{"id":229325,"date":"2024-10-19T14:55:07","date_gmt":"2024-10-19T14:55:07","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-tr-60728-3-22016\/"},"modified":"2024-10-25T09:03:29","modified_gmt":"2024-10-25T09:03:29","slug":"bsi-pd-iec-tr-60728-3-22016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-tr-60728-3-22016\/","title":{"rendered":"BSI PD IEC\/TR 60728-3-2:2016"},"content":{"rendered":"
This part of IEC 60728 is applicable to the measurement of 5th<\/sup> order non-linearity for active electronic equipment which carries only digitally modulated television signals, sound signals and signals for interactive services. This method of measurement is specifically applicable to MATV installations but could be applied to broadband and channel selective amplifiers used in all kinds of cable networks.<\/p>\n NOTE 1 The methods of measurement of non-linearity (intermodulation products) applicable to active equipment, when loaded with analogue signals, considered that third order intermodulation products were the most important ones. The new era of television digital signals, transmitted according to DVB-S\/S2, DVB-C\/C2 and DVB-T\/T2 modulation formats, has shown that the non-linear distortions (intermodulation products) in active equipment, when loaded with digital signals, are significant up to the 5th<\/sup> order.<\/p>\n<\/blockquote>\n NOTE 2 With this method of measurement it is possible to obtain information on non-linear distortions (intermodulation products) up to the 5th<\/sup> order in active wideband equipment, using only 5 carriers, placed in an appropriate and suitable way in the equipment bandwidth. Moreover, with this method of measurement it is possible to obtain information on non-linear distortions (up to the 5th<\/sup> order) in narrowband equipment (channel amplifiers and channel frequency converters) carrying DVB-C\/C2 and\/or DVB-T\/T2 signals.<\/p>\n<\/blockquote>\n Cable networks for television signals, sound signals and interactive services – Method of measurement of 5th order non-linearity for active electronic equipment using five carriers<\/b><\/p>\n\n
\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 4<\/td>\n CONTENTS <\/td>\n<\/tr>\n \n 6<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 8<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 9<\/td>\n 1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviated terms
3.1 Terms and definitions <\/td>\n<\/tr>\n\n 11<\/td>\n 3.2 Symbols
3.3 Abbreviated terms <\/td>\n<\/tr>\n\n 12<\/td>\n 4 Method of measurement of 5th order non-linearity for active electronic equipment using five carriers
4.1 General <\/td>\n<\/tr>\n\n 13<\/td>\n 4.2 Equipment required
4.3 Connection of the equipment
4.4 Measurement procedure for 3rd order and 5th order intermodulation products
Figures
Figure\u00a01 \u2013 Measurement configuration with 5 carriers <\/td>\n<\/tr>\n\n 14<\/td>\n Figure\u00a02 \u2013 The five carriers equally spaced at distance D and the intermodulation products <\/td>\n<\/tr>\n \n 15<\/td>\n 4.5 Measurement procedure for 2nd order intermodulation products
4.6 Presentation of the results <\/td>\n<\/tr>\n\n 16<\/td>\n 4.7 Estimated maximum usable output level with a higher number of channels
4.8 Setting of the 5 carriers frequencies for narrow-band equipment
5 Equipment characteristics required to be published <\/td>\n<\/tr>\n\n 17<\/td>\n 6 Example of measurement results
Figure\u00a03 \u2013 Example of measurement results using the measuring method with 5 carriers <\/td>\n<\/tr>\n\n 18<\/td>\n Annex A (informative) Examples of measurement frequencies for channel spacing of 7 MHz and 8 MHz
A.1 Wide-band equipment
A.1.1 General
A.1.2 Operating frequency range: VHF
A.1.3 Operating frequency range: UHF
Tables
Table\u00a0A.1 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in VHF \u2013 Band III
Table\u00a0A.2 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in UHF \u2013 Band IV
Table\u00a0A.3 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in UHF \u2013 Band V (Low part) <\/td>\n<\/tr>\n\n 19<\/td>\n A.2 Narrow-band equipment
A.2.1 General
A.2.2 Operating frequency range: VHF
A.2.3 Operating frequency range: UHF
Table\u00a0A.4 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in UHF \u2013 Band V (High part)
Table\u00a0A.5 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in VHF \u2013 Band III, narrow-band equipment <\/td>\n<\/tr>\n\n 20<\/td>\n Table\u00a0A.6 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in UHF \u2013 Band IV, narrow-band equipment <\/td>\n<\/tr>\n \n 21<\/td>\n Table\u00a0A.7 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in UHF \u2013 Band V, narrow-band equipment <\/td>\n<\/tr>\n \n 22<\/td>\n Annex B (informative) Examples of measurement frequencies for channel spacing of 6 MHz
B.1 Wide-band equipment
B.1.1 General
B.1.2 Operating frequency range: VHF
B.1.3 Operating frequency range: UHF
Table\u00a0B.1 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in VHF \u2013 Band III
Table\u00a0B.2 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in UHF \u2013 Band IV
Table\u00a0B.3 \u2013 Allocation of measurement carrier frequencies (MHz)and intermodulation products in UHF \u2013 Band V (Low part) <\/td>\n<\/tr>\n\n 23<\/td>\n B.2 Narrow-band equipment
B.2.1 General
B.2.2 Operating frequency range: VHF
B.2.3 Operating frequency range: UHF
Table\u00a0B.4 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in UHF \u2013 Band V (High part)
Table\u00a0B.5 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in VHF \u2013 Band III, narrow-band equipment <\/td>\n<\/tr>\n\n 24<\/td>\n Table\u00a0B.6 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in UHF \u2013 Band IV, narrow-band equipment <\/td>\n<\/tr>\n \n 25<\/td>\n Table\u00a0B.7 \u2013 Allocation of measurement carrier frequencies (MHz) and intermodulation products in UHF \u2013 Band V, narrow-band equipment <\/td>\n<\/tr>\n \n 26<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2016<\/td>\n 28<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":229327,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[612,2641],"product_tag":[],"class_list":{"0":"post-229325","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-33-060-40","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/229325","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/229327"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=229325"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=229325"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=229325"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}