{"id":202410,"date":"2024-10-19T12:56:39","date_gmt":"2024-10-19T12:56:39","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ny-stateexistingbuildingcode-2020-temp\/"},"modified":"2024-10-25T05:34:42","modified_gmt":"2024-10-25T05:34:42","slug":"ny-stateexistingbuildingcode-2020-temp","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ny\/ny-stateexistingbuildingcode-2020-temp\/","title":{"rendered":"NY StateExistingBuildingCode 2020 TEMP"},"content":{"rendered":"

This is a fully integrated custom code based on the 2018 International Existing Building Code.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nCover <\/td>\n<\/tr>\n
2<\/td>\nCopyright <\/td>\n<\/tr>\n
3<\/td>\nACKNOWLEDGEMENTS <\/td>\n<\/tr>\n
5<\/td>\nPREFACE <\/td>\n<\/tr>\n
7<\/td>\nEFFECTIVE USE <\/td>\n<\/tr>\n
13<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
17<\/td>\nCHAPTER 1 SCOPE AND ADMINISTRATION
Section
\n 101 Title, Scope and Purpose <\/td>\n<\/tr>\n
18<\/td>\n102 Applicability <\/td>\n<\/tr>\n
19<\/td>\n103 Administration and Enforcement <\/td>\n<\/tr>\n
20<\/td>\n104 Materials, Equipment and
\n Methods of Construction
105 Building Permits, Construction Inspections,
\n Stop Work Orders, Certificates of Occupancy,
\n and Operating Permits <\/td>\n<\/tr>\n
22<\/td>\n106 Submittal Documents <\/td>\n<\/tr>\n
23<\/td>\n107 Service Utilities
108 Inspection of Solid Fuel-burning
\n Heating Appliances, Chimneys and Flues <\/td>\n<\/tr>\n
25<\/td>\nCHAPTER 2 DEFINITIONS
Section
\n 201 General
202 General Definitions <\/td>\n<\/tr>\n
29<\/td>\nCHAPTER 3 PROVISIONS FOR ALL
\n COMPLIANCE METHODS
Section
\n 301 Administration
302 General Provisions
303 Structural Design Loads and Evaluation
\n and Design Procedures <\/td>\n<\/tr>\n
30<\/td>\n304 In-Situ Load Tests
305 Accessibility for Existing Buildings <\/td>\n<\/tr>\n
33<\/td>\n306 Energy Storage Systems <\/td>\n<\/tr>\n
35<\/td>\nCHAPTER 4 REPAIRS
Section
\n 401 General
402 Building Elements and Materials
403 Fire Protection
404 Means of Egress
405 Structural <\/td>\n<\/tr>\n
36<\/td>\n406 Electrical
407 Mechanical
408 Plumbing <\/td>\n<\/tr>\n
37<\/td>\nCHAPTER 5 PRESCRIPTIVE
\n COMPLIANCE METHOD
Section
\n 501 General
502 Additions <\/td>\n<\/tr>\n
38<\/td>\n503 Alterations <\/td>\n<\/tr>\n
40<\/td>\n504 Fire Escapes <\/td>\n<\/tr>\n
41<\/td>\n505 Windows and Emergency Escape Openings <\/td>\n<\/tr>\n
42<\/td>\n506 Change of Occupancy <\/td>\n<\/tr>\n
43<\/td>\n507 Historic Buildings <\/td>\n<\/tr>\n
45<\/td>\nCHAPTER 6 CLASSIFICATION OF WORK
Section
\n 601 General
602 Alteration\u2014Level 1
603 Alteration\u2014Level 2
604 Alteration\u2014Level 3
605 Change of Occupancy
606 Additions
607 Historic Buildings
608 Relocated Buildings <\/td>\n<\/tr>\n
47<\/td>\nCHAPTER 7 ALTERATIONS\u2014LEVEL 1
Section
\n 701 General
702 Building Elements and Materials <\/td>\n<\/tr>\n
48<\/td>\n703 Fire Protection
704 Means of Egress
705 Reroofing <\/td>\n<\/tr>\n
49<\/td>\n706 Structural
707 Energy Conservation
708 Plumbing <\/td>\n<\/tr>\n
51<\/td>\nCHAPTER 8 ALTERATIONS\u2014LEVEL 2
Section
