{"id":361555,"date":"2024-10-20T01:36:32","date_gmt":"2024-10-20T01:36:32","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iso-ts-213542020\/"},"modified":"2024-10-26T02:29:31","modified_gmt":"2024-10-26T02:29:31","slug":"bsi-pd-iso-ts-213542020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iso-ts-213542020\/","title":{"rendered":"BSI PD ISO\/TS 21354:2020"},"content":{"rendered":"

This document establishes a common basis for, and assistance in, the classification of applications and multiphase meters, as well as guidance and recommendations for the implementation and use of such meters.<\/p>\n

The so-called in-line multiphase flow meters (MPFMs) that directly measure the oil, water and gas flow rates, as well as the partial- and full-separation MPFMs are the main focus of this document. Conventional two- or three-phase separators are not included in this document. Only limited reference is made to wet-gas meters, since although wet-gas flow is a subset of multiphase flow, wet-gas measurement is covered by ISO\/TR 11583<\/span><\/span> and ISO\/TR 12748<\/span><\/span>.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
8<\/td>\nForeword <\/td>\n<\/tr>\n
9<\/td>\nIntroduction <\/td>\n<\/tr>\n
11<\/td>\n1 Scope
2 Normative references
3 Terms and definitions
3.1 Terms related to multiphase flow metering <\/td>\n<\/tr>\n
17<\/td>\n3.2 Terms related to metrology <\/td>\n<\/tr>\n
20<\/td>\n4 Symbols and subscripts
4.1 Symbols
4.2 Colours and symbols used in schematic drawings <\/td>\n<\/tr>\n
21<\/td>\n5 Multiphase flow
5.1 General <\/td>\n<\/tr>\n
22<\/td>\n5.2 Multiphase flow regime maps
5.2.1 General
5.2.2 Vertical flows <\/td>\n<\/tr>\n
23<\/td>\n5.2.3 Horizontal flows <\/td>\n<\/tr>\n
24<\/td>\n5.3 Slip effects <\/td>\n<\/tr>\n
25<\/td>\n5.4 Classification of multiphase flows <\/td>\n<\/tr>\n
26<\/td>\n6 Aims of multiphase flow measurement
6.1 General <\/td>\n<\/tr>\n
28<\/td>\n6.2 Individual-well surveillance or monitoring
6.2.1 General <\/td>\n<\/tr>\n
29<\/td>\n6.2.2 Production optimization
6.2.3 Flow assurance
6.3 Well testing
6.3.1 General <\/td>\n<\/tr>\n
30<\/td>\n6.3.2 Conventional well testing <\/td>\n<\/tr>\n
31<\/td>\n6.3.3 Well testing by MPFMs <\/td>\n<\/tr>\n
33<\/td>\n6.4 Production allocation metering <\/td>\n<\/tr>\n
36<\/td>\n6.5 Fiscal or custody transfer measurement
6.6 Summary of advantages and disadvantages of MPFMs
7 Production envelope and installation design guidelines
7.1 General <\/td>\n<\/tr>\n
37<\/td>\n7.2 Production envelope
7.2.1 Plotting the production envelope in the two-phase flow map <\/td>\n<\/tr>\n
38<\/td>\n7.2.2 Plotting the production envelope in the composition map <\/td>\n<\/tr>\n
39<\/td>\n7.3 MPFM measuring envelope
7.3.1 Plotting the MPFM measuring envelope in the two-phase flow map <\/td>\n<\/tr>\n
40<\/td>\n7.3.2 Plotting the MPFM measuring envelope in the composition map <\/td>\n<\/tr>\n
41<\/td>\n7.4 Using the flow maps during testing <\/td>\n<\/tr>\n
43<\/td>\n7.5 Cumulative performance plot <\/td>\n<\/tr>\n
44<\/td>\n7.6 Other considerations <\/td>\n<\/tr>\n
47<\/td>\n8 Performance specification
8.1 General <\/td>\n<\/tr>\n
48<\/td>\n8.2 Technical description
8.3 Specification of individual sensors and primary devices
8.4 Specification of output data and formats <\/td>\n<\/tr>\n
49<\/td>\n8.5 Measuring range, rated operating conditions and limiting conditions
8.6 Measurement uncertainty
8.6.1 General <\/td>\n<\/tr>\n
50<\/td>\n8.6.2 Measurement uncertainty evaluation of MPFMs
8.6.3 Influence quantities and sensitivity coefficients <\/td>\n<\/tr>\n
51<\/td>\n8.6.4 Repeatability
8.6.5 Stability and frequency response
8.7 Guideline on MPFM performance specification
