{"id":17794,"date":"2024-10-16T22:28:35","date_gmt":"2024-10-16T22:28:35","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e694-2010\/"},"modified":"2024-10-24T12:33:50","modified_gmt":"2024-10-24T12:33:50","slug":"astm-e694-2010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e694-2010\/","title":{"rendered":"ASTM-E694 2010"},"content":{"rendered":"

ASTM E694-99-Reapproved2010<\/h3>\n

Historical Standard: Standard Specification for Laboratory Glass Volumetric Apparatus<\/h4>\n
\n

ASTM E694<\/h4>\n

Scope<\/strong><\/p>\n

1.1 This specification covers general requirements common to glass volumetric apparatus. Specific dimensions and tolerances for applicable instruments are given in other specifications as cited throughout this specification. Glass must conform to Specifications E438 and be calibrated in accordance with Practice E542.<\/p>\n

1.1.1 Class A<\/span>\u2014<\/span>Each instrument shall be marked with the letter A<\/span> to signify compliance with applicable construction and accuracy requirements. Instruments may be marked with an identification marker (serial number) at the option of the manufacturer.<\/p>\n

1.1.2 Class B<\/span>\u2014<\/span>General purpose instruments are of the same basic design as Class A. However, volumetric tolerances for Class B instruments shall be within twice the specified range allowed for Class A unless otherwise specified.<\/p>\n

Keywords<\/strong><\/p>\n

apparatus; glass; laboratory; volumetric; Cylinders; Burets (laboratory)–specifications; Flasks (laboratory)–specifications; Glass laboratory apparatus–specifications; Graduated laboratory apparatus–specifications; Laboratory apparatus–specifications; Laboratory volumetric apparatus; Volumetric laboratory apparatus<\/p>\n

ICS Code<\/strong><\/p>\n

ICS Number Code 71.040.20 (Laboratory ware and related apparatus)<\/p>\n

DOI:<\/strong> 10.1520\/E0694-99R10<\/p>\n<\/div>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
General Requirements <\/td>\n<\/tr>\n
2<\/td>\nFIG. 1 <\/td>\n<\/tr>\n
3<\/td>\nFIG. 2 <\/td>\n<\/tr>\n
4<\/td>\nSpecial Requirements
FIG. 3
FIG. 4 <\/td>\n<\/tr>\n
5<\/td>\nKeywords
A1. LIMIT OF VOLUMETRIC ERROR IN RELATION TO DIAMETER AT THE MENISCUS
A1.1
A1.2
A1.3
A1.4
A1.5
A1.6 <\/td>\n<\/tr>\n
6<\/td>\nA1.7
A1.8
TABLE A1.1 <\/td>\n<\/tr>\n
7<\/td>\nFIG. A1.1 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

E694-99(2010) Standard Specification for Laboratory Glass Volumetric Apparatus<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2010<\/td>\n7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":17795,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[998,2637],"product_tag":[],"class_list":{"0":"post-17794","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-71-040-20","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/17794","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/17795"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=17794"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=17794"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=17794"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}