{"id":430377,"date":"2024-10-20T07:22:49","date_gmt":"2024-10-20T07:22:49","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/vt-cbes-2020\/"},"modified":"2024-10-26T14:02:05","modified_gmt":"2024-10-26T14:02:05","slug":"vt-cbes-2020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/vt\/vt-cbes-2020\/","title":{"rendered":"VT CBES 2020"},"content":{"rendered":"
None<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
7<\/td>\n | PREFACE Introduction Development Background Update Process <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | EFFECTIVE USE OF THE 2020 VERMONT COMMERCIAL BUILDING ENERGY STANDARDS Arrangement and Format of the 2020 CBES Italicized Terms <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Marginal Markings Abbreviations and Notations <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | – add – C302.2 Climatic data0F . <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | TABLE C303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | TABLE 4.2.1.1 Building Performance Factor (BPF) <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | SECTION C402 BUILDING ENVELOPE REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | TABLE C402.1(1) <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | TABLE C402.1(2) BUILDING ENVELOPE REQUIREMENTS\u2014METAL BUILDING ASSEMBLY DESCRIPTIONS <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | TABLE C402.1(3) ASSEMBLY U-FACTORS FOR METAL BUILDING ROOFS <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | – add – TABLE C402.1(4) ASSEMBLY U-FACTORS FOR ATTIC ROOFS WITH WOOD JOISTS TABLE C402.1(4) ASSEMBLY U-FACTORS FOR ATTIC ROOFS WITH WOOD JOISTS <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | TABLE C402.1(5) ASSEMBLY U-FACTORS FOR METAL BUILDING WALLS <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | TABLE C402.1(6) ASSEMBLY U-FACTORS FOR METAL-FRAMED WALLS <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | – add – TABLE C402.1(7) ASSEMBLY U-FACTORS FOR WOOD-FRAMED WALLS TABLE C402.1(7) ASSEMBLY U-FACTORS FOR WOOD-FRAMED WALLS <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | TABLE C402.3 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS – delete – TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | – add – C402.4.1.2 Continuous Air Barrier Commissioning – add – C402.4.1.2.1 Building Envelope Commissioning Guideline <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | TABLE C402.4.1.2.1 BUILDING ENVELOPE COMMISIONING CHECKLIST <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | SECTION C403 BUILDING MECHANICAL SYSTEMS <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | – delete and replace – TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | TABLE C403.3.2(1)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | – delete and replace – TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | TABLE C403.3.2(2)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | – delete and replace – TABLE C403.3.2(7) WATER CHILLING PACKAGES \u2013 EFFICIENCY REQUIREMENTS TABLE C403.3.2(7) WATER CHILLING PACKAGES \u2013 EFFICIENCY REQUIREMENTSa, b, d <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | TABLE C403.3.2(10) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR CONDITIONERS <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | – add – TABLE C403.3.2(11) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS TABLE C403.3.2(11) MINIMUM EFFICIENCY ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | – modify – TABLE C403.3.2(10) HEAT TRANSFER EQUIPMENT to TABLE C403.3.2(12) HEAT TRANSFER EQUIPMENT <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | – delete – TABLE C403.4.4 VARIABLE SPEED DRIVE (VSD) REQUIREMENTS FOR DEMAND-CONTROLLED PUMPS <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | – delete and replace – TABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITSTABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS – delete and replace – TABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSbTABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | – delete and replace – TABLE C403.8.5.1 COOLING SYSTEMS TABLE C403.8.5.1 COOLING SYSTEMS <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | – delete and replace – TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches) TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches)a, c <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | TABLE C404.2\u2014continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | – delete and replace – C405.2.1.4 Occupant sensor control function for egress illumination. <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | – add – C405.2.3.1.1 Dimming. <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | FIGURE C405.2.3.3(4) DAYLIGHT ZONE ADJACENT TO CLERESTORY FENESTRATION IN A WALL <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | – delete and replace – TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | TABLE C405.3.2(2)\u2014continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | TABLE C405.3.2(2)\u2014continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | TABLE C405.3.2(2)\u2014continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | TABLE C405.4.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | – delete – TABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS – add – C405.10 Electric Vehicle Charging Stations <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | TABLE C405.11 ELECTRIC VEHICLE CHARGING PARKING SPACES <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | – modify \u2013 FIGURE C408.2.4 COMMISSIONING COMPLIANCE CHECKLIST to FIGURE C407.2.4 COMMISSIONING COMPLIANCE CHECKLIST <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | APPENDIX CA SOLAR-READY ZONE\u2014COMMERCIAL SECTION CA103 SOLAR-READY ZONE <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Vermont Commercial Building Energy Standards (CBES) effective September 1, 2020<\/b><\/p>\n |