{"id":65472,"date":"2024-10-17T12:46:50","date_gmt":"2024-10-17T12:46:50","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d5452-2005\/"},"modified":"2024-10-24T18:22:45","modified_gmt":"2024-10-24T18:22:45","slug":"astm-d5452-2005","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d5452-2005\/","title":{"rendered":"ASTM-D5452 2005"},"content":{"rendered":"<\/p>\n
1.1 This test method covers the gravimetric determination by filtration of particulate contaminant in a sample of aviation turbine fuel delivered to a laboratory.<\/p>\n
1.1.1 The sample is filtered through a test membrane and a control membrane using vacuum. The mass change difference identifies the contaminant level per unit volume.<\/p>\n
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.<\/p>\n
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i> For specific hazard statements, see 4.2, 7.3, 7.5, 11.3 and X1.7.2. Before using this standard, refer to supplier’s safety labels, material safety data sheets, and technical literature.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Documents Terminology <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Summary of Test Method Significance and Use Apparatus FIG. 1 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Reagents Sampling FIG. 2 <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Preparation of Apparatus and Sample Containers Preparation of Test and Control Membrane Filters Procedure <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Calculation and Report Precision and Bias Keywords TABLE 1 <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | X1. FILTER MEMBRANE COLOR RATINGS OF AVIATION FUELS BY LABORATORY FILTRATION X1.1 Scope X1.2 Summary of Practice X1.3 Significance and Use X1.4 Apparatus X1.5 Color Standards8 TABLE X1.1 <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | X1.6 Filtration Procedure X1.7 Color Rating Procedure X1.8 Report X2. SAFETY PRECAUTIONS TO AVOID STATIC DISCHARGE X2.1 X2.2 X2.3 <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | X2.4 X2.5 X2.6 X2.7 X3. RECOMMENDED DESIGN FOR SUPPORT APPARATUS X3.1 <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | FIG. X3.1 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" D5452-05 Standard Test Method for Particulate Contamination in Aviation Fuels by Laboratory Filtration<\/b><\/p>\n |