{"id":247339,"date":"2024-10-19T16:16:42","date_gmt":"2024-10-19T16:16:42","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61300-2-242010\/"},"modified":"2024-10-25T11:23:19","modified_gmt":"2024-10-25T11:23:19","slug":"bs-en-61300-2-242010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61300-2-242010\/","title":{"rendered":"BS EN 61300-2-24:2010"},"content":{"rendered":"
IEC 61300-2-24:2010 identifies weaknesses in a ceramic alignment split sleeve which could lead to early failure of the component. This second edition constitutes a technical revision. Specific technical changes involve the addition of a dimension example of the reference gauge and the plate for the ceramic sleeve and a commonly used ceramic alignment sleeve for the 1,25 mm ceramic sleeve.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
5<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | 1 Scope 2 General description 3 Apparatus <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Figures Figure 1 \u2013 Apparatus used for screen testing of a ceramic alignment sleeve Tables Table 1 \u2013 Dimension example of the reference gauge and the plate for the ceramic sleeve <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 4 Procedure 5 Details to be specified Table 2 \u2013 Dimension example of a commonly used ceramic alignment sleeve <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Annex A (informative) Static fatigue for zirconia alignment sleeve <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Figure A.1 \u2013 Model of time-varying proof stress for a zirconia sleeve <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Figure A.2 \u2013 Calculated contour lines of gauge retention force and working stress along with inner and outer diameter of a zirconia sleeve Table A.1 \u2013 Measured static fatigue parameters for zirconia sleeves <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Figure A.3 \u2013 Calculated general relationship between \u03c3p\/\u03c3a and te, satisfying 0,1 FIT for 20 years use Figure A.4 \u2013 Calculated failure probability of screened zirconia sleeves along with working time <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Figure A.5 \u2013 Measured and calculated strength distribution of 2,5 mm zirconia sleeves (comparison between sleeves, extended proof tested or not) <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Figure A.6 \u2013 Measured strength distribution of 1,25 mm zirconia sleeves (comparison between sleeves, extended proof tested or not) <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Fibre optic interconnecting devices and passive components. Basic test and measurement procedures – Tests. Screen testing of ceramic alignment split sleeve by stress application<\/b><\/p>\n |