{"id":439316,"date":"2024-10-20T08:08:24","date_gmt":"2024-10-20T08:08:24","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-23-30465164-dc\/"},"modified":"2024-10-26T15:15:06","modified_gmt":"2024-10-26T15:15:06","slug":"bsi-23-30465164-dc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-23-30465164-dc\/","title":{"rendered":"BSI 23\/30465164 DC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 30465164-NC.pdf <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | 21A_853e_CD.pdf <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4 Parameters measurement tolerances 5 Marking and designation 5.1 Marking <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 5.2 Cell designation <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.3 Battery designation 5.3.1 General <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.3.2 Battery structure formulation 5.4 Cell or battery termination 6 Electrical tests 6.1 General <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.2 Charging procedure for test purposes 6.3 Discharge performance 6.3.1 Discharge performance at +25 C <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.3.2 Discharge performance at low temperature 6.3.3 High rate permissible current 6.3.3.1 General 6.3.3.2 Test method <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.3.3.3 Acceptance criterion 6.4 Charge (capacity) retention and recovery 6.4.1 General 6.4.2 Test method 6.4.3 Acceptance criterion <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.5 Cell and battery internal resistance 6.5.1 General 6.5.2 Measurement of the internal a.c. resistance 6.5.2.1 Measurement 6.5.2.2 Acceptance criterion 6.5.3 Measurement of the internal d.c. resistance 6.5.3.1 Measurement <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.5.3.2 Acceptance criterion 6.6 Endurance 6.6.1 Endurance in cycles 6.6.1.1 General 6.6.1.2 Measurement <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 6.6.1.3 Acceptance criterion 6.6.2 Endurance in storage at constant voltage (permanent charge life) 6.6.2.1 General 6.6.2.2 Measurement <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 6.6.2.3 Acceptance criterion 7 Type test conditions 7.1 General 7.2 Sample size <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 7.3 Conditions for type approval 7.3.1 Dimensions <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 7.3.2 Electrical tests 7.3.2.1 The manufacturer shall declare the rated capacity (Cn Ah) of the cell, cell block or battery based on its performance under the conditions specified in 6.3.1 and Table 6. 7.3.2.2 In order to meet the requirements of this standard, all samples shall meet all the performances specified in Table 6. The minimum levels for meeting the requirements of the electrical tests are expressed as percentages of the rated capacity. 7.3.2.3 The test results can be replaced by the results performed under the more severe condition which are specified in Table 7. <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Annex A (informative) Battery structure information A.1 Example 1 A.2 Example 2 A.3 Example 3 A.4 Example 4 <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | A.5 Example 5 A.6 Example 6 <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | A.7 Example 7 A.8 Example 8 <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | A.9 Example 9 <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" BS EN IEC 62620. Secondary cells and batteries containing alkaline or other non-acid electrolytes. Secondary lithium cells and batteries for use in industrial applications<\/b><\/p>\n |