ASME BPVC I 2013
$377.00
ASME BPVC – I -2013 BPVC Section I, Rules for Construction of Power Boilers
Published By | Publication Date | Number of Pages |
ASME | 2013 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
61 | PG-19 Post Cold‐Forming Strain Limits and Heat‐Treatment Requirements |
62 | PG-20 Post Cold‐Forming Strain Limits And Heat‐Treatment Requirements |
66 | PG-26 Weld Strength Reduction Factors to be Applied When Calculating Maximum Allowable Working Pressure or Minimum Required Thickness of Components Fabricated With a Longitudinal Seam Weld |
70 | PG-28 Maximum Internal Projection of Welded Access or Inspection Openings |
74 | PG-31 Some Acceptable Types of Unstayed Flat Heads and Covers |
79 | PG-33.1 Nomenclature and Equations for Reinforced Openings |
80 | PG-33.2 Some Representative Configurations Describing the Dimensions te, h, and d |
81 | PG-33.3 Chart for Determining Value of F |
83 | PG-38 Illustrations of the Rule Given in PG-38.4 |
84 | PG-39 Minimum Number of Threads Per Connection |
86 | PG-42.1 Welding End Transitions Maximum Envelope |
88 | PG-46.2 Acceptable Proportions for Ends of Through‐Stays |
89 | PG-52.1 Diagram for Determining the Efficiency of Longitudinal and Diagonal Ligaments Between Openings in Cylindrical Shells |
90 | PG-52.2 Example of Tube Spacing with Pitch of Holes Equal in Every Row PG-52.3 Example of Tube Spacing with Pitch of Holes Unequal in Every Second Row PG-52.4 Example of Tube Spacing with Pitch of Holes Varying in Every Second and Third Row |
91 | PG-52.5 Example of Tube Spacing with Tube Holes on Diagonal Lines |
92 | PG-53.3 Diagram for Determining Equivalent Longitudinal Efficiency of Diagonal Ligaments Between Openings in Cylindrical Shells |
94 | PG-58.3.1(a) Code Jurisdictional Limits for Piping — Drum‐Type Boilers |
95 | PG-58.3.1(b) Code Jurisdictional Limits for Piping — Isolable Economizers Located in Feedwater Piping and Isolable Superheaters in Main Steam Piping |
96 | PG-58.3.1(c) Code Jurisdictional Limits for Piping — Reheaters and Nonintegral Separately Fired Superheaters |
97 | PG-58.3.2 Code Jurisdictional Limits for Piping — An Example of Forced‐Flow Steam Generators with no Fixed Steam or Waterline |
98 | PG-58.3.3 Code Jurisdictional Limits for Piping — An Example of Steam Separator Type Forced-Flow Steam Generators with no Fixed Steam or Waterline |
100 | PG-59.1 Typical Boiler Bushings |
102 | PG-60.3.7 Y‐Type Globe Valve |
103 | PG-60.3.9 Typical Arrangement of Steam and Water Connections for a Water Column |
106 | PG-67.4 Requirements for Overpressure Protection Forced‐Flow Steam Generator |
109 | PG-68.7 Superheat Correction Factor, Ksh |
111 | PG-68.7M Superheat Correction Factor, Ksh |
114 | PG-69.2.3 Supercritical Correction Factor, Ksc |
116 | PG-69.2.3M Supercritical Correction Factor, Ksc |
124 | PG-80 Maximum Permissible Deviation from a Circular Form, e, for Cylindrical Parts Under External Pressure |
127 | PG-105.1 Official Certification Mark to Denote the American Society of Mechanical Engineers’ Standard for Boilers |
129 | PG-106 Form of Stamping |
137 | PW-9.1 Butt Welding of Plates of Unequal Thickness |
138 | PW-9.2 Prohibited Welded Joint |
139 | PW-11 Required Volumetric Examination of Welded Butt Joints |
140 | PW-15 Examples of Weld Strength Calculations |
142 | PW-16.1 Some Acceptable Types of Welded Nozzles and Other Connections to Shells, Drums, and Headers |
146 | PW-16.2 Some Acceptable Forms of Welds for Lugs, Hangers, and Brackets on Shells, Drums, and Headers |
147 | PW-19.4(a) Some Acceptable Types of Diagonal Braces for Installation by Welding |
148 | PW-19.4(b) Unacceptable Types of Diagonal Braces for Installation by Welding |
150 | PW-33 Alignment Tolerance of Sections to be Butt Welded |
152 | PW-39-1 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 1 |
153 | PW-39-2 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 3 |
154 | PW-39-3 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 4 |
155 | PW-39-4 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 5A |
