{"id":447528,"date":"2024-10-20T08:52:27","date_gmt":"2024-10-20T08:52:27","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-62561-42023-tc\/"},"modified":"2024-10-26T16:32:26","modified_gmt":"2024-10-26T16:32:26","slug":"bs-en-iec-62561-42023-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-62561-42023-tc\/","title":{"rendered":"BS EN IEC 62561-4:2023 – TC"},"content":{"rendered":"
IEC 62561-4:2023 is available as IEC 62561-4:2023 RLV<\/span> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-4:2023 deals with the requirements and tests for metallic and non-metallic conductor fasteners that are used to retain and support the air-termination, down-conductor and earth-termination systems. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) alignment with the latest edition of ISO IEC 60068-2-52:2017 relating to salt mist atmosphere treatment; b) alignment with the new edition of ISO 22479:2019 relating to humid sulphurous atmosphere treatment; c) new normative annex for the applicability of previous tests.<\/p>\n Tracked Changes. Lightning protection system components (LPSC) – Requirements for conductor fasteners<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 38<\/td>\n undefined <\/td>\n<\/tr>\n \n 41<\/td>\n Annex ZA (normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n \n 42<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 44<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 46<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 47<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 48<\/td>\n 3 Terms and definitions
4 Classification
4.1 According to the material of the conductor fastener
4.2 According to the fixing arrangement of the conductor within the conductor fastener
4.3 According to the conductor clamping arrangement
5 Requirements
5.1 General <\/td>\n<\/tr>\n\n 49<\/td>\n 5.2 Environmental requirements
5.2.1 Corrosion resistance
5.2.2 Ultraviolet (UV) light resistance
5.3 Mechanical strength
5.3.1 Perpendicular and axial loads
5.3.2 Impact tests
5.4 Installation instructions <\/td>\n<\/tr>\n\n 50<\/td>\n 5.5 Marking
5.5.1 Content of marking
5.5.2 Durability and legibility
6 Tests
6.1 General test conditions <\/td>\n<\/tr>\n\n 51<\/td>\n 6.2 Preparation of the specimen
6.3 Environmental influence test
6.3.1 General
6.3.2 Metallic <\/td>\n<\/tr>\n\n 52<\/td>\n 6.3.3 Non-metallic
6.3.4 Composite
Figure 1 \u2013 Basic arrangement of specimens <\/td>\n<\/tr>\n\n 53<\/td>\n 6.4 Resistance to mechanical effects
6.4.1 Lateral load test
Figure 2 \u2013 Basic arrangement of lateral load test <\/td>\n<\/tr>\n\n 54<\/td>\n 6.4.2 Axial load test
Figure 3 \u2013 Typical arrangement for axial movement test <\/td>\n<\/tr>\n\n 55<\/td>\n 6.4.3 Impact test
6.5 Installation instructions
6.5.1 General conditions
6.5.2 Acceptance criteria
6.6 Marking test
6.6.1 General test conditions
6.6.2 Acceptance criteria <\/td>\n<\/tr>\n\n 56<\/td>\n 6.7 Construction
7 Electromagnetic compatibility (EMC)
8 Structure and content of the test report
8.1 General
8.2 Report identification <\/td>\n<\/tr>\n\n 57<\/td>\n 8.3 Specimen description
8.4 Conductor
8.5 Standards and references
8.6 Test procedure
8.7 Testing equipment, description
8.8 Measuring instruments description
8.9 Results and parameters recorded <\/td>\n<\/tr>\n\n 58<\/td>\n 8.10 Statement of pass and fail <\/td>\n<\/tr>\n \n 59<\/td>\n Annex A (normative) Resistance to corrosion for metallic and composite conductor fasteners
A.1 General
A.2 Salt mist treatment
A.3 Humid sulphurous atmosphere treatment
A.4 Ammonia atmosphere treatment <\/td>\n<\/tr>\n\n 60<\/td>\n Annex B (normative) Environmental test for non-metallic and composite conductor fasteners \u2013 Resistance to ultraviolet light
B.1 General
B.2 Test
B.3 First alternative test to Clause B.2
B.4 Second alternative test to Clause B.2 <\/td>\n<\/tr>\n\n 61<\/td>\n Annex C (normative) Applicability of previous tests
Table C.1 \u2013 Differences in the requirements for conductor fasteners complying with IEC 62561\u20114:2010 or 62561\u20114:2017 <\/td>\n<\/tr>\n\n 62<\/td>\n Annex D (normative) Flow chart of tests for conductor fastener
Figure D.1 \u2013 Flowchart of tests for conductor fastener <\/td>\n<\/tr>\n\n 63<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2023<\/td>\n 65<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":447534,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-447528","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/447528","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/447534"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=447528"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=447528"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=447528"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}