{"id":36643,"date":"2024-10-17T04:59:01","date_gmt":"2024-10-17T04:59:01","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e350-2005\/"},"modified":"2024-10-24T15:02:26","modified_gmt":"2024-10-24T15:02:26","slug":"astm-e350-2005","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e350-2005\/","title":{"rendered":"ASTM-E350 2005"},"content":{"rendered":"<\/p>\n

1.1 These test methods cover the chemical analysis of carbon steels, low-alloy steels, silicon electrical steels, ingot iron, and wrought iron having chemical compositions within the following limits:<\/p>\n

1.3 Test methods for the determination of several elements not included in this standard can be found in Test Methods E 30 and Test Methods E 1019.<\/p>\n

1.4 Some of the concentration ranges given in are too broad to be covered by a single test method and therefore this standard contains multiple test methods for some elements. The user must select the proper test method by matching the information given in the Scope and Interference sections of each test method with the composition of the alloy to be analyzed.<\/p>\n

1.5 The values stated in SI units are to be regarded as standard. In some cases, exceptions allowed in IEEE\/ASTM SI 10 are also used.<\/p>\n

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section and in special ‘Warning’ paragraphs throughout these test methods.<\/p>\n

1.6 This test method covers the determination of manganese in concentrations from 0.01 to 2.5 %.<\/p>\n

1.7 This test method covers the determination of phosphorus in concentrations from 0.003 to 0.09 %.<\/p>\n

1.8 The upper limit of the scope has been set at 0.09 % because sufficient numbers of test materials containing higher phosphorus contents were unavailable for testing in accordance with Practice E 173. However, recognizing that the chemical principles used in this test method are capable of handling higher concentrations, the test method includes a calibration procedure up to 0.25 %. Users of this test method are cautioned that its use above 0.09 % is not supported by interlaboratory testing.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope <\/td>\n<\/tr>\n
2<\/td>\nReferenced Documents
Significance and Use
Apparatus, Reagents, and Instrumental Practices <\/td>\n<\/tr>\n
3<\/td>\nHazards
Sampling
Interlaboratory Studies and Rounding Calculated Values
Scope
Summary of Test Method
Concentration Range
Stability of Color
Interferences
Reagents
Preparation of Calibration Curve <\/td>\n<\/tr>\n
4<\/td>\nProcedure
Calculation
Precision and Bias
Scope
TABLE 1 <\/td>\n<\/tr>\n
5<\/td>\nSummary of Test Method
Concentration Range
Stability of Color
Interferences
Apparatus
Reagents
Preparation of Calibration Curve for Concentrations from 0.005 to 0.05 mg\/100 mL
Preparation of Calibration Curve for Concentrations from 0.05 to 0.30 mg\/100 mL <\/td>\n<\/tr>\n
6<\/td>\nProcedure
Calculation
Precision and Bias
TABLE 2 <\/td>\n<\/tr>\n
8<\/td>\nTABLE 3 <\/td>\n<\/tr>\n
10<\/td>\nTABLE 4 <\/td>\n<\/tr>\n
11<\/td>\nTABLE 5 <\/td>\n<\/tr>\n
14<\/td>\nTABLE 6 <\/td>\n<\/tr>\n
15<\/td>\nTABLE 7 <\/td>\n<\/tr>\n
17<\/td>\nTABLE 8 <\/td>\n<\/tr>\n
18<\/td>\nTABLE 9 <\/td>\n<\/tr>\n
19<\/td>\nFIG. 1 <\/td>\n<\/tr>\n
20<\/td>\nTABLE 10 <\/td>\n<\/tr>\n
23<\/td>\nTABLE 11 <\/td>\n<\/tr>\n
24<\/td>\nTABLE 12 <\/td>\n<\/tr>\n
26<\/td>\nTABLE 13 <\/td>\n<\/tr>\n
29<\/td>\nTABLE 14 <\/td>\n<\/tr>\n
30<\/td>\nTABLE 15 <\/td>\n<\/tr>\n
31<\/td>\nTABLE 16 <\/td>\n<\/tr>\n
34<\/td>\nTABLE 17 <\/td>\n<\/tr>\n
35<\/td>\nTABLE 18 <\/td>\n<\/tr>\n
36<\/td>\nFIG. 2 <\/td>\n<\/tr>\n
38<\/td>\nTABLE 19 <\/td>\n<\/tr>\n
40<\/td>\nTABLE 20 <\/td>\n<\/tr>\n
43<\/td>\nTABLE 21 <\/td>\n<\/tr>\n
44<\/td>\nTABLE 22 <\/td>\n<\/tr>\n
46<\/td>\nTABLE 23 <\/td>\n<\/tr>\n
47<\/td>\nTABLE 24 <\/td>\n<\/tr>\n
48<\/td>\nTABLE 25 <\/td>\n<\/tr>\n
50<\/td>\nTABLE 26 <\/td>\n<\/tr>\n
51<\/td>\nTABLE 27 <\/td>\n<\/tr>\n
53<\/td>\nTABLE 28 <\/td>\n<\/tr>\n
54<\/td>\nTABLE 29 <\/td>\n<\/tr>\n
57<\/td>\nTABLE 30 <\/td>\n<\/tr>\n
59<\/td>\nTABLE 31 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

E350-95(2005)e1 Standard Test Methods for Chemical Analysis of Carbon Steel, Low-Alloy Steel, Silicon Electrical Steel, Ingot Iron, and Wrought Iron<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2005<\/td>\n59<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":36644,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1090,2637],"product_tag":[],"class_list":{"0":"post-36643","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-77-040-30","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/36643","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/36644"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=36643"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=36643"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=36643"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}