{"id":81144,"date":"2024-10-17T18:51:43","date_gmt":"2024-10-17T18:51:43","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-iso-iec-62271-111-2006\/"},"modified":"2024-10-24T19:45:49","modified_gmt":"2024-10-24T19:45:49","slug":"ieee-iso-iec-62271-111-2006","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-iso-iec-62271-111-2006\/","title":{"rendered":"IEEE ISO IEC 62271 111 2006"},"content":{"rendered":"
– Active. This Standard applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters for rated maximum voltages above 1000 V and up to 38 kV. The following is also included in section 1: In order to simplify this standard where possible, the term recloser\/FI (reclosers\/FIs) has been substituted for automatic circuit recloser or fault interrupter or both. NOTE–When reclosers are applied in substation, special considerations may apply.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEC 62271-111 Front Cover <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Title Page <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | IEEE Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1. Scope 2. References <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 3. Definitions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4. Service conditions 4.1 Usual service conditions 4.2 Unusual service conditions <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5. Rating 5.1 Rating information 5.2 Rated maximum voltage <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.3 Rated power-frequency 5.4 Rated continuous current <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.5 Rated minimum tripping current… 5.6 Rated symmetrical interrupting current <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.7 Rated symmetrical making current 5.8 Rated lightning impulse withstand voltage 5.9 Rated control voltage and ranges 5.10 Rated line and cable charging interrupting currents (where applicable) <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6. Design tests (type tests) 6.1 General 6.2 Insulation (dielectric) tests <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 6.3 Switching tests <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 6.4 Making current capability 6.5 Rated symmetrical interrupting current tests <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 6.6 Minimum tripping current tests <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 6.7 Partial discharge (corona) tests <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 6.8 Radio influence voltage tests (RIV) <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 6.9 Surge current test; series-trip reclosers\/FIs <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 6.10 Temperature rise test <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 6.11 Time-current tests <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 6.12 Mechanical duty test 6.13 Control electronic elements surge withstand capability (SWC) tests <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 6.14 Condition of recloser\/FI after each test of… <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 7. Production tests (routine tests) <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 7.1 Reclosing and overcurrent trip calibration 7.2 Control, secondary wiring, and accessory devices check tests 7.3 Dielectric withstand test; 1-min. dry power-frequency 7.4 Partial discharge test 7.5 Mechanical operations tests <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 7.6 Water leak test 8. Field tests on units in service, including dc… <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 9. Construction requirements 9.1 Tank construction: submersible or dry vault reclosers\/FIs 9.2 Grounding provisions <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 9.3 Insulating medium quantity indicators 9.4 Oil sampling provision (submersible reclosers\/FIs) 9.5 Manual operating provision 9.6 Position indicator 9.7 Nameplate markings <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | 9.8 Stored energy mechanism charge indicator 9.9 Enclosure integrity 9.10 Counters 9.11 Conductor terminal sizes 9.12 Tank construction-pressurized reclosers\/FIs only <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | Annex A (informative) <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | Annex B (informative) <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | Annex C (normative) <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | Annex D (informative) <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | Annex E (informative) <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | Annex F (informative) <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | Annex G (informative) <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEC 62271-111 Ed.1 (IEEE Std C37.60-2003-Compilation): High Voltage Switchgear and Controlgear Part 111: Overhead, Pad-Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for alternating current systems up to 38 kV<\/b><\/p>\n |