{"id":202506,"date":"2024-10-19T12:57:10","date_gmt":"2024-10-19T12:57:10","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/aci-506-2-2013-ra2018\/"},"modified":"2024-10-25T05:35:02","modified_gmt":"2024-10-25T05:35:02","slug":"aci-506-2-2013-ra2018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/aci\/aci-506-2-2013-ra2018\/","title":{"rendered":"ACI 506.2 2013 RA2018"},"content":{"rendered":"
This specification contains the construction requirements for the application of shotcrete. Both wet- and dry-mixture shotcrete are addressed, as well as fiber-reinforced shotcrete. The minimum standard for materials, properties, testing, and application are covered. The materials, processes, quality control measures, and inspections described in this specification should be tested, monitored, or performed as applicable only by individuals holding the appropriate ACI certifications or equivalent. Keywords: dry-mixture shotcrete; fiber-reinforced shotcrete; nozzleman; qualification; quality control; quality assurance; shooting; wet-mixture shotcrete.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
3<\/td>\n | TITLE PAGE <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | PART 1\u2014GENERAL 1.1\u2014Scope 1.2\u2014Definitions 1.3\u2014Referenced standards <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | 1.4\u2014Submittals <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | 1.5\u2014Preconstruction testing by Contractor 1.6\u2014Testing during construction <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1.7\u2014Acceptance of Work PART 2\u2014PRODUCTS 2.1\u2014Materials <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 2.2\u2014Packaged shotcrete materials 2.3\u2014Fiber-reinforced shotcrete 2.4\u2014Shotcrete properties 2.5\u2014Proportioning 2.6\u2014Batching, mixing, and delivery PART 3\u2014EXECUTION 3.1\u2014Preparation of surface to receive shotcrete 3.2\u2014Joints <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 3.3\u2014Alignment control 3.4\u2014Application <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3.5\u2014Finish 3.6\u2014Curing 3.7\u2014Protection 3.8\u2014Tolerances 3.9\u2014Repair of shotcrete (nonmandatory portion follows) NOTES TO SPECIFIER General notes <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | FOREWORD TO CHECKLISTS <\/td>\n<\/tr>\n | ||||||