{"id":81144,"date":"2024-10-17T18:51:43","date_gmt":"2024-10-17T18:51:43","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-iso-iec-62271-111-2006\/"},"modified":"2024-10-24T19:45:49","modified_gmt":"2024-10-24T19:45:49","slug":"ieee-iso-iec-62271-111-2006","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-iso-iec-62271-111-2006\/","title":{"rendered":"IEEE ISO IEC 62271 111 2006"},"content":{"rendered":"

– Active. This Standard applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters for rated maximum voltages above 1000 V and up to 38 kV. The following is also included in section 1: In order to simplify this standard where possible, the term recloser\/FI (reclosers\/FIs) has been substituted for automatic circuit recloser or fault interrupter or both. NOTE–When reclosers are applied in substation, special considerations may apply.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEC 62271-111 Front Cover <\/td>\n<\/tr>\n
3<\/td>\nTitle Page <\/td>\n<\/tr>\n
5<\/td>\nContents <\/td>\n<\/tr>\n
7<\/td>\nForeword <\/td>\n<\/tr>\n
10<\/td>\nIEEE Introduction <\/td>\n<\/tr>\n
11<\/td>\n1. Scope
2. References <\/td>\n<\/tr>\n
13<\/td>\n3. Definitions <\/td>\n<\/tr>\n
14<\/td>\n4. Service conditions
4.1 Usual service conditions
4.2 Unusual service conditions <\/td>\n<\/tr>\n
15<\/td>\n5. Rating
5.1 Rating information
5.2 Rated maximum voltage <\/td>\n<\/tr>\n
16<\/td>\n5.3 Rated power-frequency
5.4 Rated continuous current <\/td>\n<\/tr>\n
17<\/td>\n5.5 Rated minimum tripping current…
5.6 Rated symmetrical interrupting current <\/td>\n<\/tr>\n
19<\/td>\n5.7 Rated symmetrical making current
5.8 Rated lightning impulse withstand voltage
5.9 Rated control voltage and ranges
5.10 Rated line and cable charging interrupting currents (where applicable) <\/td>\n<\/tr>\n
25<\/td>\n6. Design tests (type tests)
6.1 General
6.2 Insulation (dielectric) tests <\/td>\n<\/tr>\n
28<\/td>\n6.3 Switching tests <\/td>\n<\/tr>\n
31<\/td>\n6.4 Making current capability
6.5 Rated symmetrical interrupting current tests <\/td>\n<\/tr>\n
42<\/td>\n6.6 Minimum tripping current tests <\/td>\n<\/tr>\n
43<\/td>\n6.7 Partial discharge (corona) tests <\/td>\n<\/tr>\n
44<\/td>\n6.8 Radio influence voltage tests (RIV) <\/td>\n<\/tr>\n
45<\/td>\n6.9 Surge current test; series-trip reclosers\/FIs <\/td>\n<\/tr>\n
46<\/td>\n6.10 Temperature rise test <\/td>\n<\/tr>\n
48<\/td>\n6.11 Time-current tests <\/td>\n<\/tr>\n
49<\/td>\n6.12 Mechanical duty test
6.13 Control electronic elements surge withstand capability (SWC) tests <\/td>\n<\/tr>\n
51<\/td>\n6.14 Condition of recloser\/FI after each test of… <\/td>\n<\/tr>\n
52<\/td>\n7. Production tests (routine tests) <\/td>\n<\/tr>\n
53<\/td>\n7.1 Reclosing and overcurrent trip calibration
7.2 Control, secondary wiring, and accessory devices check tests
7.3 Dielectric withstand test; 1-min. dry power-frequency
7.4 Partial discharge test
7.5 Mechanical operations tests <\/td>\n<\/tr>\n
54<\/td>\n7.6 Water leak test
8. Field tests on units in service, including dc… <\/td>\n<\/tr>\n
55<\/td>\n9. Construction requirements
9.1 Tank construction: submersible or dry vault reclosers\/FIs
9.2 Grounding provisions <\/td>\n<\/tr>\n
56<\/td>\n9.3 Insulating medium quantity indicators
9.4 Oil sampling provision (submersible reclosers\/FIs)
9.5 Manual operating provision
9.6 Position indicator
9.7 Nameplate markings <\/td>\n<\/tr>\n
57<\/td>\n9.8 Stored energy mechanism charge indicator
9.9 Enclosure integrity
9.10 Counters
9.11 Conductor terminal sizes
9.12 Tank construction-pressurized reclosers\/FIs only <\/td>\n<\/tr>\n
58<\/td>\nAnnex A (informative) <\/td>\n<\/tr>\n
60<\/td>\nAnnex B (informative) <\/td>\n<\/tr>\n
63<\/td>\nAnnex C (normative) <\/td>\n<\/tr>\n
65<\/td>\nAnnex D (informative) <\/td>\n<\/tr>\n
69<\/td>\nAnnex E (informative) <\/td>\n<\/tr>\n
72<\/td>\nAnnex F (informative) <\/td>\n<\/tr>\n
73<\/td>\nAnnex G (informative) <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEC 62271-111 Ed.1 (IEEE Std C37.60-2003-Compilation): High Voltage Switchgear and Controlgear Part 111: Overhead, Pad-Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for alternating current systems up to 38 kV<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2006<\/td>\n79<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":81145,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-81144","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/81144","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/81145"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=81144"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=81144"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=81144"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}