{"id":447548,"date":"2024-10-20T08:52:34","date_gmt":"2024-10-20T08:52:34","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-23-30484005-dc-2023\/"},"modified":"2024-10-26T16:32:44","modified_gmt":"2024-10-26T16:32:44","slug":"bsi-23-30484005-dc-2023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-23-30484005-dc-2023\/","title":{"rendered":"BSI 23\/30484005 DC 2023"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
3<\/td>\n | 68_757_CD_CP <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Draft%20Second%20CD_Open_circuit_measurement_method_Superconducting_VSM%20_202311_Clean%20tempNoteJSi <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4 General principle 4.1 Principle of the method <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4.2 Superconducting magnet (SCM) 4.3 Magnetic field strength sensor (H sensor) 4.4 Magnetic dipole moment detection coil (M coil) <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.5 Specimen rod and moving device 4.6 Measuring devices and the data processing device <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5 Test specimen 6 Preparation of measurement 6.1 Measurement of volume of the test specimen 6.2 Initial magnetization of the test specimen to saturation <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 7 Determination of magnetic polarization 7.1 Measurement of the magnetic dipole moment 7.1.1 SCM-VSM method 7.1.2 SCM-Extraction method <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 7.2 Determination of magnetic polarization 8 Measurement of magnetic field 9 Calibration of the magnetic dipole moment detection coil (M coil) 10 Determination of demagnetization curve <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 11 Demagnetizing field correction 11.1 General 11.2 Method A: Method using a demagnetizing factor determined by the shape of the test specimen only <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 11.3 Method B: Method using a demagnetizing factor determined by the shape and the magnetic susceptibility of the test specimen 11.4 Method C: Method using an inverse analysis considering the spatial distribution of the self-demagnetizing field strength in the test specimen <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 12 Determination of principal magnetic properties 12.1 Remanent magnetic polarization Jr 12.2 Maximum energy product (BH)max 12.3 Coercivity (HcJ and HcB) 13 Reproducibility of the measurements 14 Test report <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex A (informative) Demagnetizing field correction <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Annex B (informative) Details of the demagnetizing field correction B.1 General B.2 Symbols <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | B.3 Method using a demagnetizing factor determined by the shape and magnetic susceptibility of the test specimen (Method B) <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | B.4 Method using an inverse analysis considering the spatial distribution of the self-demagnetizing field strength in the test specimen (Method C) <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Annex C (informative) VSM measurement of the test specimen at elevated temperatures <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex D (informative) Effect of test specimen dimensions on the magnetic properties <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex E (informative) Comparison of the magnetic properties measured with a superconducting VSM and a permeameter <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" BS EN IEC 60404-18 Magnetic materials – Part 18: Permanent magnet (magnetically hard) materials – Methods of measurement of the magnetic properties in an open magnetic circuit using a superconducting magnet<\/b><\/p>\n |