{"id":434776,"date":"2024-10-20T07:45:58","date_gmt":"2024-10-20T07:45:58","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-62769-82023\/"},"modified":"2024-10-26T14:44:02","modified_gmt":"2024-10-26T14:44:02","slug":"bs-en-iec-62769-82023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-62769-82023\/","title":{"rendered":"BS EN IEC 62769-8:2023"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3 Terms, definitions, abbreviated terms, acronyms and conventions 3.1 Terms and definitions 3.2 Abbreviated terms and acronyms 3.3 Conventions 3.3.1 Capitalization 3.3.2 Graphical notation Figures Figure 1 \u2013 OPC UA Graphical notation for NodeClasses <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Figure 2 \u2013 OPC UA Graphical notation for References Figure 3 \u2013 OPC UA Graphical notation example <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4 Overview Figure 4 \u2013 Optimized Type Reference Figure 5 \u2013 Similarity of OPC-UA objects and EDD collections <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5 Basic principles of explicit mapping 5.1 Semantic maps to tag EDD constructs <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.2 Alias collections 5.2.1 General 5.2.2 Syntax of semantic id for alias mappings 5.3 Namespace Alias Collection Figure 6 \u2013 Syntax of sematic ids for EDD entry points Figure 7 \u2013 Syntax of sematic id for alias mapping <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.4 Reference Type Alias Collection Figure 8 \u2013 Namespace Collection <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Figure 9 \u2013 Reference Type Collection <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.5 Semantic maps for OPC-UA type mapping 5.5.1 General 5.5.2 Syntax of semantic Id for OPC-UA Figure 10 \u2013 Use of SEMANTIC_MAP for OPC-UA types Figure 11 \u2013 Syntax of OPC-UA type identifier Figure 12 \u2013 Semantic map example <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.6 Semantic maps for unit mapping 5.6.1 General 5.6.2 Syntax of semantic Id for Units 5.7 Explicit mapping of OPC-UA variable types Figure 13 \u2013 Syntax of Unit Identifier Figure 14 \u2013 Most simple mapping example <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Figure 15 \u2013 EDD variable mapped to an OPC-UA BaseDataVariableType <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 5.8 Explicit mapping of complex OPC-UA types Figure 16 \u2013 Simple mapping example with range and unit <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Figure 17 \u2013 Mapping of a collection to an OPC-UA variable <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 5.9 Explicit mapping of nested object and variable types 5.9.1 General 5.9.2 When to use collections 5.9.3 When to use menus 5.9.4 OPC-UA diagram of nested mapping example <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 5.9.5 EDD snippet of nested mapping example Figure 18 \u2013 Nested objects and variables <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Figure 19 \u2013 Example of nested objects and variables <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 5.10 Explicit mapping of methods 5.10.1 Mapping EDD methods to OPC-UA objects, variables or properties 5.10.2 Mapping EDD methods to OPC-UA methods Figure 20 \u2013 Simple method <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 5.11 Explicit mapping of alarms Figure 21 \u2013 Example of simple method mapping <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Table 1 \u2013 Alarm properties mapping <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Figure 22 \u2013 Supported Alarms <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 5.12 Explicit mapping of units Figure 23 \u2013 Example of alarm mapping <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 5.13 Explicit mapping of aggregated data by methods Figure 24 \u2013 EDD example of explicit unit mapping <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Figure 25 \u2013 Instance of PADIMType <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 5.14 Explicit mapping with reference types 5.14.1 General Figure 26 \u2013 Method of type DD_STRING mapped to a string variable <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 5.14.2 Example: Adding an additional property to an instance of variable Figure 27 \u2013 Adding a property which is not defined in mapped type <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 5.14.3 Example: Adding an additional variable to an instance of a variable or an object Figure 28 \u2013 EDD example of adding a property <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Figure 29 \u2013 Adding a component <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 5.14.4 Example: Adding an OPC-UA alias to a variable Figure 30 \u2013 EDD example adding a component <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Figure 31 \u2013 Adding an alias Figure 32 \u2013 EDD example adding an alias <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 6 Implicit rules 6.1 BrowseName of OPC-UA object 6.1.1 General 6.1.2 Overruling of BrowseName implicit rule 6.2 DisplayName of OPC-UA object 6.2.1 General 6.2.2 Overruling of DisplayName implicit rule 6.3 HANDLING and AccessLevel 6.4 VALIDITY and availability <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 6.5 Return values of EDD methods 6.5.1 EDD methods mapped to OPC-UA objects, variables, properties or attributes 6.5.2 EDD methods mapped to OPC-UA methods 6.6 Units 6.7 Range 6.8 Forward cast 6.9 Backward cast 6.10 Abstract OPC-UA types <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 6.11 Unmapped mandatory OPC-UA properties, components and folders 6.12 Semantic Identifiers and Dictionary References Figure 33 \u2013 Explicit mapping of dictionary entries <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 6.13 Implicit Type Casts for OPC-UA DataTypes Figure 34 \u2013 Combination with an implicitly mapped dictionary entry Table 2 \u2013 Implicit Type Casts <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 7 Mapping the EDD device model into PA-DIM (OPC 30081) 7.1 General 7.2 Explicit mapping of sub-devices 7.3 Adding sub-devices <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Figure 35 \u2013 Subdevices <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Figure 36 \u2013 Subdevices example <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Field device integration (FDI\u00ae) – EDD to OPC-UA Mapping<\/b><\/p>\n |