\n 801 General
802 Building Elements and Materials <\/td>\n<\/tr>\n
53<\/td>\n803 Fire Protection <\/td>\n<\/tr>\n
55<\/td>\n804 Carbon Monoxide Detection
805 Means of Egress <\/td>\n<\/tr>\n
60<\/td>\n806 Structural <\/td>\n<\/tr>\n
61<\/td>\n808 Mechanical
809 Plumbing <\/td>\n<\/tr>\n
62<\/td>\n810 Energy Conservation <\/td>\n<\/tr>\n
63<\/td>\nCHAPTER 9 ALTERATIONS\u2014LEVEL 3
Section
\n 901 General
902 Special Use and Occupancy
903 Building Elements and Materials
904 Fire Protection <\/td>\n<\/tr>\n
64<\/td>\n905 Means of Egress
906 Structural <\/td>\n<\/tr>\n
65<\/td>\n907 Energy Conservation <\/td>\n<\/tr>\n
67<\/td>\nCHAPTER 10 CHANGE OF OCCUPANCY
Section
\n 1001 General
1002 Special Use and Occupancy
1003 Building Elements and Materials
1004 Fire Protection
1005 Means of Egress
1006 Structural <\/td>\n<\/tr>\n
68<\/td>\n1007 Electrical
1008 Mechanical
1009 Plumbing <\/td>\n<\/tr>\n
69<\/td>\n1010 Other Requirements
1011 Change of Occupancy Classification <\/td>\n<\/tr>\n
73<\/td>\nCHAPTER 11 ADDITIONS
Section
\n 1101 General
1102 Heights and Areas
1103 Structural <\/td>\n<\/tr>\n
74<\/td>\n1104 Smoke Alarms in Occupancy
\n Groups R and I-1
1105 Carbon Monoxide Detection
1106 Storm Shelters
1107 Energy Conservation <\/td>\n<\/tr>\n
75<\/td>\nCHAPTER 12 HISTORIC BUILDINGS
Section
\n 1201 General
1202 Repairs
1203 Fire Safety <\/td>\n<\/tr>\n
76<\/td>\n1204 Change of Occupancy <\/td>\n<\/tr>\n
77<\/td>\n1205 Structural
1206 Relocated Buildings <\/td>\n<\/tr>\n
79<\/td>\nCHAPTER 13 PERFORMANCE
\n COMPLIANCE METHODS
Section
\n 1301 General <\/td>\n<\/tr>\n
91<\/td>\nCHAPTER 14 RELOCATED OR
\n MOVED BUILDINGS
Section
\n 1401 General
1402 Requirements <\/td>\n<\/tr>\n
93<\/td>\nCHAPTER 15 CONSTRUCTION
\n SAFEGUARDS
Section
\n 1501 General <\/td>\n<\/tr>\n
94<\/td>\n1502 Protection of Adjoining Property
1503 Temporary Use of Streets,
\n Alleys and Public Property <\/td>\n<\/tr>\n
95<\/td>\n1504 Fire Extinguishers
1505 Means of Egress
1506 Standpipes
1507 Automatic Sprinkler System
1508 Accessibility
1509 Water Supply for Fire Protection <\/td>\n<\/tr>\n
97<\/td>\nCHAPTER 16 REFERENCED STANDARDS <\/td>\n<\/tr>\n
101<\/td>\nAPPENDIX A GUIDELINES FOR
\n THE SEISMIC RETROFIT
\n OF EXISTING BUILDINGS
CHAPTER A1 SEISMIC STRENGTHENING
\n PROVISIONS FOR UNREINFORCED
\n MASONRY BEARING WALL
\n BUILDINGS
Section
\n A101 Purpose
A102 Scope
A103 Definitions <\/td>\n<\/tr>\n
102<\/td>\nA104 Symbols and Notations
A105 General Requirements <\/td>\n<\/tr>\n
103<\/td>\nA106 Materials Requirements <\/td>\n<\/tr>\n
105<\/td>\nA107 Quality Control
A108 Design Strengths <\/td>\n<\/tr>\n
106<\/td>\nA109 Analysis and Design Procedure
A110 General Procedure
A111 Special Procedure <\/td>\n<\/tr>\n
108<\/td>\nA112 Analysis and Design <\/td>\n<\/tr>\n
109<\/td>\nA113 Detailed Building System
\n Design Requirements <\/td>\n<\/tr>\n
110<\/td>\nA114 Walls of Unburned Clay,
\n Adobe or Stone Masonry <\/td>\n<\/tr>\n
117<\/td>\nCHAPTER A2 EARTHQUAKE HAZARD
\n REDUCTION IN EXISTING
\n REINFORCED CONCRETE AND
\n REINFORCED MASONRY WALL
\n BUILDINGS WITH FLEXIBLE
