 \u2013 PLANNING AND DESIGN PREFACE SECTION A4.101 GENERAL SECTION A4.102 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | SECTION A4.103 SITE SELECTION SECTION A4.104 SITE PRESERVATION SECTION A4.105 DECONSTRUCTION AND REUSE OF EXISTING MATERIALS SECTION A4.106 SITE DEVELOPMENT <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | TABLE A4.106.5(1) TIER 1 TABLE A4.106.5(2) TIER 2 <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | SECTION A4.107 INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL CONDITIONS <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | DIVISION A4.2 \u2013 ENERGY EFFICIENCY SECTION A4.201 GENERAL SECTION A4.202 DEFINITIONS (RESERVED) SECTION A4.203 PERFORMANCE APPROACH SECTION A4.204 PRESCRIPTIVE APPROACH (RESERVED) SECTION A4.205 BUILDING ENVELOPE SECTION A4.206 AIR SEALING PACKAGE SECTION A4.207 HVAC DESIGN, EQUIPMENT AND INSTALLATION <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | SECTION A4.208 WATER HEATING DESIGN ,EQUIPMENT AND INSTALLATION SECTION A4.209 LIGHTING SECTION A4.210 APPLIANCES SECTION A4.211 RENEWABLE ENERGY <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | SECTION A4.212 ELEVATORS, ESCALATORS AND OTHER EQUIPMENT (RESERVED) SECTION A4.213 INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL CONDITIONS <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | DIVISION A4.3 \u2013 WATER EFFICIENCY AND CONSERVATION SECTION A4.301 GENERAL (RESERVED) SECTION A4.302 DEFINITIONS SECTION A4.303 INDOOR WATER USE SECTION A4.304 OUTDOOR WATER USE <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | SECTION A4.305 WATER REUSE SYTEMS SECTION A4.306 INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL CONDITIONS <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | DIVISION A4.4 \u2013 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY SECTION A4.401 GENERAL (RESERVED) SECTION A4.402 DEFINITIONS (RESERVED) SECTION A4.403 FOUNDATION SYSTEMS SECTION A4.404 EFFICIENT FRAMING TECHNIQUES SECTION A4.405 MATERIAL SOURCES <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | SECTION A4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE (RESERVED) SECTION A4.407 WATER RESISTANCE AND MOISTURE MANAGEMENT SECTION A4.408 CONSTRUCTION WASTE DISPOSAL REDUCTION, DISPOSAL AND RECYCLING SECTION A4.409 LIFE CYCLE ASSESSMENT (RESERVED) SECTION A4.410 BUILDING MAINTENANCE AND OPERATION (RESERVED) <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | SECTION A4.411 INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL CONDITIONS <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | DIVISION A4.5 \u2013 ENVIRONMENTAL QUALITY SECTION A4.501 GENERAL (RESERVED) SECTION A4.502 DEFINITIONS SECTION A4.503 FIREPLACES (RESERVED) SECTION A4.504 POLLUTANT CONTROL SECTION A4.505 INTERIOR MOISTURE CONTROL (RESERVED) SECTION A4.506 INDOOR AIR QUALITY AND EXHAUST SECTION A4.507 ENVIRONMENTAL COMFORT (RESERVED) SECTION A4.508 OUTDOOR AIR QUALITY (RESERVED) <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | SECTION A4.509 INNOVATIVE CONCEPTS AND LOCAL ENVIRONMENTAL CONDITIONS <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | DIVISION A4.6 \u2013 TIER I AND TIER 2 SECTION A4.601 GENERAL <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST\u2014continued <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST\u2014continued <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST\u2014continued <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST\u2014continued <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST\u2014continued <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST\u2014continued <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST\u2014continued <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST\u2014continued <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST\u2014continued <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST\u2014continued <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | DIVISION A4.7\u2013 RESIDENTIAL MODEL ORDINANCE SAMPLE RESOLUTION FOR ADOPTION OF THE TIER 1 OR TIER 2 PROVISIONS OF