{"id":388050,"date":"2024-10-20T03:43:15","date_gmt":"2024-10-20T03:43:15","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e119-40\/"},"modified":"2024-10-26T06:49:01","modified_gmt":"2024-10-26T06:49:01","slug":"astm-e119-40","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e119-40\/","title":{"rendered":"ASTM-E119"},"content":{"rendered":"<\/p>\n
1.1 The test methods described in this fire-test-response standard are applicable to assemblies of masonry units and to composite assemblies of structural materials for buildings, including bearing and other walls and partitions, columns, girders, beams, slabs, and composite slab and beam assemblies for floors and roofs. They are also applicable to other assemblies and structural units that constitute permanent integral parts of a finished building.<\/p>\n
1.2 It is the intent that classifications shall register comparative performance to specific fire-test conditions during the period of exposure and shall not be construed as having determined suitability for use under other conditions or after fire exposure.<\/p>\n
1.3 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions.<\/span> .<\/span><\/p>\n 1.4 These test methods prescribe a standard fire exposure for comparing the test results of building construction assemblies. The results of these tests are one factor in assessing predicted fire performance of building construction and assemblies. Application of these test results to predict the performance of actual building construction requires the evaluation of test conditions.<\/p>\n 1.5 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.<\/p>\n 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/span><\/p>\n 1.7 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.<\/p>\n E119-08a Standard Test Methods for Fire Tests of Building Construction and Materials<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope <\/td>\n<\/tr>\n \n 2<\/td>\n Referenced Documents
Terminology
Significance and Use
Time-Temperature Curve
FIG. 1 <\/td>\n<\/tr>\n\n 3<\/td>\n Furnace Temperatures
Temperatures of Unexposed Surfaces of Floors, Roofs, Walls, and Partitions <\/td>\n<\/tr>\n\n 4<\/td>\n Report of Results
Test Specimen
Fire Endurance Test
Hose Stream Test <\/td>\n<\/tr>\n\n 5<\/td>\n Protection and Conditioning of Test Specimen
Precision and Bias
Size of Specimen
Loading
TABLE 1 <\/td>\n<\/tr>\n\n 6<\/td>\n Conditions of Acceptance
Size of Specimen
Conditions of Acceptance
Size of Specimen
Loading
Condition of Acceptance
Application
Size and Characteristics of Specimen
Temperature Measurement <\/td>\n<\/tr>\n\n 7<\/td>\n Exposure to Fire
Conditions of Acceptance
Application
Size and Characteristics of Specimen
Loading
Temperature Measurement
FIG. 2 <\/td>\n<\/tr>\n\n 8<\/td>\n Conditions of Acceptance\u2014Restrained Assembly
Conditions of Acceptance\u2014Unrestrained Assembly
Report of Results
Application
FIG. 3 <\/td>\n<\/tr>\n\n 9<\/td>\n Size and Characteristics of Specimen
Loading
Conditions of Acceptance
Application
Temperature Measurement
Conditions of Acceptance
Application
Size and Characteristics of Specimen <\/td>\n<\/tr>\n\n 10<\/td>\n Temperature Measurement
Conditions of Acceptance
Application
Size of Specimen
Temperature Performance of Protective Membranes
Conditions of Performance
Report of Results
Keywords <\/td>\n<\/tr>\n\n 11<\/td>\n A1. REQUIREMENTS FOR THERMOCOUPLE PADS
A1.1 <\/td>\n<\/tr>\n\n 12<\/td>\n X1. STANDARD TIME-TEMPERATURE CURVE FOR CONTROL OF FIRE TESTS
TABLE X1.1 <\/td>\n<\/tr>\n\n 13<\/td>\n X2. SUGGESTED REPORT FORM
X2.1
X2.2
X2.3
X2.4 <\/td>\n<\/tr>\n\n 14<\/td>\n X2.5
X2.6
X2.7
X2.8
X2.9
X2.10
X3. GUIDE FOR DETERMINING CONDITIONS OF RESTRAINT FOR FLOOR AND ROOF ASSEMBLIES AND FOR INDIVIDUAL BEAMS
X3.1
X3.2
X3.3
X3.4
X3.5 <\/td>\n<\/tr>\n\n 15<\/td>\n X3.6
X4. METHOD OF CORRECTING FIRE ENDURANCE FOR CONCRETE SLABS DETERMINED BY UNEXPOSED SURFACE TEMPERATURE RISE FOR NONSTANDARD MOISTURE CONTENT
X4.1 Scope
X4.2 Symbols
TABLE X3.1 <\/td>\n<\/tr>\n\n 16<\/td>\n X4.3 Calculation of Moisture Content
X4.4 Correction Procedure
X4.5 Illustrative Example
TABLE X4.1
TABLE X4.2
TABLE X4.3 <\/td>\n<\/tr>\n\n 17<\/td>\n FIG. X4.1 <\/td>\n<\/tr>\n \n 18<\/td>\n X5. COMMENTARY
X5.1 Introduction
X5.2 Historical Aspects
X5.3 Fire-Load Concept
X5.4 Scope and Significance <\/td>\n<\/tr>\n\n 19<\/td>\n X5.5 Test Furnaces
X5.6 Temperature-Time Curve
X5.7 Test Specimen
X5.8 Loading <\/td>\n<\/tr>\n\n 20<\/td>\n X5.9 Integrity
X5.10 Conditions of Tests
X5.11 Other Observations
X5.12 Protective Membranes
X5.13 Future
X6. ASBESTOS PADS
X6.1 History of Asbestos Pads
X6.2 Previous Requirements for Asbestos Pad <\/td>\n<\/tr>\n\n 21<\/td>\n X7. LOADING FOR TEST SPECIMENS
X7.1 General
X7.2 Superimposed Load Calculation <\/td>\n<\/tr>\n\n 22<\/td>\n X7.3 Concrete and Structural Steel Floor and Roof Specimens <\/td>\n<\/tr>\n \n 23<\/td>\n X7.4 Concrete Columns
FIG. X7.1
FIG. X7.2 <\/td>\n<\/tr>\n\n 24<\/td>\n X7.5 Wood Specimens
FIG. X7.3 <\/td>\n<\/tr>\n\n 28<\/td>\n X7.6 Cold Formed Steel Specimens
FIG. X7.4 <\/td>\n<\/tr>\n\n 29<\/td>\n FIG. X7.5 <\/td>\n<\/tr>\n \n 30<\/td>\n REFERENCES <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2008<\/td>\n 31<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":388058,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[240,1253,2637],"product_tag":[],"class_list":{"0":"post-388050","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-220-50","7":"product_cat-91-100-01","8":"product_cat-astm","10":"first","11":"instock","12":"sold-individually","13":"shipping-taxable","14":"purchasable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/388050","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/388058"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=388050"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=388050"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=388050"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}