\n DIAPHRAGMS
Section
\n A201 Purpose
A202 Scope
A203 Definitions
A204 Symbols and Notations
A205 General Requirements <\/td>\n<\/tr>\n
118<\/td>\nA206 Analysis and Design <\/td>\n<\/tr>\n
119<\/td>\nA207 Materials of Construction <\/td>\n<\/tr>\n
121<\/td>\nCHAPTER A3 PRESCRIPTIVE PROVISIONS
\n FOR SEISMIC STRENGTHENING
\n OF CRIPPLE WALLS AND
\n SILL PLATE ANCHORAGE
\n OF LIGHT, WOOD-FRAME
\n RESIDENTIAL BUILDINGS
Section
\n A301 General
A302 Definitions <\/td>\n<\/tr>\n
122<\/td>\nA303 Structural Weaknesses
A304 Strengthening Requirements <\/td>\n<\/tr>\n
139<\/td>\nCHAPTER A4 EARTHQUAKE RISK
\n REDUCTION IN WOOD-FRAME
\n RESIDENTIAL BUILDINGS
\n WITH SOFT, WEAK OR
\n OPEN FRONT WALLS
Section
\n A401 General
A402 Definitions
A403 Analysis and Design <\/td>\n<\/tr>\n
141<\/td>\nA404 Prescriptive Measures for Weak Story
A405 Materials of Construction <\/td>\n<\/tr>\n
142<\/td>\nA406 Information Required to be on the Plans
A407 Quality Control <\/td>\n<\/tr>\n
143<\/td>\nCHAPTER A5 REFERENCED STANDARDS <\/td>\n<\/tr>\n
145<\/td>\nAPPENDIX B SUPPLEMENTARY
\n ACCESSIBILITY REQUIREMENTS
\n FOR EXISTING BUILDINGS
\n AND FACILITIES
Section
\n B101 Qualified Historical Buildings and Facilities
B102 Fixed Transportation Facilities and Stations <\/td>\n<\/tr>\n
146<\/td>\nB103 Dwelling Units and Sleeping Units
B104 Referenced Standards <\/td>\n<\/tr>\n
147<\/td>\nAPPENDIX C GUIDELINES FOR THE
\n WIND RETROFIT OF
\n EXISTING BUILDINGS
CHAPTER C1 GABLE END RETROFIT
\n FOR HIGH-WIND AREAS
Section
\n C101 General
C102 Definitions
C103 Materials of Construction <\/td>\n<\/tr>\n
149<\/td>\nC104 Retrofitting Gable End Walls
\n to Enhance Wind Resistance <\/td>\n<\/tr>\n
169<\/td>\nCHAPTER C2 ROOF DECK FASTENING
\n FOR HIGH-WIND AREAS
Section
\n C201 General
C202 Roof Deck Attachment for Wood Roofs
C203 Referenced Standards <\/td>\n<\/tr>\n
171<\/td>\nAPPENDIX D DIAPER CHANGING
\n STATIONS
D101 Introduction
D102 Purpose
D103 Definitions <\/td>\n<\/tr>\n
172<\/td>\nD104 General Requirements <\/td>\n<\/tr>\n
173<\/td>\nD105 Accessibility, Construction and Installation
\n Requirements
D16 Signage
D107 Maintenance
D108 Historic Buildings <\/td>\n<\/tr>\n
189<\/td>\nResource A Table of Contents <\/td>\n<\/tr>\n
308<\/td>\nBibliography <\/td>\n<\/tr>\n
315<\/td>\nINDEX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Existing Building Code of New York State<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NY<\/b><\/a><\/td>\n2020<\/td>\n322<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":202414,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2744],"product_tag":[],"class_list":{"0":"post-202410","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ny","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/202410","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/202414"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=202410"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=202410"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=202410"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}