{"id":233685,"date":"2024-10-19T15:14:14","date_gmt":"2024-10-19T15:14:14","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61169-472015\/"},"modified":"2024-10-25T09:44:44","modified_gmt":"2024-10-25T09:44:44","slug":"bs-en-61169-472015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61169-472015\/","title":{"rendered":"BS EN 61169-47:2015"},"content":{"rendered":"

This part of IEC 61169<\/span> <\/span>, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with clamp coupling, typically for use in 75 \u03a9 cable networks (type F-Quick).<\/p>\n

It describes the interface dimensions with gauging information, electrical and mechanical performance including the mandatory tests selected from IEC 61169\u20111:2013<\/span> <\/span>, applicable to all DS relating to type F-Quick connectors.<\/p>\n

This specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules and inspection requirements.<\/p>\n

\n
\n NOTE\n <\/div>\n

This interface is typically used for indoor connections, which are easily disconnected and reconnected. The typical application is for F-type coaxial receiver leads or F-type coaxial patch cables. The interface may also be known as a Push-on connector. It is preferred to use the fixed (screwed) connectors type F according to IEC 61169\u201124:2009<\/span> <\/span>.<\/p>\n<\/div>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\nCONTENTS <\/td>\n<\/tr>\n
8<\/td>\nFOREWORD <\/td>\n<\/tr>\n
10<\/td>\n1 Scope
2 Normative references
3 Interface dimensions
3.1 Dimensions
3.1.1 Common dimensions <\/td>\n<\/tr>\n
11<\/td>\n3.1.2 Example of connector \u201cF-Quick\u201d type male plug with resilient outer conductor sleeve (indoor) physical dimensions
Figures
Figure\u00a01 \u2013 Connector \u201cF-Quick\u201d type male plug: general dimensions
Tables
Table\u00a01 \u2013 Connector \u201cF\u201d type male plug (indoor) <\/td>\n<\/tr>\n
12<\/td>\n3.1.3 Example of connector \u201cF-Quick\u201d type male plug with slotted outer conductor (indoor) physical dimensions
3.1.4 Example of connector \u201cF-Quick\u201d type male plug with slotted outer conductor and snap ring (indoor) physical dimensions
Figure\u00a02 \u2013 Example of connector \u201cF-Quick\u201d type male plug with resilient outer conductor sleeve (indoor)
Figure\u00a03 \u2013 Example of connector \u201cF-Quick\u201d type male plug with slotted outer conductor (indoor) <\/td>\n<\/tr>\n
13<\/td>\n3.2 Mechanical gauges
Figure\u00a04 \u2013 Example of connector \u201cF-Quick\u201d type male plug with slotted outer conductor and snap ring (indoor)
Figure\u00a05 \u2013 Mechanical gauge for resilient outer conductor <\/td>\n<\/tr>\n
14<\/td>\n4 Quality assessment procedures
4.1 General
4.2 Ratings and characteristics
Table\u00a02 \u2013 Ratings and characteristics <\/td>\n<\/tr>\n
16<\/td>\n4.3 Environmental characteristics for outdoor sockets
4.4 Test schedule and inspection requirements
4.4.1 Acceptance tests
4.4.2 Periodic tests
Table\u00a03 \u2013 Acceptance tests <\/td>\n<\/tr>\n
17<\/td>\nTable\u00a04 \u2013 Periodic tests <\/td>\n<\/tr>\n
18<\/td>\n4.5 Procedures for the quality conformance
4.5.1 Quality conformance inspection
4.5.2 Quality conformanceand its maintenance \u2013 General procedure
5 Instructions for preparation of detail specifications
5.1 General
5.2 Identification of the component <\/td>\n<\/tr>\n
19<\/td>\n5.3 Performance
5.4 Marking, ordering information and related matters
5.5 Selection of tests, test conditions and severities <\/td>\n<\/tr>\n
20<\/td>\n5.6 Blank detail specification pro-forma for type F-QUICK connector <\/td>\n<\/tr>\n
24<\/td>\n6 Marking
6.1 Marking of component
6.2 Marking and contents of package <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Radio-frequency connectors – Sectional specification for radio-frequency coaxial connectors with clamp coupling, typically for use in 75 \u03a9 cable networks (type F-Quick)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2015<\/td>\n28<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":233687,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[632,2641],"product_tag":[],"class_list":{"0":"post-233685","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-33-120-30","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/233685","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/233687"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=233685"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=233685"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=233685"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}