ASTM-E261:2010 Edition
$44.96
E261-10 Standard Practice for Determining Neutron Fluence, Fluence Rate, and Spectra by Radioactivation Techniques
Published By | Publication Date | Number of Pages |
ASTM | 2010 | 14 |
1.1 This practice describes procedures for the determination of neutron fluence rate, fluence, and energy spectra from the radioactivity that is induced in a detector specimen.
1.2 The practice is directed toward the determination of these quantities in connection with radiation effects on materials.
1.3 For application of these techniques to reactor vessel surveillance, see also Test Methods E1005 .
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Note 1Detailed methods for individual detectors are given in the following ASTM test methods: E262 , E263 , E264 , E265 , E266 , E343 , E393 , E481 , E523 , E526 , E704 , E705 , and E854 .
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents |
2 | Terminology Summary of Practice Significance and Use Counting Apparatus Requirements for Activation-Detector Materials Irradiation Procedures Calculation |
5 | TABLE 1 |
7 | TABLE 2 |
8 | TABLE 3 |
9 | Report Precision and Bias Keywords A1. NEUTRON FLUENCE CONVENTIONS FOR THERMAL AND EPITHERMAL NEUTRONS A1.1 Background |
10 | A1.2 Calculation of Reaction Rates |
12 | A1.3 Conversion Formulae Between Fluence Conventions |
13 | REFERENCES |