8.7.1 General <\/td>\n<\/tr>\n
52<\/td>\n8.7.2 Technical descriptions
8.7.3 Specification of input data
8.7.4 Specification of output data <\/td>\n<\/tr>\n
53<\/td>\n8.7.5 Rated operating conditions and limiting conditions <\/td>\n<\/tr>\n
54<\/td>\n8.7.6 Measurement uncertainty <\/td>\n<\/tr>\n
56<\/td>\n8.7.7 Two-phase flow map
8.7.8 Composition map
9 Testing, calibration and adjustment
9.1 General <\/td>\n<\/tr>\n
57<\/td>\n9.2 Factory acceptance testing (FAT) <\/td>\n<\/tr>\n
58<\/td>\n9.3 Calibration and test of MPFMs
9.3.1 General
9.3.2 Performance verification in static conditions <\/td>\n<\/tr>\n
59<\/td>\n9.3.3 Performance verification in dynamic conditions <\/td>\n<\/tr>\n
61<\/td>\n9.3.4 Factory test
9.3.5 Test facility <\/td>\n<\/tr>\n
63<\/td>\n9.3.6 In situ test <\/td>\n<\/tr>\n
65<\/td>\n9.3.7 Further information on performance testing <\/td>\n<\/tr>\n
68<\/td>\n9.3.8 Test report <\/td>\n<\/tr>\n
70<\/td>\n9.4 Adjustment of MPFMs
9.4.1 General
9.4.2 Adjustment based on static configuration
9.4.3 Adjustment based on performance verification in dynamic conditions <\/td>\n<\/tr>\n
71<\/td>\n9.5 Blind tests
9.5.1 Scope and objective of MPFM blind test
9.5.2 Organization and implementation
9.5.3 Multiphase flow loop <\/td>\n<\/tr>\n
72<\/td>\n9.5.4 Test matrix <\/td>\n<\/tr>\n
73<\/td>\n9.5.5 Information to be provided by MPFM vendors
9.5.6 Information provided to MPFM vendors
9.5.7 Test completion <\/td>\n<\/tr>\n
74<\/td>\n9.5.8 Test results and deliverables
10 Field installation and commissioning
10.1 General
10.2 Installation considerations <\/td>\n<\/tr>\n
75<\/td>\n10.3 Installation and site integration
10.3.1 General <\/td>\n<\/tr>\n
76<\/td>\n10.3.2 Installation requirements
10.3.3 Electrical connections and power requirements
10.3.4 Function test
10.3.5 Fluid calculation checks
10.4 Commissioning
10.4.1 General <\/td>\n<\/tr>\n
77<\/td>\n10.4.2 Preparation
10.4.3 Documentation and equipment
10.4.4 On site authorization
10.4.5 Commissioning activities <\/td>\n<\/tr>\n
78<\/td>\n10.5 Start-up
11 \u200bVerification during operation
11.1 General <\/td>\n<\/tr>\n
79<\/td>\n11.2 Baseline monitoring <\/td>\n<\/tr>\n
80<\/td>\n11.3 Self-checking, self-diagnostic capabilities and internal redundancy
11.4 Comparison with model-based multiphase flow calculations
11.5 Two meters in series <\/td>\n<\/tr>\n
81<\/td>\n11.6 Mobile test units
11.7 Tracer technology <\/td>\n<\/tr>\n
82<\/td>\n11.8 Injection
11.9 Sampling
11.9.1 General
11.9.2 Sampling for information about WLR
11.10 Imbalances and reconciliation factor <\/td>\n<\/tr>\n
84<\/td>\n11.11 Geo-chemical fingerprinting
11.12 Subsea systems verification <\/td>\n<\/tr>\n
85<\/td>\nAnnex A (informative) Multiphase meter technologies <\/td>\n<\/tr>\n
97<\/td>\nAnnex B (informative) Fluid properties and hydrocarbon behaviour <\/td>\n<\/tr>\n
102<\/td>\nAnnex C (informative) Example of field test reference measurements <\/td>\n<\/tr>\n
106<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Measurement of multiphase fluid flow<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2020<\/td>\n110<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":361563,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1081,2641],"product_tag":[],"class_list":{"0":"post-361555","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-75-180-30","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/361555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/361563"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=361555"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=361555"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=361555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}