THE CALIFORNIA GREEN BUILDING STANDARDS CODE WITH OR WITHOUT ADDITIONAL ITEMS NECESSARY TO ADDRESS INNOVATIVE CONCEPTS OR LOCAL ENVIRONMENTAL CONDITIONS. SAMPLE RESOLUTION ADOPTING THE CALIFORNIA GREEN BUILDING STANDARDS CODE APPENDICES AS A MANDATORY REFERENCE STANDARD <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE APPENDIX A5 \u2013 NONRESIDENTIAL VOLUNTARY MEASURES DIVISION A5.1 \u2013 PLANNING AND DESIGN <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | APPENDIX A5 NONRESIDENTIAL VOLUNTARY MEASURES DIVISION A5.1 \u2013 PLANNING AND DESIGN PREFACE SECTION A5.101 GENERAL SECTION A5.102 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | SECTION A5.103 SITE SELECTION SECTION A5.104 SITE PRESERVATION SECTION A5.105 DECONSTRUCTION AND REUSE OF EXISTING STRUCTURES SECTION A5.106 SITE DEVELOPMENT <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | TABLE A5.106.4.3 <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | TABLE A5.106.5.1.1 TIER 1 10 PERCENT OF TOTAL SPACES [DSA-SS] TABLE A5.106.5.1.2 TIER 2 12 PERCENT OF TOTAL SPACES TABLE A5.106.5.3.1 <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | TABLE A5.106.11.2.1 TIER 1 [BSC] TABLE A5.106.11.2.2 TIER 2 <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE APPENDIX A5 \u2013 NONRESIDENTIAL VOLUNTARY MEASURES DIVISION A5.2 \u2013 ENERGY EFFICIENCY <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | DIVISION A5.2 \u2013 ENERGY EFFICIENCY SECTION A5.201 GENERAL SECTION A5.202 DEFINITIONS SECTION A5.203 PERFORMANCE APPROACH SECTION A5.204 PRESCRIPTIVE APPROACH <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | SECTION A5.205 BUILDING ENVELOPE <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | TABLE A.5.205.1-A DEFAULT FENESTRATION PRODUCT U-FACTORS TABLE A5.205.1-B DEFAULT SOLAR HEAT GAIN COEFFICIENT (SHGC) <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | TABLE A5.205.3-A SLAB INSULATION REQUIREMENTS FOR HEATED SLAB-ON-GRADE <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | TABLE A5.205.3-B MINIMUM PERFORMANCE REQUIREMENTS FOR LIQUID APPLIED ROOF COATINGS SECTION A5.207 HVAC DESIGN, EQUIPMENT AND INSTALLATION <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | TABLE A5.207.1-A ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS\u2014MINIMUM EFFICIENCY REQUIREMENTS TABLE A5.207.1-B UNITARY AND APPLIED HEAT PUMPS\u2014MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | TABLE A5.207.1-C AIR-COOLED GAS-ENGINE HEAT PUMPS TABLE A5.207.1-D WATER CHILLING PACKAGES\u2014MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | TABLE A5.207.1-E PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINAL HEAT PUMPS \u2013 MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | TABLE A5.207.1-G PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | TABLE A5.207.1-H COPS FOR NONSTANDARD CENTRIFUGAL CHILLERS < 150 TONS <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | TABLE A5.207.1- ICOPS FOR NONSTANDARD CENTRIFUGAL CHILLERS > 150 TONS, \u2264 300 TONS <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | TABLE A5.207.1-J COPS FOR NONSTANDARD CENTRIFUGAL CHILLERS > 300 TONS <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | TABLE A5.207.1-K IPLV\/NPLV FOR NONSTANDARD CENTRIFUGAL CHILLERS < 150 TONS <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | TABLE A5.207.1-L IPLV\/NPLV FOR NONSTANDARD CENTRIFUGAL CHILLERS > 150 TONS, < 300 TONS <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | TABLE A5.207.1-M IPLV\/NPLV FOR NONSTANDARD CENTRIFUGAL CHILLERS > 300 TONS <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | EQUATION A5.207.6-A INSULATION THICKNESS EQUATION <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | TABLE A5.207.6-A PIPE INSULATION THICKNESS SECTION A5.209 LIGHTING <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | TABLE A5.209.1-A ULTRASOUND MAXIMUM DECIBEL VALUES <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | TABLE A5.209.4-A GENERAL HARDSCAPE LIGHTING POWER ALLOWANCE <\/td>\n<\/tr>\n | ||||||
