{"id":226053,"date":"2024-10-19T14:41:25","date_gmt":"2024-10-19T14:41:25","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-62756-12015\/"},"modified":"2024-10-25T08:35:49","modified_gmt":"2024-10-25T08:35:49","slug":"bs-en-62756-12015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-62756-12015\/","title":{"rendered":"BS EN 62756-1:2015"},"content":{"rendered":"
IEC 62756-1:2015 specifies a protocol, electrical interface and test procedures for control of electronic lighting equipment by digital signals over the load side mains wiring. Safety requirements are not covered by this standard.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4 General description 4.1 General 4.2 Master-slave structure 4.3 Specification overview 5 General requirements 5.1 Voltage rating <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.2 Frequency rating 5.3 Marking of control devices and control gear 6 Electrical specification 6.1 General <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.2 Wiring method 6.3 Wiring diagram 6.4 Block diagram of the control gear Figures Figure 1 \u2013 Example wiring diagram <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.5 Block diagram of the control device 6.6 Electrical characteristics in different periods of the mains waveform 6.6.1 General Figure 2 \u2013 Example of block diagram of control gear Figure 3 \u2013 Example of block diagram of control device <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.6.2 Separation of the half-wave into time periods 6.6.3 Electrical characteristics of the supply period Figure 4 \u2013 Time periods of each half-wave <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Figure 5 \u2013 Timing of supply period <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Tables Table 1 \u2013 Nominal mains voltage 100\u00a0V, frequency 50\u00a0Hz or 60\u00a0Hz Table 2 \u2013 Nominal mains voltage 120 V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Table 3 \u2013 Nominal mains voltage 200\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz Table 4 \u2013 Nominal mains voltage 230\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.6.4 Electrical characteristics of the operating period 6.6.5 Electrical characteristics of the data period Table 5 \u2013 Nominal mains voltage 277\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Figure\u00a06 \u2013 Timing data period <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Table 6 \u2013 Nominal mains voltage 100\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz Table 7 \u2013 Nominal mains voltage 120 V; frequency 50\u00a0Hz or 60\u00a0Hz Table 8 \u2013 Nominal mains voltage 200\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Table 9 \u2013 Nominal mains voltage 230\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz Table 10 \u2013 Nominal mains voltage 277\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 6.7 Data signal voltage range and timing 6.8 Power up timing Figure 7 \u2013 Rise time and fall time at the control interface Table 11 \u2013 Electrical characteristics of the data signal <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 6.9 Electrical characteristics during the off state of control gear 6.9.1 General 6.9.2 Power controlled off state Table 12 \u2013 Currents and Voltages for control gear during the power controlled off state <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 6.9.3 Telegram controlled off state 7 Data timing 7.1 General 7.2 Information bit timing 7.3 Permissible frames Figure 8 \u2013 Transmission of \u201cstart of telegram\u201d Figure 9 \u2013 Transmission of first bit 0, second bit 0 <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 8 Telegram structure 8.1 General Figure 10 \u2013 Transmission of first bit 0, second bit 1 Figure 11 \u2013 Transmission of first bit 1, second bit 0 Figure 12 \u2013 Transmission of first bit 1, second bit 1 <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 8.2 Telegrams 8.2.1 General 8.2.2 Group number 8.2.3 Telegram type 8.2.4 Parity bit 8.2.5 Data for control of the control gear 9 Definition of telegram types 9.1 Summary of telegram types <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 9.2 Telegram type 0: Brightness 9.3 Telegram type 1: Colour control Figure 13 \u2013 Brightness telegram Figure 14 \u2013 Colour control telegram Table 13 \u2013 Telegram types <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 9.4 Telegram type 2: Colour temperature control 9.5 Telegram type 3 9.6 Telegram type 4 9.7 Telegram type 5: commissioning: Group number assignment Figure 15 \u2013 Colour temperature telegram Figure 16 \u2013 Group number assignment telegram <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 9.8 Telegram type 6: Manufacturer specific 9.9 Telegram type 7: extended telegram 10 Method of operation 10.1 General Figure 17 \u2013 Manufacturer specific telegram <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 10.2 Brightness 10.2.1 General 10.2.2 Response time 10.2.3 Light output level 10.2.4 Start-up 10.3 Colour control 10.3.1 General 10.3.2 Colour (x, y) Table 14 \u2013 Dimming characteristic <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 10.3.3 Response time 10.3.4 Colour gamut 10.3.5 Start-up Figure 18 \u2013 The CIE 1931 colour space chromaticity diagram <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 10.4 Colour temperature control 10.4.1 General 10.4.2 CCT (correlated colour temperature) 10.4.3 Response time 10.4.4 Start-up 10.5 Telegram controlled group number assignment <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 10.6 Manufacturer specific telegram 11 Test procedures 11.1 General <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 11.2 Electrical characteristics tests 11.2.1 General 11.2.2 Test of control device Figure 19 \u2013 Test Circuit for testing the Control Device Table 15 \u2013 Parameters for testing purposes <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 11.2.3 Test of control gear Figure 20 \u2013 Test Circuit for testing the Control Gear <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Figure 21 \u2013 Voltage applied to control gear for test procedure <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 11.3 Test of data timing 11.4 Test of telegram structure 11.4.1 Test of control device 11.4.2 Test of control gear <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 11.5 Test of telegram types 11.5.1 General 11.5.2 Rejection of unsupported telegram types 11.5.3 Test of telegram type 0: brightness 11.5.4 Test of telegram type 1: colour control <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 11.5.5 Test of telegram type 2: colour temperature control 11.5.6 Test of telegram type 5: commissioning 11.5.7 Test of telegram type 6: manufacturer specific 11.6 Test of method of operation 11.6.1 General 11.6.2 Group number operation <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Table 16 \u2013 Group number test telegram sequence <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Annex A (informative) Examples of procedures for telegram controlled group number commissioning A.1 Telegram controlled group number assignment of a new system A.2 Telegram controlled group number assignment of replacement control gear <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | A.3 Telegram controlled changing of group numbers <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Digital load side transmission lighting control – Basic requirements<\/b><\/p>\n |