156 | PW-39-5 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 15E |
157 | PW-39-6 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 6 |
158 | PW-39-7 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 7 PW-39-8 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 8 |
159 | PW-39-9 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 10H PW-39-10 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 10I |
160 | PW-39-11 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 31 PW-39-12 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 43 |
161 | PW-39-13 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 45 PW-39-14 Mandatory Requirements for Postweld Heat Treatment of Pressure Parts and Attachments — P-No. 51 |
162 | PW-39.1 Alternate Postweld Heat Treatment Requirements for Carbon and Low Alloy Steels |
165 | PW-43.1 Method of Computation of Attachments to Tubes PW-43.1 Tube Attachment Angle Design Factor, K |
166 | PW-43.2 Chart for Determining Load Factor, Lf |
171 | PW-53.1 Test Specimens from Longitudinal Welded Test Plates |
172 | PW-53.2 Method of Forming Longitudinal Test Plates |
173 | PW-53.3(a) Details of Tension Test Specimens |
174 | PW-53.3(b) Details of Bend Test Specimens |
177 | PR-9-1 Minimum Thickness of Buttstraps |
178 | PR-13-1 Typical Plate Edge Beveled for Sealing by Calking in a Riveted Joint |
179 | PR-15.4-1 Location of Seams in Inside and Outside Calking Boundaries PR-15.3-1 Allowable Stress on Rivets in Tension |
180 | PR-17.2-1 Boundary of Reinforcing Plate on Outside and Inside of Drum |
181 | PR-20.2-1 Allowable Welding of Plate Edges at Ends of Buttstraps |
184 | PB-1 Maximum Design Temperatures [°F (°C)] for Brazing Filler Metal |
185 | PB-15 Some Acceptable Types of Brazed Joints |
186 | PB-16 Recommended Joint Clearance at Brazing Temperature |
190 | PWT-11 Examples of Acceptable Forms of Tube Attachment |
191 | PWT-12.1 Box‐Type Header Joint PWT-12.2 Method of Forming Waterleg Joints by Welding |
193 | PFT-12.1 Some Acceptable Forms of Tube Attachment on Firetube Boilers |
195 | PFT-17.2 Acceptable Type of Ring‐Reinforced Furnace |
196 | PFT-18.1 Morison Furnace |
197 | PFT-19 Connection Between Plain and Corrugated Furnace PFT-20 Welding Ogee Ring |
198 | PFT-21 Some Acceptable Methods of Forming Waterleg Joints by Welding |
199 | PFT-23.1 Stayed Wrapper Sheet of Locomotive‐Type Boiler |
200 | PFT-25 Example of Staying of Heads Adjacent to Cylindrical Furnaces |
201 | PFT-27 Pitch of Staybolts Adjacent to Upper Corners of Fireboxes |
203 | PFT-32 Measurements for Determining Stresses in Diagonal Stays |
205 | PFT-46.1 Spacing and Weld Details for Wall‐Support Lugs Set in Pairs on Horizontal‐Return Tubular Boilers |
206 | PFT-46.2 Welded Bracket Connection for Horizontal‐Return Tubular Boilers |
215 | PVG-12 Constant, C, for Vapor Related to Ratio of Specific Heats (k = cp/cv) |
218 | PHRSG-4 Some Acceptable Desuperheater Spraywater Protection Device Arrangements |
219 | PHRSG-4 Minimum Drain Pot Size |
223 | III-1A Certificate of Conformance for Reapplication of the Certification Mark |
224 | Guide for Completing the Certificate of Conformance for Reapplication of the Certification Mark |
280 | P-2 Manufacturer’s Data Report for all Types of Boilers |
284 | P-2A Manufacturer’s Data Report for all Types of Electric Boilers |
289 | P-2B Manufacturer’s Data Report for Electric Superheaters and Reheaters |
293 | P-3 Manufacturer’s Data Report for Watertube Boilers, Superheaters, Waterwalls, and Economizers |
298 | P-3A Engineering-Contractor Data Report for a Complete Boiler Unit |
301 | P-4 Manufacturer’s Partial Data Report |
304 | P-4A Manufacturer’s Data Report for Fabricated Piping |
307 | P-4B Manufacturer’s Data Report for Field Installed Mechanically Assembled Piping |
309 | P-5 Summary Data Report for Process Steam Generators |
311 | P-6 Manufacturer’s Data Report Supplementary Sheet |
312 | P-7 Manufacturer’s Data Report for Pressure Relief Valves |
316 | P-8 Manufacturer’s or Assembler’s Certificate of Conformance for Pressure Relief Valves |
341 | INTERPRETATIONS Volume 62 |