135<\/td>\n | TABLE A5.209.4-B ADDITIONAL LIGHTING POWER ALLOWANCE FOR SPECIFIC APPLICATIONS All area and distance measurements in plan view unless otherwise noted <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | TABLE A5.209.4-C ADDITIONAL LIGHTING POWER ALLOWANCE FOR ORDINANCE REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | SECTION A5.210 APPLIANCES SECTION A5.211 RENEWABLE ENERGY <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | SECTION A5.212 ELEVATORS, ESCALATORS AND OTHER EQUIPMENT SECTION A5.213 ENERGY EFFICIENT STEEL FRAMING <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE APPENDIX A5 \u2013 NONRESIDENTIAL VOLUNTARY MEASURES DIVISION A5.3 \u2013 WATER EFFICIENCY AND CONSERVATION <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | DIVISION A5.3 \u2013 WATER EFFICIENCY AND CONSERVATION SECTION A5.301 GENERAL SECTION A5.302 DEFINITIONS SECTION A5.303 INDOOR WATER USE <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | TABLE A5.303.2.2 WATER USE BASELINE TABLE A5.303.2.3.1 FIXTURE FLOW RATES TABLE A5.303.3 COMMERCIAL DISHWASHER WATER USE <\/td>\n<\/tr>\n | ||||||
143<\/td>\n | SECTION A5.304 OUTDOOR WATER USE SECTION A5.305 WATER REUSE (RESERVED) <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE APPENDIX A5 \u2013 NONRESIDENTIAL VOLUNTARY MEASURES DIVISION A5.4 \u2013 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | DIVISION A5.4 \u2013 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY SECTION A5.401 GENERAL SECTION A5.402 DEFINITIONS SECTION A5.403 FOUNDATION SYSTEMS (RESERVED) SECTION A5.404 EFFICIENT FRAMING TECHNIQUES SECTION A5.405 MATERIAL SOURCES <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | EQUATION A5.4-1 <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | SECTION A5.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE SECTION A5.407 WATER RESISTANCE AND MOISTURE MANAGEMENT SECTION A5.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING <\/td>\n<\/tr>\n | ||||||
149<\/td>\n | SECTION A5.409 LIFE CYCLE ASSESSMENT SECTION A5.410 BUILDING MAINTENANCE AND OPERATION <\/td>\n<\/tr>\n | ||||||
151<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE APPENDIX A5 \u2013 NONRESIDENTIAL VOLUNTARY MEASURES DIVISION A5.5 \u2013 ENVIRONMENTAL QUALITY <\/td>\n<\/tr>\n | ||||||
152<\/td>\n | DIVISION A5.5 \u2013 ENVIRONMENTAL QUALITY SECTION A5.501 GENERAL SECTION A5.502 DEFINITIONS SECTION A5.504 POLLUTANT CONTROL <\/td>\n<\/tr>\n | ||||||
155<\/td>\n | TABLE A5.504.8.1 ADHESIVE VOC LIMIT Less Water and Less Exempt Compounds in Grams per Liter TABLE A5.504.8.2 SEALANT VOC LIMIT Less Water and Less Exempt Compounds in Grams per Liter <\/td>\n<\/tr>\n | ||||||
156<\/td>\n | TABLE A5.504.8.3 VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS Grams of VOC Per Liter of Coating, Less Water and Less Exempt Compounds TABLE A5.504.8.5 FORMALDEHYDE LIMITS Maximum formaldehyde emissions in parts per million. SECTION A5.505 INDOOR MOISTURE CONTROL <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | SECTION A5.507 ENVIRONMENTAL COMFORT SECTION A5.508 OUTDOOR AIR QUALITY <\/td>\n<\/tr>\n | ||||||
159<\/td>\n | CALIFORNIA GREEN BUILDING STANDARDS CODE \u2013 MATRIX ADOPTION TABLE APPENDIX A5 \u2013 NONRESIDENTIAL VOLUNTARY MEASURES DIVISION A5.6 \u2013 VOLUNTARY TIERS DIVISION A5.6 \u2013 VOLUNTARY TIERS SECTION A5.601 CALGreen TIER 1 AND TIER 2 <\/td>\n<\/tr>\n | ||||||
162<\/td>\n | DIVISION A5.7 \u2013 NONRESIDENTIAL CHECKLISTS APPLICATION CHECKLIST FOR BSC <\/td>\n<\/tr>\n | ||||||
173<\/td>\n | APPLICATION CHECKLIST DSA-SS <\/td>\n<\/tr>\n | ||||||
183<\/td>\n | NONRESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST [OSHPD 1, 2 and 4] <\/td>\n<\/tr>\n | ||||||
188<\/td>\n | INDEX <\/td>\n<\/tr>\n | ||||||
192<\/td>\n | HISTORY NOTE APPENDIX CALIFORNIA GREEN BUILDING STANDARDS CODE <\/td>\n<\/tr>\n | ||||||
193<\/td>\n | HELPFUL LINKS <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | ICC MEMBERSHIP <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | NEW GUIDELINES FOR GOING GREEN <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" County of Los Angeles Green Building Standards Code Complete Code<\/b><\/p>\n |