{"id":459203,"date":"2024-10-20T10:02:07","date_gmt":"2024-10-20T10:02:07","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/aecdaily-hm-en-185301-0224\/"},"modified":"2024-10-26T18:35:19","modified_gmt":"2024-10-26T18:35:19","slug":"aecdaily-hm-en-185301-0224","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/aecdaily\/aecdaily-hm-en-185301-0224\/","title":{"rendered":"AECDAILY HM EN 185301 0224"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Slide 1 <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Slide 2: Masonry Anchors and Ties for the 2022 TMS 402 Building Code <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Slide 3 <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Slide 4: How to Use This Online Learning Course <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Slide 5: Purpose and Learning Objectives <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Slide 6: Contents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Slide 7: Introduction <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Slide 8: Introduction <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Slide 9: Introduction <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Slide 10: TMS 402-22 <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Slide 11: TMS 402\/602-22 <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Slide 12: What Version of a Code Must You Use? <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Slide 13: Brief History of TMS 402\/602 <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Slide 14: New Definitions <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Slide 15: Steel Types Allowed <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Slide 16: Stainless Steel Types Allowed <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Slide 17: Nonreferenced New Materials Developed between Code Cycles <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Slide 18: Contract Documents and Calculations <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Slide 19: Architectural Details <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Slide 20: Architectural Details <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Slide 21: Architectural Details <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Slide 22: Always Review Saved Specifications! <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Slide 23: Review Question <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Slide 24: Review Question <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Slide 25: Types of Veneer Anchors <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Slide 26: Types of Veneer Anchors <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Slide 27: Corrugated Sheet-Metal Anchors <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Slide 28: Corrugated Sheet-Metal Anchors <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Slide 29: Corrugated Sheet-Metal Anchors <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Slide 30: Corrugated Sheet-Metal Anchors <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Slide 31: Corrugated Sheet-Metal Anchors <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Slide 32: Corrugated Sheet-Metal Anchors <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Slide 33: Sheet Metal Anchors <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Slide 34: Sheet Metal Anchors <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Slide 35: Corrugated Sheet-Metal vs. Sheet Metal Anchors <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Slide 36: Anchors Must Be Fastened into the Stud <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Slide 37: Unit Wire Anchors and Joint Reinforcement <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | Slide 38: Unit Wire Anchors <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Slide 39: Joint Reinforcement\u00a0 <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Slide 40: Joint Reinforcement\u00a0 <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Slide 41: Joint Reinforcement\u00a0 <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Slide 42: Adjustable Anchors <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Slide 43: Adjustable Anchors <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Slide 44: Adjustable Anchors <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Slide 45: Adjustable Anchors <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Slide 46: Summary: Anchors for Backups <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Slide 47: Stone Anchors <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Slide 48: Stone Anchors <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Slide 49: Review Question <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | Slide 50: Review Question <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Slide 51: Veneer Anchoring Systems: Additional Code Requirements <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Slide 52: Masonry Joint Thickness <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Slide 53: Anchor Spacing <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Slide 54: Drainage Space <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Slide 55: Anchor Embedment in Veneer <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Slide 56: Adhered Veneer <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Slide 57: Adhered Veneer <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | Slide 58: Thermal Bridging Control <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | Slide 59: Thermal Bridging Control <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | Slide 60: Fastening Veneer Anchors to the Backup <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | Slide 61: Seismic Zones and Firewalls <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | Slide 62: Seismic Zones <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | Slide 63: Seismic Zones <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | Slide 64: Fire Testing\u00a0 <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | Slide 65: Firewall Anchors <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | Slide 66: Firewall Anchors <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | Slide 67: Moisture Management in Cavity Walls <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | Slide 68: Moisture Management in Cavity Walls <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | Slide 69: Moisture Management in Cavity Walls <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | Slide 70: Moisture Management: Base of Wall and Flashing <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Slide 71: Moisture Management: Base of Wall and Flashing <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | Slide 72: Moisture Management: Base of Wall and Flashing <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | Slide 73: Moisture Management: Base of Wall and Flashing <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | Slide 74: Moisture Management: Base of Wall and Flashing <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Slide 75: Moisture Management: Base of Wall and Flashing <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | Slide 76: Moisture Management: Drainage Products <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | Slide 77: Moisture Management: Base of Wall and Flashing <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | Slide 78: Review Question <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Slide 79: Review Question <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | Slide 80: What Not to Do! <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | Slide 81: What Not to Do! <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | Slide 82: Incorrect Use of Corrugated Sheet-Metal Anchors <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | Slide 83: Poorly Installed Corrugated Sheet-Metal Anchors <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | Slide 84: Foundation Too Small to Accommodate Thermal Break <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | Slide 85: Wrong Size Pintle Wire <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | Slide 86: Wire Ties Not Attached Correctly <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | Slide 87: Poor On-Site Remedy for Short Ties <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | Slide 88: Poor On-Site Remedy for Long Ties <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | Slide 89: Anchor Not in Plane with Mortar Joint <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | Slide 90: Adhesion Failure <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | Slide 91: Dissimilar Metals <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | Slide 92: Summary <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | Slide 93: Summary <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | Slide 94: Thank You <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Masonry Anchors and Ties for the 2022 TMS 402 Building Code<\/b><\/p>\n |