{"id":242073,"date":"2024-10-19T15:51:47","date_gmt":"2024-10-19T15:51:47","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-clc-ts-505762014\/"},"modified":"2024-10-25T10:43:09","modified_gmt":"2024-10-25T10:43:09","slug":"bsi-pd-clc-ts-505762014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-clc-ts-505762014\/","title":{"rendered":"BSI PD CLC\/TS 50576:2014"},"content":{"rendered":"
This Technical Specification gives the procedure and rules for extended application of results of tests carried out according to the test methods described in EN 50399<\/span> <\/span> and\/or EN 60332\u20111\u20112<\/span> <\/span>.<\/p>\n The EXAP rules described apply to EN 50399<\/span> <\/span> test results used for classification in classes B2 ca<\/sub>,C ca<\/sub> and D ca<\/sub>, additional smoke production classes s1, s2 and s3 and flaming droplets\/particles.<\/p>\n Cables of diameter 5,0 mm and less should be tested as bundles according to EN 50399<\/span> <\/span> and are excluded from these rules. Bundled cables are not included in the EXAP rules.<\/p>\n No rules have been developed for non circular cables which are not at present included in EN 50399<\/span> <\/span>.<\/p>\n A specific EXAP rule has been developed for the most common generic power cable families. A general EXAP rule has been developed for any power cable families. The general EXAP rule is not applicable to communication or optical fibre cables.<\/p>\n Multicore power cables with more than 5 cores are sometimes referred to as control cables with a rated voltage but for the purposes of this standard are considered as power cables.<\/p>\n<\/div>\n The general EXAP rule may be applied in the case of hybrid cables provided that the conditions of 6.1<\/span> are fulfilled.<\/p>\n<\/div>\n No EXAP rules have been developed for communication or optical fibre cables at the time of publication of this TS.<\/p>\n The use of the specific EXAP rule gives benefit in the lower number of cables to be tested for a range of cable constructions (product family).<\/p>\n An EXAP is only possible when cables belong to a defined family as defined in this Technical Specification.<\/p>\n No EXAP procedure and rules have been developed in respect of the results of tests carried out according to the test method described in EN 50267\u20112\u20113<\/span> <\/span>. As the parameters (pH and conductivity) for each cable in a family are determined based upon calculation using material test results, this is considered as a matter of direct application. Material test results taken from any one sample of finished cable from a family are sufficient to calculate the parameters for each cable in the family.<\/p>\n<\/div>\n Electric cables. Extended application of test results<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 5<\/td>\n Foreword <\/td>\n<\/tr>\n \n 7<\/td>\n 1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n\n 8<\/td>\n 3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8 <\/td>\n<\/tr>\n\n 9<\/td>\n 3.9
3.10
4 Extended application of test results (EXAP)
4.1 Product families for EXAP
4.2 EXAP procedure <\/td>\n<\/tr>\n\n 10<\/td>\n 4.3 Specific and general EXAP
5 Specific EXAP with safety margin
5.1 Rules for specific EXAP <\/td>\n<\/tr>\n\n 12<\/td>\n 5.2 Extension to cables larger than the tested range <\/td>\n<\/tr>\n \n 13<\/td>\n 6 General EXAP
6.1 Rules for general EXAP <\/td>\n<\/tr>\n\n 14<\/td>\n 6.2 Example of use of general EXAP (FIGRA) where m = 1 <\/td>\n<\/tr>\n \n 15<\/td>\n 6.3 Example of use of general EXAP (TSP) where m = 1 <\/td>\n<\/tr>\n \n 16<\/td>\n 6.4 Example of use of general EXAP (TSP) where m is less than 1 <\/td>\n<\/tr>\n \n 17<\/td>\n 7 EXAP for flaming droplets\/particles
8 EXAP for EN 60332-1-2 <\/td>\n<\/tr>\n\n 18<\/td>\n Annex A (informative) Checklist for specific EXAP <\/td>\n<\/tr>\n \n 20<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2014<\/td>\n 22<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":242077,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[493,2641],"product_tag":[],"class_list":{"0":"post-242073","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-060-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/242073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/242077"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=242073"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=242073"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=242073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}