{"id":175888,"date":"2024-10-19T10:54:08","date_gmt":"2024-10-19T10:54:08","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ashrae-55-2017\/"},"modified":"2024-10-25T03:08:28","modified_gmt":"2024-10-25T03:08:28","slug":"ashrae-55-2017","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ashrae\/ashrae-55-2017\/","title":{"rendered":"ASHRAE 55 2017"},"content":{"rendered":"

Standard 55 specifies conditions for acceptable thermal environments and is intended for use in design, operation, and commissioning of buildings and other occupied spaces. The 2017 edition of ANSI\/ASHRAE Standard 55 incorporates seven published addenda to the 2013 edition, and provides three compliance methods: a graphic method for simple situations, an analytical method for more general cases and a method that uses elevated air speed to provide comfort. The standard has a separate method for determining acceptable thermal conditions in occupant-controlled naturally conditioned spaces. Given the widespread and easy accessibility of computing power and third-party implementations of the analytical method, it is expected that more users will favor the comprehensive analytical methods over the graphical method. Since 2013, Standard 55 has been rewritten with a renewed focus on application of the standard by practitioners and use of clear, enforceable language. Requirements are now clearly stated and calculation procedures appear sequentially. For example, during design, a “representative occupant” must be defined, and the air speed and temperature they experience must be an average across the human body at three typical measurement heights. All informative background information has been moved to informative appendices. Other noteworthy additions to the standard include clarification of the three comfort calculation approaches in the elevated air speed section; simplification of Appendix A to a single procedure for calculating operative temperature; an update to the scope to ensure the standard isn\u2019t used to override health, safety, and critical process requirements; a new requirement for calculating change to thermal comfort resulting from direct solar radiation; and removal of permissive language throughout the standard. Documentation requirements to show that a design complies with Standard 55 are contained in Section 6, and a sample compliance form is provided in Appendix K. Both of these sections are clarified and streamlined for use by owners and third-party rating systems.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nANSI\/ASHRAE Standard 55-2017 <\/td>\n<\/tr>\n
3<\/td>\nCONTENTS <\/td>\n<\/tr>\n
4<\/td>\nFOREWORD
1. PURPOSE
2. SCOPE
3. DEFINITIONS <\/td>\n<\/tr>\n
6<\/td>\n4. GENERAL REQUIREMENTS
5. CONDITIONS THAT PROVIDE THERMAL COMFORT <\/td>\n<\/tr>\n
16<\/td>\n6. DESIGN COMPLIANCE <\/td>\n<\/tr>\n
17<\/td>\n7. EVALUATION OF COMFORT IN EXISTING BUILDINGS <\/td>\n<\/tr>\n
20<\/td>\n8. REFERENCES <\/td>\n<\/tr>\n
21<\/td>\nNORMATIVE APPENDIX A\u2014METHODS FOR DETERMINING OPERATIVE TEMPERATURE <\/td>\n<\/tr>\n
22<\/td>\nNORMATIVE APPENDIX B\u2014COMPUTER PROGRAM FOR CALCULATION OF PMV-PPD <\/td>\n<\/tr>\n
24<\/td>\nNORMATIVE APPENDIX C\u2014PROCEDURE FOR CALCULATING COMFORT IMPACT OF SOLAR GAIN ON OCCUPANTS <\/td>\n<\/tr>\n
32<\/td>\nNORMATIVE APPENDIX D\u2014PROCEDURE FOR EVALUATING COOLING EFFECT OF ELEVATED AIR SPEED USING SET <\/td>\n<\/tr>\n
37<\/td>\nINFORMATIVE APPENDIX E\u2014CONDITIONS THAT PROVIDE THERMAL COMFORT <\/td>\n<\/tr>\n
38<\/td>\nINFORMATIVE APPENDIX F\u2014USE OF METABOLIC DATA <\/td>\n<\/tr>\n
39<\/td>\nINFORMATIVE APPENDIX G\u2014CLOTHING INSULATION <\/td>\n<\/tr>\n
41<\/td>\nINFORMATIVE APPENDIX H\u2014COMFORT ZONE METHODS <\/td>\n<\/tr>\n
43<\/td>\nINFORMATIVE APPENDIX I\u2014LOCAL DISCOMFORT AND VARIATIONS WITH TIME <\/td>\n<\/tr>\n
46<\/td>\nINFORMATIVE APPENDIX J\u2014OCCUPANT-CONTROLLED NATURALLY CONDITIONED SPACES <\/td>\n<\/tr>\n
48<\/td>\nINFORMATIVE APPENDIX K\u2014SAMPLE DESIGN COMPLIANCE DOCUMENTATION <\/td>\n<\/tr>\n
51<\/td>\nINFORMATIVE APPENDIX L\u2014MEASUREMENTS, SURVEYS, AND EVALUATION OF COMFORT IN EXISTING SPACES: PARTS 1 AND 2 <\/td>\n<\/tr>\n
58<\/td>\nINFORMATIVE APPENDIX M\u2014BIBLIOGRAPHY AND INFORMATIVE REFERENCES <\/td>\n<\/tr>\n
61<\/td>\nINFORMATIVE APPENDIX N\u2014ADDENDA DESCRIPTION <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASHRAE Standard 55-2017 – Thermal Environmental Conditions for Human Occupancy (ANSI\/ASHRAE Approved)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASHRAE<\/b><\/a><\/td>\n2017<\/td>\n66<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":175892,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2719],"product_tag":[],"class_list":{"0":"post-175888","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ashrae","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/175888","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/175892"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=175888"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=175888"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=175888"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}